McMaster-Carr logo
    Filter by
    Maximum Outlet Vacuum
    Outlet Pipe Size
    Industrial Info Compare
    Inlet Thread Type
    Body Material
    Actuation
    Thread Type
    Industrial Info Compare
    Inlet Connection
    Gauge Port Thread Type
    Fitting Connection
    Inlet Gender
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    32 Products

    Extended-Life Vacuum-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Vacuum-Regulating Valves. Extended-Life Vacuum-Regulating Valves for Air and Inert Gas.
    For a longer service life than brass vacuum-regulating valves, these are made of bronze for strength and durability. They throttle a high vacuum source to maintain a lower vacuum level in your system. Turning the adjustment screw will adjust the vacuum setting.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Vacuum Range,
    in. Hg
    Vacuum Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Each
    NPT Female
     
    Bronze Body—Neoprene Diaphragm and Chrome-Plated Bronze Seal
    1/2
    Side1/2
    Side2 to 30Screw2 7/8"Air, Inert Gas-20 to 1804710K110000000
    3/4
    Side3/4
    Side2 to 30Screw2 7/8"Air, Inert Gas-20 to 1804710K13000000
    1
    Side1
    Side2 to 30Screw4 1/2"Air, Inert Gas-20 to 1804710K1500000000
    1 1/4
    Side1 1/4
    Side2 to 30Screw4 1/2"Air, Inert Gas-20 to 1804710K1700000000
    1 1/2
    Side1 1/2
    Side8 to 30Screw5 3/4"Air, Inert Gas-20 to 1804710K1800000000
    2
    Side2
    Side8 to 30Screw5 3/4"Air, Inert Gas-20 to 1804710K1900000000
     

    Adjustable Vacuum-Relief Valves for Air and Inert Gas

    Image of Product. Front orientation. Vacuum-Relief Valves. Adjustable Vacuum-Relief Valves for Air and Inert Gas.
    These valves begin opening at the set vacuum level and fully open at about 10% over the set point. They begin closing as the vacuum level drops and fully close when the system is restored below the set point. Adjust the set vacuum level within the range. Valves have a vented relief port to exhaust discharge directly.
    Inlet
    Vacuum Set Point
    Pipe
    Size
    Location
    Relief Port
    Location
    Range,
    in. Hg
    Adjustment Method
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Each
    NPT Male Inlet and Vacuum Relief Vent
     
    Brass Body—440C Stainless Steel Seal
    1/4
    BottomTop0 to 27External Adjustment Screw1 3/4"Air, Inert Gas-15 to 25048935K2500000
     
    Brass Body—Buna-N Seal
    3/8
    BottomTop0 to 27External Adjustment Screw2 1/16"Air, Inert Gas-15 to 25048935K3500000
    3/4
    BottomTop0 to 27External Adjustment Screw2 5/8"Air, Inert Gas-15 to 25048935K4500000
     

    Vacuum-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Vacuum-Regulating Valves. Vacuum-Regulating Valves for Air and Inert Gas.
    Throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. All valves have a gauge port.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Vacuum Range,
    in. Hg
    Vacuum Adjustment
    Method
    Vacuum Gauge
    Included
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Each
    NPT Female
     
    Brass Body—EPM Rubber Diaphragm and Buna-N Seal
    1/4
    Bottom1/4
    Side0 to 15ScrewNo1 3/4"Air, Carbon Dioxide, Inert Gas, Nitrogen-20 to 1805021K140000000
    1/4
    Bottom1/4
    Side10 to 30ScrewNo1 3/4"Air, Carbon Dioxide, Inert Gas, Nitrogen-20 to 1805021K24000000
     

    High-Accuracy Panel-Mount Vacuum-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Vacuum-Regulating Valves. High-Accuracy Panel-Mount Vacuum-Regulating Valves for Air and Inert Gas.
    For precise control over your vacuum level, these valves have ±0.1% accuracy. They throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have a gauge port. They are constant-bleed style, so they continually release small amounts of process gas to improve accuracy and repeatability.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Vacuum Range,
    in. Hg
    Vacuum Adjustment
    Method
    Vacuum Gauge
    Included
    End-to-End
    Lg.
    Bleed Type
    Panel Cutout
    Dia.
    For Use With
    Temp. Range,
    ° F
    Each
    NPT Female
     
    Brass Body—Buna-N Diaphragm and Buna-N Seal
    1/8
    Side1/8
    Side0 to 25KnobNo2 1/8"Constant Bleed1 3/8"Air, Argon, Nitrogen-40 to 1654640T710000000
    1/4
    Side1/4
    Side0 to 25KnobNo2 1/8"Constant Bleed1 3/8"Air, Argon, Nitrogen-40 to 1654640T72000000
     

