For Bulb Wattage For Bulb Wattage |
---|
For Bulb Trade Number For Bulb Trade Number |
---|
Light Technology Light Technology |
---|
|
Light Setting Light Setting |
---|
|
Ballast Type Ballast Type |
---|
|
System of Measurement System of Measurement |
---|
|
Length Length |
---|
|
|
|
Depth Depth |
---|
|
|
|
Specifications Met Specifications Met |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Power Source Power Source |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
![]() | Hardwire |
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Output Voltage Output Voltage |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Replacing a Ballast
More
Electronic Ballasts for Tubular Fluorescent Light Bulbs

In addition to being more energy-efficient than magnetic ballasts, these electronic ballasts are lighter and quieter. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Instant-start ballasts turn on immediately. They are the most energy-efficient, but shorten the bulb's life.
Rapid-start ballasts have a slight turn-on delay, but are gentler on bulbs than instant-start ballasts so bulbs last longer.
Programmed-start ballasts provide the longest bulb life, but they take longer than instant- and rapid-start ballasts to turn on. They are often used with motion-sensing light controls.
For Bulb Trade No. | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Each | |
Instant Start | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tubular T8 Bulbs | ||||||||||||
F17T8, F25T8, F32T8 | 1 | 17W, 25W, 32W | 120V/277V | 4 | Not Dimmable | 9 1/2" | 1 1/8" | 1 1/8" | 0° | UL Listed | 0000000 | 000000 |
F17T8, F25T8, F32T8 | 3, 4 | 17W, 25W, 32W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F17T8, F25T8, F32T8, F40T8 | 1, 2 | 17W, 25W, 32W, 40W | 120V/277V | 5 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F25T8, F32T8 | 2, 3 | 25W, 32W | 120V/277V | 6 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F96T8 | 2 | 59W | 120V/277V | 5 | Not Dimmable | 9 1/2" | 1 1/4" | 1" | 32° | UL Listed | 0000000 | 00000 |
For Tubular T12 Bulbs | ||||||||||||
F72T12, F96T12 | 1, 2 | 55W, 75W | 120V/277V | 5 | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | 0° | UL Listed | 0000000 | 00000 |
For U-Shaped T8 Bulbs | ||||||||||||
FB32T8, FBO16, FBO24, FBO31, FBO32 | 1, 2 | 16W, 24W, 31W, 32W | 120V/277V | 5 | Not Dimmable | 9 1/2" | 1 5/8" | 1 1/8" | -20° | UL Listed | 0000000 | 00000 |
Rapid Start | ||||||||||||
For Tubular T12 Bulbs | ||||||||||||
F30T12, F34T12, F40T12 | 2 | 30W, 34W, 40W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 50° | UL Listed | 0000000 | 00000 |
For Tubular T12/HO Bulbs | ||||||||||||
F48T12/HO, F60T12/HO, F72T12/HO, F96T12/HO | 1, 2 | 60W, 75W, 85W, 110W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | -20° | UL Listed | 0000000 | 00000 |
Programmed Start | ||||||||||||
For Tubular T5 Bulbs | ||||||||||||
F14T5, F21T5, F28T5, F35T5 | 1, 2 | 14W, 21W, 28W, 35W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
FP54T5/HO, FPC55, FT55DL, L58T8 | 2 | 54W | 120V/277V | 11 | Dimmable | 16 3/4" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 000000 |
For Tubular T5/HO Bulbs | ||||||||||||
F24T5/HO, F39T5/HO, FP24/HO, FP39/HO | 1, 2 | 24W, 39W | 120V/277V | 8 | Not Dimmable | 14 1/4" | 1 1/4" | 7/8" | -20° | UL Listed | 0000000 | 00000 |
F54T5/HO | 3, 4 | 54W | 120V/277V | 15 | Not Dimmable | 16 3/4" | 1 3/4" | 1 1/4" | -20° | UL Listed | 0000000 | 00000 |
F54T5/HO, FP54/HO | 1, 2 | 54W | 120V/277V | 8 | Not Dimmable | 16 3/4" | 1 1/4" | 1" | -20° | UL Listed | 00000000 | 00000 |
