About Sleeving
More
Interference-Shielding Expandable Sleeving
Use this braided copper sleeving to protect wire and cable from signal distortion caused by nearby equipment and devices. It’s expandable, so it stretches to fit over items for easy installation, then tightens around its contents for a secure fit. The braided construction permits heat and moisture to dissipate. Cut with sheet metal snips.
Per Ft. | |||||||
---|---|---|---|---|---|---|---|
ID | Expanded ID | Wall Thick. | Temperature Range | Lengths, ft. | 1-99 | 100-Up | |
Tin-Coated Copper | |||||||
1/4" | 5/16" | 1/32" | Not Rated | 0000000 | 00000 | 00000 | |
3/8" | 7/16" | 1/32" | Not Rated | 0000000 | 0000 | 0000 | |
1/2" | 9/16" | 1/32" | Not Rated | 0000000 | 0000 | 0000 | |
25/32" | 7/8" | 1/32" | Not Rated | 0000000 | 0000 | 0000 | |
1" | 1 1/8" | 1/16" | Not Rated | 0000000 | 00000 | 0000 | |
1 1/8" | 1 1/4" | 1/16" | Not Rated | 0000000 | 00000 | 00000 | |
1 1/4" | 1 3/8" | 1/16" | Not Rated | 0000000 | 00000 | 00000 | |
1 1/2" | 1 5/8" | 1/16" | Not Rated | 0000000 | 00000 | 00000 |
Harsh Environment High-Current Distribution Bars
Protect connections against corrosion. These bars are tin-plated copper and have stainless steel terminals. Also known as bus bars, they serve as connection points between wires with ring or spade terminals. The underside is sealed, so the bars can be safely mounted to conductive surfaces.
Covers protect the top of the bar and prevent accidental contact with live circuits.
For technical drawings and 3-D models, click on a part number.
Distribution Bars | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Terminals | Mounting Holes | Covers | |||||||||||
300V AC | 48V DC | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Stud Terminals | ||||||||||||||
1-Circuit Bars | ||||||||||||||
100A | 100A | 4 | No. 10 | 4 3/16" | 7/8" | 1 1/8" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 00000 |
130A | 150A | 4 | 1/4" | 5 7/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
250A | 250A | 4 | 5/16" | 5 7/8" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
250A | 250A | 6 | 5/16" | 7 3/4" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 000000 | 00000 | 0000000 | 00000 |
Distribution Bars | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Terminals | Mounting Holes | Covers | |||||||||||
300V AC | 48V DC | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Screw Terminals | ||||||||||||||
2-Circuit Blocks | ||||||||||||||
100A | 100A | 5 | No. 8 | 3" | 1 13/16" | 9/16" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 000000 |
100A | 100A | 10 | No. 8 | 5 1/16" | 1 13/16" | 9/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
Distribution Bars | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Stud Terminals | Screw Terminals | Mounting Holes | Covers | ||||||||||||
300V AC | 48V DC | No. Per Circuit | Size | No. Per Circuit | Size | Lg. | Wd. | Ht. | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | Each | ||
Stud and Screw Terminals | ||||||||||||||||
1-Circuit Bars | ||||||||||||||||
100A | 100A | 2 | No. 10 | 5 | No. 8 | 4 3/16" | 7/8" | 1 1/8" | No | 0.21" | 2 | CE Marked | 0000000 | 000000 | 0000000 | 00000 |
130A | 150A | 2 | 1/4" | 10 | No. 8 | 5 7/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
130A | 150A | 2 | 1/4" | 20 | No. 8 | 9 1/8" | 1 1/4" | 1 1/2" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 0000 |
250A | 250A | 2 | 5/16" | 6 | No. 10 | 5 7/8" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 000000 | 00000 | 0000000 | 00000 |
250A | 250A | 2 | 5/16" | 12 | No. 10 | 7 3/4" | 1 1/2" | 1 11/16" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 0000000 | 00000 |
545A | 600A | 4 | 3/8" | 4 | No. 8 | 7" | 2" | 2" | No | 0.26" | 4 | CE Marked | 000000 | 000000 | 0000000 | 00000 |
545A | 600A | 8 | 3/8" | 4 | No. 8 | 11 3/8" | 2" | 2" | No | 0.39" | 4 | CE Marked | 000000 | 000000 | 000000 | 00 |
2-Circuit Bars | ||||||||||||||||
130A | 150A | 2 | 1/4" | 5 | No. 10 | 4 7/8" | 2 9/16" | 1 1/4" | No | 0.21" | 2 | CE Marked | 0000000 | 00000 | 000000 | 00 |
Modular Distribution Bars
Build your own distribution system for neutral and grounding applications by adding terminal blocks to these bars. Slide blocks onto the bar, also known as a bus bar, and then attach mounting brackets to the bar. All wires make contact with the bar, distributing the current among the terminal blocks.
Terminal blocks have screw-clamp terminals that secure the wire as well as the block to the bar. Blocks are UL recognized for grounding applications.
For technical drawings and 3-D models, click on a part number.
Terminal Blocks | Blank Marker Cards | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits | For Wire Gauge | Wire Connection Type | Wd., mm | Lg., mm | Ht., mm | Specifications Met | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | ||
1 | 22-10 | Screw-Clamp Terminals | 7.5 | 30 | 23.3 | UL Recognized Component | 5 | 0000000 | 00000 | 100 | 0000000 | 00000 |
1 | 10-4 | Screw-Clamp Terminals | 9.8 | 36 | 23.3 | UL Recognized Component | 5 | 0000000 | 0000 | 100 | 0000000 | 0000 |
1 | 8-2 | Screw-Clamp Terminals | 14.5 | 45 | 27.3 | UL Recognized Component | 5 | 0000000 | 0000 | 100 | 0000000 | 0000 |
Wraparound Bench Vise Jaw Liners
Fold the pliable tabs over vise jaws to protect workpieces from marring.
Copper liners resist weld spatter.