    Vacuum Breakers

    Also known as vacuum-breaking valves, these valves have vents that open when pressure drops to relieve vacuum conditions and prevent backward suction from drawing liquid into upstream piping.
    90° Elbow
    Image of Product. Front orientation. Contains Annotated. Vacuum Breakers. Vacuum Breakers, 90° Elbow.
    Elbows are designed for intermittent flow. They discharge liquid directly and should not be installed in areas where spillage could cause damage.
    Chrome-Plated Bronze Body—Chrome-plated bronze valves are more corrosion resistant than brass valves.
    Brass Body
    Chrome-Plated
    Bronze Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Port-to-Port
    Lg.
    Seal Material
    For Use
    With
    Each
    Each
    NPT Female Inlet × NPT Female Outlet
    1/4
    1/4
    125 psi @ 70° F35 to 1801"Silicone Rubber
    Water———09903K31000000
    3/8
    3/8
    125 psi @ 70° F35 to 1801"Silicone Rubber
    Water———09903K3300000
    1/2
    1/2
    125 psi @ 70° F35 to 1801 1/4"Silicone Rubber
    Water———09903K3500000
    1/2
    1/2
    125 psi @ 70° F35 to 1801 5/16"Silicone Rubber
    Water47685K12000000———0
    3/4
    3/4
    125 psi @ 70° F35 to 1801 1/2"Silicone Rubber
    Water47685K34000009903K3700000
    1
    1
    125 psi @ 70° F35 to 1801 5/8"Silicone Rubber
    Water47685K3600000———0
    1 1/4
    1 1/4
    125 psi @ 70° F35 to 1802"Silicone Rubber
    Water47685K44000000———0
    1 1/2
    1 1/2
    125 psi @ 70° F35 to 1802 1/4"Silicone Rubber
    Water47685K46000000———0
    2
    2
    125 psi @ 70° F35 to 1802 3/4"Silicone Rubber
    Water47685K48000000———0
     
    Straight
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers, Straight.
    Straights are often used with steam coils, heat exchangers, and space heaters.
    Brass Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    End-to-End
    Lg.
    Seal
    Material
    For Use With
    Each
    NPT Male Inlet × NPT Female Outlet
    1/2
    3/8
    300 psi @ 70° F-20 to 3651 3/4"EPM RubberAir, Argon, Helium, Krypton, Neon, Steam, Water, Xenon4817K140000000
    3/4
    1/2
    300 psi @ 70° F-20 to 3652 1/8"EPM RubberAir, Argon, Helium, Krypton, Neon, Steam, Water, Xenon4817K15000000
    1
    3/4
    300 psi @ 70° F-20 to 3652 3/8"EPM RubberAir, Argon, Helium, Krypton, Neon, Steam, Water, Xenon4817K16000000
     

    Vacuum Breakers with Garden-Hose Fittings

    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers with Garden-Hose Fittings, Set Screw.

    Set Screw

    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers with Garden-Hose Fittings, Tamper-Resistant Set Screw.

    Tamper-Resistant

    Set Screw

    Prevent dirty, contaminated water from backing up into your garden hose line—install these vacuum breakers between a faucet and a garden hose. Also known as vacuum-breaking valves, these valves have a built-in check valve that blocks backflow, so you can leave your hose in a utility sink full of dirty water without the water going back into the line.
    When the check valve is closed, it has vents that open to release the water. This reduces pressure in the line and confirms the valve is working. Because these valves vent water, use them in environments where spilled water won’t cause a problem. This design adheres to ASSE Standard 1011 for valves with a vent.
    Mount valves to faucet outlets with a set screw, and easily thread or unthread a hose while the valves stay in place.
    Valves comply with Uniform Plumbing Code (UPC) and are CSA certified, so they're safe to use in sanitary plumbing systems because they prevent contamination from flowing backward into your line.
    These valves are designed to be used intermittently. They've been tested under ASME A112.1.3, which assumes the valves will not be used for more than 12 hours at a time.
    Tamper-Resistant Set Screw—Valves with tamper-resistant set screws have a head that breaks off after tightening to prevent valve removal after installation.
    NSF/ANSI 372—Valves that meet NSF/ANSI Standard 372 are certified lead free.
    Chrome-Plated Brass Body—Chrome-plated brass valves are more corrosion resistant than plain brass valves.
    Brass Body
    Chrome-Plated Brass Body
    Inlet Hose
    Size
    Outlet
    Hose Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    End-to-End
    Lg.
    Food Industry
    Std.
    Specs. Met
    Certification
    Seal
    Material
    For Use
    With
    Temp. Range,
    ° F
    Each
    Temp. Range,
    ° F
    Each
    GHT Female Inlet × GHT Male Outlet
     
    Set Screw
    3/43/4Not Rated125 psi @ 70° F1 1/2"ASME A112.1.3, ASSE 1001, ASSE 1011, CAN/CSA-B64.2, UPC CompliantCSA Certified
    IAPMO Listed
    Rubber
    Water30 to 18046605K5500000030 to 18046605K58000000
    3/43/4Not Rated125 psi @ 70° F1 1/2"NSF/ANSI 372
    ASME A112.1.3, ASSE 1001, ASSE 1011, CAN/CSA-B64.2, UPC CompliantCSA Certified
    IAPMO Listed
    Rubber
    Water———030 to 18046605K1300000
     
    Tamper-Resistant Set Screw
    3/43/4Not Rated125 psi @ 70° F1 1/2"ASME A112.1.3, ASSE 1001, ASSE 1011, CAN/CSA-B64.2, UPC CompliantCSA Certified
    IAPMO Listed
    Rubber
    Water30 to 18046605K750000030 to 18046605K8500000
    3/43/4Not Rated125 psi @ 70° F1 1/2"NSF/ANSI 372
    ASME A112.1.3, ASSE 1001, ASSE 1011, CAN/CSA-B64.2, UPC CompliantCSA Certified
    IAPMO Listed
    Rubber
    Water33 to 18046605K12100000———0
     
    back to top