For Tubular T8 Bulbs | ||||||||||||
F17T8, F25T8, F32T8 | 1 | 17W, 25W, 32W | 120V/277V | 6 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F17T8, F25T8, F32T8 | 2 | 17W, 25W, 32W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
FBO31, FBO32, FO32 | 1 | 32W | 120V/277V | 8 | Dimmable | 9 1/2" | 1 3/4" | 1" | 50° | UL Listed, Meets Federal Minimum Efficiency Standards | 0000000 | 00000 |
FBO31, FBO32, FO32 | 2 | 32W | 120V/277V | 11 | Dimmable | 9 1/2" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 00000 |
FBO31, FBO32, FO32 | 3 | 32W | 120V/277V | 14 | Dimmable | 16 3/4" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 00000 |
FBO31, FBO32, FO32 | 4 | 32W | 120V/277V | 17 | Dimmable | 16 3/4" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 00000 |
For Tubular T8/HO Bulbs | ||||||||||||
F96T8/HO | 1, 2 | 86W | 120V/277V | 8 | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | -20° | UL Listed | 0000000 | 00000 |
Magnetic Ballasts for Tubular Fluorescent Light Bulbs

These ballasts are often found in older installations. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Preheat ballasts take several seconds to turn on and require a starter. Ballasts with a built-in starter are more efficient than other preheat ballasts.
Rapid-start ballasts have a slight turn-on delay, but are quicker than preheat ballasts.
Ballasts that cannot be sold to Canada do not meet local efficiency standards.
Ballasts | Starters | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Bulb Trade No. | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Cannot Be Sold To | Each | Each | ||
Preheat Start | |||||||||||||||
For Tubular T12 and T8 Bulbs | |||||||||||||||
F15T8, F20T12 | 1 | 15W, 20W | 120V | 2 | Not Dimmable | 3 1/8" | 1 3/8" | 1 7/8" | 50° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00000 |
For Tubular T5 Bulbs | |||||||||||||||
F4T5, F6T5, F8T5 | 1 | 4W, 6W, 8W | 120V | 2 | Not Dimmable | 3 1/8" | 1 3/8" | 1 7/8" | 50° | UL Listed | Canada | 00000000 | 00000 | 000000 | 0000 |
Preheat Start with Built-In Starter | |||||||||||||||
For Tubular T12 and T8 Bulbs | |||||||||||||||
F13T8, F14T12, F15T12, F15T8, F20T12 | 1 | 14W, 15W, 20W | 120V | 5 | Not Dimmable | 6 1/2" | 2" | 1 3/8" | 50° | UL Listed | Canada | 00000000 | 00000 | 000000 | 00 |
F13T8, F15T12, F15T8, F20T12 | 2 | 15W, 20W | 120V | 8 | Not Dimmable | 6 1/2" | 2 3/8" | 1 1/2" | 50° | UL Listed | Canada | 00000000 | 00000 | 000000 | 00 |
Rapid Start | |||||||||||||||
For Circline T9 Bulbs | |||||||||||||||
FC12T9, FC16T9 | 1 | 32W, 40W | 120V | 6 | Not Dimmable | 6 1/2" | 2" | 1 3/8" | 50° | UL Listed | __ | 0000000 | 00000 | 000000 | 00 |
FC6T9, FC8T9 | 1 | 20W, 22W | 120V | 6 | Not Dimmable | 6 1/2" | 2" | 1 3/8" | 50° | UL Listed | __ | 0000000 | 00000 | 000000 | 00 |
For Tubular T12/VHO Bulbs | |||||||||||||||
F48T12/VHO, F72T12/VHO | 1, 2 | 116W, 168W | 120V | 8 | Not Dimmable | 14 3/8" | 3 1/4" | 2 5/8" | -20° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00 |
F48T12/VHO, F72T12/VHO | 1, 2 | 116W, 168W | 277V | 8 | Not Dimmable | 14 3/8" | 3 1/4" | 2 5/8" | -20° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00 |
F72T12/VHO, F96T12/VHO | 2 | 168W, 215W | 120V | 8 | Not Dimmable | 14 3/8" | 3 1/4" | 2 5/8" | -20° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00 |
F72T12/VHO, F96T12/VHO | 2 | 168W, 215W | 277V | 8 | Not Dimmable | 14 3/8" | 3 1/4" | 2 5/8" | -20° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00 |
Starters for Tubular Fluorescent Light Bulbs

Replace or add starters in preheat magnetic ballasts.
