Maximum Flow Rate Maximum Flow Rate |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Outlet Coupling Type Outlet Coupling Type |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Outlet Type Outlet Type |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Air Preparation
More
About Air Compressors
More
Compressed Air Regulating Manifolds

±1.6% Accuracy (4 Station Shown)

±3.5% Accuracy (4 Station Shown)
Use a single air supply to meet the pressure requirements of multiple applications—connect one of these manifolds to your air line, and then set a different output pressure for each station. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Pipe Size | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Stations | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Pressure Regulating Range, psi | Each | |
Aluminum Housing—NPT Female Inlet and Outlet | |||||||||||
±1.6% Accuracy | |||||||||||
2 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 3 1/4" | 4 7/8" | 140° | 4.4-176 | 0000000 | 0000000 |
2 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 6 1/4" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
4 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 6 3/8" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
4 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 12 3/8" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
6 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 9 5/8" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
6 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 18 5/8" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
8 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 12 3/4" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
8 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 24 3/4" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
±3.5% Accuracy | |||||||||||
2 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 2 1/4" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
3 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 3" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
4 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 3 3/4" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
Compressed Air Regulating Manifolds for Air-Powered Tools

Run up to four air-powered tools from a single air supply. Two outlets deliver air at the same pressure as the air supply, and two outlets share a regulator so you can turn the knob to adjust the pressure within the range. The pressure gauge indicates air pressure at the regulated outlets.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube ID | Outlet Coupling Size (No. of Outlets) | Outlet Coupling Type | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Lg. | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | |
Zinc Housing | |||||||||||||
Plug-In Male Inlet × Push-to-Connect Female Outlet | |||||||||||||
3/8" | 1/4 (2 Unregulated, 2 Regulated) | ARO Quick-Disconnect, Industrial Quick-Disconnect | 20 scfm @ 100 psi | 200 | Yes | 12 1/2" | 7" | 4" | 120° | ±3% | 0-150 | 0000000 | 000000 |