Timing Adjustment Style Timing Adjustment Style |
---|
![]() | ![]() |
Trippers | Push Button |
Maximum On/Off Cycles Maximum On/Off Cycles |
---|
|
|
Specifications Met Specifications Met |
---|
|
Environment Environment |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | Screw Terminals |
![]() | Screw-Clamp Terminals |
![]() | Quick- Disconnect Terminals |
Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. Switches cannot be sold to California due to local energy efficiency requirements.
24-hour switches repeat the same program daily.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Environment | Cannot Be Sold To | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | ||||||||||||||||||
1 | 20 A @ 120 V AC, 208 V AC, 240 V AC, 277 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 0000000 | __ | 000000 | 00 |
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 00000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 00000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 00000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | ||||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. Switches cannot be sold to California due to local energy efficiency requirements.
24-hour switches repeat the same program daily.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Cannot Be Sold To | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | ||||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | SPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | CA | 0000000 | 0000000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | CA | 0000000 | 00000 | __ | 000000 | 00 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | ||||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | CA | 0000000 | 000000 | 1 | 0000000 | 0000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily.
Switches with trippers are programmed by setting on and off times by positioning trippers around the clock dial.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Ht. | Wd. | Dp. | Plug Type | Each | |
24-Hour Timing Cycle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 per Day | 30 min. | Trippers | Removable | 6 | 15 A @ 120 V AC | 1 | 3 1/4" | 3 1/4" | 3 1/4" | Three Prong | 0000000 | 000000 |
Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Switches with light sensor control allow one device to be controlled by the presence or absence of light.
NEMA 3R rated switches are protected against falling liquids and light splashing.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Cannot Be Sold To | Each | |
24-Hour Timing Cycle—NEMA 3R | ||||||||||||||||||
12 per Day | 30 min. | Trippers | Removable | 4 | 15 A @ 120 V AC | 2 | Light Sensor Control | 9 3/8" | 5 1/2" | 3 3/8" | Three Prong | 2 | No | 4 | 1/4" | CA | 0000000 | 0000000 |
Additional Trippers (Pkg. of 2 Pair) | 0000000 | Pkg. | 00000 |
Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards. They cannot be sold to California due to local energy efficiency requirements.
24-hour switches repeat the same program daily.
For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Specifications Met | Cannot Be Sold To | Each | |
24-Hour Timing Cycle | |||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | CA | 0000000 | 000000 |
Mount these switches to a flat surface or attach to DIN rail. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. Switches are UL listed, C-UL listed, and CE marked as compliant with safety standards in the U.S., Canada, and Europe. They cannot be sold to California due to local energy efficiency requirements.
24-hour switches repeat the same program daily.
Mounting | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Cannot Be Sold To | Each | |
24-Hour Timing Cycle | |||||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | SPDT | 4.2" | 2.8" | 2.2" | No | 3 | 0.13" | 35 | Screw Terminals | CSA Certified, CE Marked, C-UL Recognized Component, UL Recognized Component | CA | 0000000 | 000000 |
Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily.
Mounting | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Wire Connection Type | Cannot Be Sold To | Each | |
24-Hour Timing Cycle | ||||||||||||||||
With Battery Backup, Lockout | ||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | CA | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | CA | 0000000 | 000000 |
Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
Mounting | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | For DIN Rail Ht., mm | Ht. | Wd. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||||
2 | 15 A @ 250 V AC | 120V AC/240V AC | 12 per Day | 1 min. | Push Button | SPST-NO | 3.8" | 3.8" | 2.2" | No | 2 | 35 | 3.62" | 3.62" | Screw Terminals | 00000000 | 0000000 |
Remotely program these switches via bluetooth signal with a smartphone, tablet, or PC to turn a device on and off at a set time and day. They’re often used with lighting, pumps, and filters. All have a 24-hour/seven-day/365-day timing cycle that can repeat the same program daily or perform a different program each day of the week or year. They compensate for leap year and daylight savings time. A PIN code is required to prevent unauthorized tampering with settings. All have an override to bypass the programmed on/off settings.
Two-circuit switches can apply a different program to each circuit. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | For DIN Rail Ht., mm | Wire Connection Type | Environmental Rating | Each | |
24-Hour/7-Day/365-Day Timing Cycle | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 15 A @ 120 V AC, 10 A @ 240 V AC | 120V AC/240V AC | 100 per Day | 1 min. | Push Button | SPDT | 3 1/2" | 1 3/8" | 2 3/8" | 35 | Screw-Clamp Terminals | IP20 | 0000000 | 0000000 |
2 | 15 A @ 120 V AC, 10 A @ 240 V AC | 120V AC/240V AC | 500 per Day | 1 min. | Push Button | SPDT | 3 1/2" | 1 3/8" | 2 3/8" | 35 | Screw-Clamp Terminals | IP20 | 0000000 | 000000 |