LED Drivers

Send electricity to LED lights while protecting them from voltage and current fluctuations. These drivers convert high-voltage, alternating current from your power supply into low-voltage, direct current. Use them to replace existing LED drivers or build your own light fixtures. All meet U.S. and Canadian safety standards, as well as UL requirements for use in dry and damp locations. They’re also FCC compliant to meet regulations for electromagnetic interference.
Drivers that are not for use outdoors power indoor lights. Linear drivers pair with ceiling strip lights, which are common in offices and storage rooms. Use them to replace fluorescent strip lights for more energy-efficient and longer-lasting lighting. Downlight drivers create directed, ambient lighting, so they’re often used for offices, lobbies, and decorative lighting. They work well with recessed ceiling can lights and downlight wall sconces.
Drivers that are for use outdoors help light roadways and parking garages. They’re often used with area, flood, bay, and security lights, as well as with signage.
Constant-current drivers ensure a reliable output from your fixture and prevent it from degrading quickly due to current fluctuations and receiving too much power. They’re the most common type of LED driver.
Constant-voltage drivers send a consistent voltage output to exactly match the light’s required voltage. They’re useful for signs and cabinet lights.
Drivers with constant current and voltage provide both functions at the same time. Drivers with constant current or constant voltage only perform one of those functions at a time.
Programmable drivers let you set their output current and voltage to match the power requirements of your light. They’re good to have on hand when you don’t know which drivers you’ll have to replace.
For technical drawings and 3-D models, click on a part number.
Output | Input | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Light Setting | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
347-480V AC Input Voltage | |||||||||||||
70-210V DC | 1.25-0.1 | 180W | Wire Leads | 0.56-0.40 | 200W | Wire Leads | Dimmable | 9 1/2" | 2 5/16" | 1 1/2" | -40° to 130° | 00000000 | 0000000 |
Output | Input | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | ||||||||||||
35-48V DC | 0.55 | 27W | Wire Leads | 0.28-0.14 | 32W | Wire Leads | 9 1/2" | 1 3/8" | 1 1/8" | 0° to 120° | 00000000 | 000000 |
35-48V DC | 0.75 | 36W | Wire Leads | 0.36-0.16 | 45.7W | Wire Leads | 9 1/2" | 1 3/8" | 1 1/8" | 0° to 120° | 00000000 | 00000 |
35-48V DC | 0.825 | 40W | Wire Leads | 0.40-0.18 | 47.1W | Wire Leads | 9 1/2" | 1 3/8" | 1 1/8" | 0° to 120° | 00000000 | 00000 |
Output | Input | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Light Setting | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | |||||||||||||
14-42V DC | 1.05 | 44W | Wire Leads | 0.46-0.21 | 56W | Wire Leads | Dimmable | 5 15/16" | 1 13/16" | 1 1/8" | -40° to 130° | 00000000 | 0000000 |
25-50V DC | 1.5 | 75W | Wire Leads | 0.70-0.30 | 86W | Wire Leads | Dimmable | 6 5/8" | 2 5/16" | 1 1/2" | -40° to 130° | 00000000 | 00000 |
44-140V DC | 1.05 | 150W | Wire Leads | 1.40-0.60 | 169W | Wire Leads | Dimmable | 9 1/2" | 2 3/8" | 1 1/2" | -40° to 130° | 00000000 | 000000 |
347-480V AC Input Voltage | |||||||||||||
