Measure small changes in air pressure with these gauges. They are commonly used to indicate clogged filters and to monitor fans and blowers.
Service these gauges without removing them using air filter kits. Kits include two vent valves for releasing air.
Surface mounting brackets allow gauges to be quickly installed on any flat surface. L mounting brackets can be carried to wherever you need to take a pressure reading. They can stand alone or be hung. Wraparound mounting brackets make it easy to service tubing, and don’t require cutting a hole in the wall.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, in. of H₂O | Graduation Marks, in. of H₂O | Numeric Increments, in. of H₂O |
0 to 0.25 | 0.005 | 0.05 |
0 to 0.5 | 0.01 | 0.1 |
0 to 1 | 0.02 | 0.2 |
0 to 2 | 0.05 | 0.25 |
0 to 3 | 0.1 | 1 |
0 to 4 | 0.1 | 1 |
0 to 5 | 0.1 | 1 |
0 to 6 | 0.2 | 1 |
0 to 8 | 0.2 | 2 |
0 to 10 | 0.2 | 2 |
0 to 15 | 0.5 | 5 |
0 to 20 | 0.5 | 5 |
0 to 25 | 0.5 | 5 |
0 to 30 | 1 | 10 |
0 to 40 | 1 | 5 |
0 to 50 | 1 | 10 |
0 to 80 | 2 | 20 |
0 to 100 | 2 | 20 |
0 to 150 | 5 | 50 |
Dial Diameter | Pipe Size | Max. Pressure, psi | Environment Temp. Range, °F | Process Temp. Range, °F | Features | Includes | Each | |
NPT Female | ||||||||
---|---|---|---|---|---|---|---|---|
4" | 1/8 | 15 | 20° to 140° | 20° to 140° | Two Inlets and Two Outlets | Plugs for Unused Ports | 0000000 | 000000 |
NPT Female with NIST Certificate | ||||||||
4" | 1/8 | 15 | 20° to 140° | 20° to 140° | Two Inlets and Two Outlets | Plugs for Unused Ports | 0000000 | 000000 |
Includes | Each | |
9-ft. Lg. × 3/16" ID Tubing Carrying Case Mounting Bracket Two Pipe-to-Tube Adapters | 0000000 | 000000 |
Includes | Each | |
Mounting Bracket Mounting Fasteners Two 5-ft. Lg. Aluminum Tubing Two Pressure Tips Two Vent Valves | 0000000 | 000000 |
Includes | Each | |
7-ft. Lg. PVC Tubing Two Pressure Tips | 0000000 | 00000 |
A band of green, yellow, and red provides a clear indication of changes in differential pressure. Gauges are commonly used to indicate clogged filters.
For technical drawings and 3-D models, click on a part number.
Pressure Range, psi | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Green Band | Yellow Band | Red Band | Max. Pressure, psi | Environment Temp. Range, °F | Process Temp. Range, °F | Ht. | Wd. | Dp. | Case Color | Each | |
NPT Female | ||||||||||||
1/4 | 0-2 | 2-2.5 | 2.5-3.5 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 000000 |
1/4 | 0-3 | 3-4.5 | 4.5-5 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 00000 |
1/4 | 0-6 | 6-9 | 9-12 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 00000 |
1/4 | 0-7.5 | 7.5-12 | 12-15 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 00000 |
1/4 | 0-13 | 13-20 | 20-30 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 00000 |
1/4 | 0-19.5 | 19.5-29.5 | 29.5-43 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 00000 |
Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | bar | Resolution, psi | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kPa | in. of H₂O | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
Also known as manometers, these gauges come with indicating liquid that moves up and down two columns—the difference in height between them is your pressure. They are commonly used to indicate clogged filters.
Magnet-mount gauges can be moved for use in multiple locations. Gauges with barbed tube connection have a flexible body that rolls up for storage or transport.
