About Torque Tools
More
Opening-and-Closing Torque Testers for Caps and Knobs

Measure the twisting force needed to tighten or loosen caps and knobs with these torque testers. Four adjustable gripping posts clamp round and irregularly-shaped containers. Twist the top by hand to measure force or use it to calibrate your capping machine, so it applies the right amount of force in a production line. These testers have overload protection, which prevents damage to the measuring system if you accidentally exceed the torque range.
View torque measurements, change operating modes, and switch units of measurement on the LCD screen. Store data on the SD card, transfer it to your devices via Bluetooth or USB, or print using the DB9 cable. The I/O cable connects to controllers to operate other devices dependent on torque force readings.
Testers with a calibration certificate with test data traceable to NIST meet standards for accuracy.
Accuracy | Clamp | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque Range | Graduations | Torque-Measuring Direction | Clockwise | Counterclockwise | Ht. | Wd. | Dp. | Ht. | Opening Range | Voltage | Plug Type | Cord Lg., ft. | Each | |
Testers | ||||||||||||||
lbf-in., gf-m, Nm | ||||||||||||||
0.01 to 17 lbf-in. 0.1 to 200 gf-m 0.001 to 2 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 000000000 |
0.01 to 44 lbf-in. 0.1 to 500 gf-m 0.001 to 5 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
0.1 to 100 lbf-in. 0.1 to 1,000 gf-m 0.1 to 10 Nm | 0.1 lbf-in. 1 gf-m 0.01 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
Testers with Calibration Certificate with Test Data Traceable to NIST | ||||||||||||||
lbf-in., gf-m, Nm | ||||||||||||||
0.01 to 17 lbf-in. 0.1 to 200 gf-m 0.001 to 2 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
0.01 to 44 lbf-in. 0.1 to 500 gf-m 0.001 to 5 Nm | 0.01 lbf-in. 0.1 gf-m 0.001 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |
0.1 to 100 lbf-in. 0.1 to 1,000 gf-m 0.1 to 10 Nm | 0.1 lbf-in. 1 gf-m 0.01 Nm | Clockwise and Counterclockwise | ±0.5% | ±0.5% | 6" | 9 1/4" | 13 1/2" | 1 1/2" | 0.813" to 7" | 120V AC | Two Prong | 5 | 0000000 | 00000000 |