42-142V DC | 1.05 | 150W | Wire Leads | 0.50-0.35 | 164W | Wire Leads | Dimmable | 9 1/2" | 2 5/16" | 1 1/2" | -40° to 130° | 00000000 | 000000 |
Output | Input | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | ||||||||||||
12V DC | 0.1-5 | 60W | Wire Leads | 0.60-0.29 | 70W | Wire Leads | 9 1/2" | 1 3/4" | 1 1/16" | -40° to 130° | 00000000 | 0000000 |
Output | Input | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | ||||||||||||
24V DC | 2.2 | 53W | Wire Leads | 0.50-0.25 | 62W | Wire Leads | 9 7/16" | 1 3/4" | 1 1/8" | -40° to 130° | 00000000 | 0000000 |
Output | Input | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | ||||||||||||
24V DC 12-24V DC | 3.2 3.2-0.1 | 77W | Wire Leads | 0.74-0.32 | 90W | Wire Leads | 9 1/2" | 1 3/4" | 1 1/8" | -40° to 130° | 00000000 | 000000 |
24V DC 12-24V DC | 4.1 4.1-0.1 | 100W | Wire Leads | 0.95-0.40 | 115W | Wire Leads | 9 1/2" | 1 3/4" | 1 1/8" | -40° to 130° | 00000000 | 000000 |
Output | Input | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Light Setting | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | |||||||||||||
12-40V DC | 1.2-0.1 | 30W | Wire Leads | 0.31-0.14 | 35W | Wire Leads | Dimmable | 6 5/8" | 1 3/4" | 1 1/8" | -40° to 130° | 00000000 | 000000 |
18-54V DC | 1.8-0.1 | 55W | Wire Leads | 0.55-0.24 | 66W | Wire Leads | Dimmable | 6 5/8" | 1 3/4" | 1 1/8" | -40° to 130° | 00000000 | 00000 |
48-143V DC | 1.1-0.1 | 100W | Wire Leads | 0.94-0.42 | 114W | Wire Leads | Dimmable | 9 1/2" | 2 3/8" | 1 1/2" | -40° to 130° | 00000000 | 00000 |
70-210V DC | 1.25-0.1 | 180W | Wire Leads | 1.87-0.72 | 198W | Wire Leads | Dimmable | 9 1/2" | 2 3/8" | 1 1/2" | -40° to 130° | 00000000 | 00000 |
100-285V DC | 0.9-0.1 | 180W | Wire Leads | 1.87-0.72 | 198W | Wire Leads | Dimmable | 9 1/2" | 2 3/8" | 1 1/2" | -40° to 130° | 00000000 | 00000 |
Output | Input | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Light Setting | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | |||||||||||||
10-54V DC | 1.1-0.1 | 40W | Wire Leads | 0.40-0.17 | 47W | Wire Leads | Dimmable | 14 3/16" | 1 3/16" | 1" | 0° to 120° | 00000000 | 000000 |
10-54V DC | 1.4-0.1 | 50W | Wire Leads | 0.49-0.21 | 58W | Wire Leads | Dimmable | 14 3/16" | 1 3/16" | 1" | 0° to 120° | 00000000 | 00000 |
27-54V DC | 1.5-0.1 | 54W | Wire Leads | 0.54-0.23 | 65W | Wire Leads | Dimmable | 14 3/16" | 1 3/16" | 1" | 0° to 120° | 00000000 | 00000 |
27-54V DC | 2-0.1 | 75W | Wire Leads | 0.70-0.30 | 86W | Wire Leads | Dimmable | 16 5/8" | 1 3/16" | 1" | 0° to 120° | 00000000 | 00000 |
Output | Input | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Wattage | Wire Connection Type | Current, A | Max. Wattage | Wire Connection Type | Light Setting | Lg. | Wd. | Ht. | Temperature Range, °F | Each | |
120-277V AC Input Voltage | |||||||||||||
27-54V DC | 2-0.1 | 75W | Wire Leads | 0.73-0.31 | 87W | Wire Leads | Dimmable | 6 1/4" | 3" | 1 5/16" | 0° to 120° | 00000000 | 000000 |
Electronic Ballasts for Plug-In Compact Fluorescent Light Bulbs

In addition to being more energy-efficient than magnetic ballasts, these electronic ballasts are lighter and quieter. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Instant-start ballasts turn on immediately. They are the most energy-efficient, but shorten the bulb's life.
Programmed-start ballasts provide the longest bulb life, but take longer than instant-start ballasts to turn on. They are often used with motion-sensing light controls.
Ballasts that cannot be sold to Canada are restricted by local product labeling requirements.
No. of | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Bulb Base Type | For No. of Bulbs | For Bulb Wattage | Voltage | Wire Connection Type | Wire Leads | Terminals | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Cannot Be Sold To | Each | |
Instant Start | |||||||||||||||
For Twin Tube Bulbs | |||||||||||||||
Four Pin | 1, 2 | 40W | 120V/277V | Wire Leads | 5 | __ | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | 0° | UL Listed | __ | 0000000 | 000000 |
Four Pin | 2, 3 | 40W | 120V/277V | Wire Leads | 6 | __ | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | 0° | UL Listed | __ | 0000000 | 00000 |
Programmed Start | |||||||||||||||
For Twin Tube Bulbs | |||||||||||||||
Four Pin | 1 | 24W, 36W, 40W | 120V/277V | Spring-Clamp Terminals | __ | 9 | Not Dimmable | 14 1/4" | 1 1/4" | 1 1/8" | 0° | UL Listed | __ | 0000000 | 00000 |
Four Pin | 1, 2 | 24W, 36W, 40W | 120V/277V | Spring-Clamp Terminals | __ | 9 | Not Dimmable | 14 1/4" | 1 1/4" | 1" | 0° | UL Listed | Canada | 0000000 | 00000 |
Four Pin | 1, 2 | 36W, 50W, 55W | 120V/277V | Spring-Clamp Terminals | __ | 9 | Not Dimmable | 14 1/4" | 1 1/4" | 1 1/8" | -20° | UL Listed | __ | 0000000 | 00000 |
For Quad Tube and Triple U-Shaped Bulbs | |||||||||||||||
Four-Pin Wedge | 1, 2 | 13W | 120V/277V | Wire Leads | 9 | __ | Not Dimmable | 4 5/8" | 2 1/2" | 1" | 0° | UL Listed | __ | 0000000 | 00000 |
Four-Pin Wedge | 1, 2 | 18W | 120V/277V | Wire Leads | 9 | __ | Not Dimmable | 4 5/8" | 2 1/2" | 1" | 0° | UL Listed | Canada | 0000000 | 00000 |
Four-Pin Wedge | 1, 2 | 26W | 120V/277V | Wire Leads | 9 | __ | Not Dimmable | 4 5/8" | 2 1/2" | 1" | 0° | UL Listed | __ | 0000000 | 00000 |
Four-Pin Wedge | 2 | 26W, 32W, 42W | 120V/277V | Wire Leads | 9 | __ | Not Dimmable | 4 5/8" | 3" | 1 3/8" | 0° | UL Listed | __ | 0000000 | 00000 |
Magnetic Ballasts for Plug-In Compact Fluorescent Light Bulbs

These ballasts are often found in older installations. All are preheat ballasts so they take several seconds to start.
For Bulb | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Shape | Base Type | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Each | |
Preheat Start | |||||||||||||
Twin Tube | Two-Pin Wedge | 1 | 5W, 7W, 9W | 120V | 2 | Not Dimmable | 2 3/8" | 1 3/8" | 1 3/8" | 0° | UL Listed | 0000000 | 000000 |
Quad Tube | Two-Pin Wedge | 1 | 26W | 120V | 3 | Not Dimmable | 6 1/2" | 2 3/8" | 1 1/2" | 50° | UL Listed | 0000000 | 00000 |
Ballasts for Metal Halide Light Bulbs

Probe-start ballasts are often found in older installations.
Pulse-start ballasts turn on faster than probe start. Some include a starter, which increases bulb life.
For Bulb Wattage | Voltage | Ballast ANSI Number | Number of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Mounting Hardware Included | Includes | Each | |
Magnetic Ballasts | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Probe Start | |||||||||||
250W | 120V/208V/240V/277V/480V | M58 | 8 | Not Dimmable | 4 3/4" | 4 1/4" | 3 1/8" | Yes | Capacitor | 00000000 | 0000000 |
400W | 120V/208V/240V/277V/480V | M59 | 8 | Not Dimmable | 4 3/4" | 4 1/4" | 4" | Yes | Capacitor | 00000000 | 000000 |
1,000W | 120V/208V/240V/277V/480V | M47 | 8 | Not Dimmable | 6" | 4 1/4" | 5 5/8" | Yes | Capacitor | 00000000 | 000000 |
Pulse Start | |||||||||||
100W | 120V/208V/240V/277V | M90 | 6 | Not Dimmable | 4" | 2 7/8" | 3" | Yes | Capacitor, Starter | 00000000 | 000000 |
175W | 120V/208V/240V/277V/480V | M57 | 7 | Not Dimmable | 4" | 2 7/8" | 3 7/8" | Yes | Capacitor | 00000000 | 000000 |
320W | 120V/208V/240V/277V | M132, M154, M170 | 10 | Not Dimmable | 4 3/4" | 4 1/4" | 3 3/4" | Yes | Capacitor, Starter | 00000000 | 000000 |
350W | 120V/208V/240V/277V | M131, M171 | 10 | Not Dimmable | 4 3/4" | 4 1/4" | 3 3/4" | Yes | Capacitor, Starter | 00000000 | 000000 |
400W | 120V/208V/240V/277V/480V | M135, M155 | 7 | Not Dimmable | 4 3/4" | 4 1/4" | 4 1/8" | Yes | Capacitor, Starter | 00000000 | 000000 |
Starters for Metal Halide Light Bulbs


Pair these starters with pulse-start ballasts for metal halide bulbs.
Starters for High-Pressure Sodium Light Bulbs


Pair these starters with ballasts for high-pressure sodium bulbs.
For Ballast | ||||||||
---|---|---|---|---|---|---|---|---|
For Bulb Wattage | Type | ANSI Number | Dia. | Lg. | Max. Distance from Ballast, ft. | Specifications Met | Each | |
35W-150W | Magnetic | S54, S55, S62, S68, S76 | 1 1/4" | 2" | 2 | CSA Certified, UL Recognized Component | 00000000 | 000000 |
150W-400W | Magnetic | S50, S51, S56, S66, S67 | 1 1/4" | 2 1/2" | 2 | CSA Certified, UL Recognized Component | 00000000 | 00000 |
1,000W | Magnetic | S52 | 2 1/4" | 4 3/4" | 15 | CSA Certified, UL Recognized Component | 00000000 | 000000 |
Ballasts for High-Pressure Sodium Light Bulbs

For Bulb Wattage | Voltage | Ballast ANSI No. | Number of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Mounting Hardware Included | Includes | Each | |
Magnetic Ballasts | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
70W | 120V/208V/240V/277V | S62 | 6 | Not Dimmable | 4" | 2 7/8" | 2 7/8" | Yes | Capacitor, Starter | 00000000 | 0000000 |
100W | 120V/208V/240V/277V | S54 | 6 | Not Dimmable | 4" | 2 7/8" | 3 1/2" | Yes | Capacitor, Starter | 00000000 | 000000 |
150W | 120V/208V/240V/277V | S55 | 7 | Not Dimmable | 4" | 2 7/8" | 4" | Yes | Capacitor, Starter | 00000000 | 000000 |
250W | 120V/208V/240V/277V/480V | S50 | 11 | Not Dimmable | 4 3/4" | 4 1/4" | 3 5/8" | Yes | Capacitor, Starter | 00000000 | 000000 |
400W | 120V/208V/240V/277V/480V | S51 | 11 | Not Dimmable | 4 3/4" | 4 1/4" | 4 3/8" | Yes | Capacitor, Starter | 00000000 | 000000 |
1,000W | 120V/208V/240V/277V/480V | S52 | 11 | Not Dimmable | 6" | 4 1/4" | 6" | Yes | Capacitor, Starter | 00000000 | 000000 |