Environment Temp. Range | Process Temp. Range | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, in. of H₂O | Scale Range, in. of H₂O | Numeric Increments, in. of H₂O | Graduation Marks, in. of H₂O | Max. Pressure, psi | Ht. | Min., °F | Max., °F | Min., °F | Max., °F | Gender | Mount Type | Fasteners Included | Hole Dia. | Number of Holes | Each | |
With 1/4 NPT Female Threaded Pipe Connection | ||||||||||||||||
0-10 | 5-0-5 | 1 | 0.1 | 250 | 14" | 35° | 150° | 35° | 250° | Female | Screw On | No | 3/16" | 4 | 0000000 | 0000000 |
0-15 | 7-0-7 | 1 | 0.1 | 250 | 18" | 35° | 150° | 35° | 250° | Female | Screw On | No | 3/16" | 4 | 0000000 | 000000 |
Pressure Range, in. of H₂O | Scale Range, in. of H₂O | Numeric Increments, in. of H₂O | Graduation Marks, in. of H₂O | Max. Pressure | Ht. | Max. Process Temp., °F | Gender | Mount Type | Each | |
With Barbed Tube Connection for 3/16" Tube ID | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-8 | 4-0-4 | 1 | 0.1 | Not Rated | 17" | 130° | Male | Magnet | 0000000 | 000000 |
0-12 | 6-0-6 | 1 | 0.1 | Not Rated | 21" | 130° | Male | Magnet | 0000000 | 000000 |
0-16 | 8-0-8 | 1 | 0.1 | Not Rated | 25" | 130° | Male | Magnet | 0000000 | 000000 |
0-24 | 12-0-12 | 1 | 0.1 | Not Rated | 33" | 130° | Male | Magnet | 0000000 | 000000 |
0-30 | 15-0-15 | 1 | 0.1 | Not Rated | 39" | 130° | Male | Magnet | 0000000 | 000000 |
0-36 | 18-0-18 | 1 | 0.1 | Not Rated | 45" | 130° | Male | Magnet | 0000000 | 000000 |
0-48 | 24-0-24 | 1 | 0.1 | Not Rated | 57" | 130° | Male | Magnet | 0000000 | 000000 |
0-60 | 30-0-30 | 1 | 0.1 | Not Rated | 69" | 130° | Male | Magnet | 0000000 | 000000 |
0-72 | 36-0-36 | 1 | 0.1 | Not Rated | 81" | 130° | Male | Magnet | 0000000 | 000000 |
Pressure Range, in. of H₂O | Scale Range, in. of H₂O | Numeric Increments, in. of H₂O | Graduation Marks, in. of H₂O | Max. Pressure, psi | Ht. | Gender | Mount Type | Each | |
With Compression Tube Connection for 1/4" Tube OD | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-8 | 4-0-4 | 1 | 0.1 | 100 | 20" | Female | Magnet | 0000000 | 0000000 |
0-12 | 6-0-6 | 1 | 0.1 | 100 | 25" | Female | Magnet | 0000000 | 000000 |
0-16 | 8-0-8 | 1 | 0.1 | 100 | 30" | Female | Magnet | 0000000 | 000000 |
0-20 | 10-0-10 | 1 | 0.1 | 100 | 34" | Female | Magnet | 0000000 | 000000 |
0-24 | 12-0-12 | 1 | 0.1 | 100 | 39" | Female | Magnet | 0000000 | 000000 |
0-36 | 18-0-18 | 1 | 0.1 | 100 | 58" | Female | Magnet | 0000000 | 000000 |
Refill U-tube gauges.
Concentrated solutions should be diluted with distilled water prior to use.
Easier to read than U-tube gauges, these use an inclined scale to measure pressure or velocity in air applications. Gauges are also known as manometers.
Indicating Liquid | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, in. of H₂O | Max. Pressure, psi | Max. Process Temp. Range, °F | Ht. | Color | Specific Gravity | Mount Type | Mounting Fasteners Included | Includes | Each | |
With Barbed Tube Connection for 3/16" Tube ID | ||||||||||
0-3 | 10 | 140° | 6" | Red | 0.826 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
0-7 | 10 | 140° | 6" | Blue | 1.91 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
These gauges are able to withstand line pressures up to 3,000 psi. They are commonly used to measure pressure differences in pumps and filters.
Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
2 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
0 to 15 | 1 | 3 |
0 to 20 | 1 | 5 |
0 to 25 | 1 | 5 |
0 to 30 | 2 | 10 |
0 to 40 | 2.5 | 10 |
0 to 50 | 2.5 | 10 |
0 to 100 | 5 | 20 |
4 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
0 to 15 | 0.5 | 3 |
0 to 20 | 1 | 5 |
0 to 25 | 1 | 5 |
0 to 30 | 1 | 10 |
0 to 40 | 2 | 10 |
0 to 50 | 2.5 | 10 |
0 to 100 | 5 | 20 |
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
2 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
0 to 15 | 1 | 3 |
0 to 20 | 1 | 5 |
0 to 25 | 1 | 5 |
0 to 30 | 2 | 10 |
0 to 40 | 2.5 | 10 |
0 to 50 | 2.5 | 10 |
0 to 100 | 5 | 20 |
4 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
0 to 15 | 0.5 | 3 |
0 to 20 | 1 | 5 |
0 to 25 | 1 | 5 |
0 to 30 | 1 | 10 |
0 to 40 | 2 | 10 |
0 to 50 | 2.5 | 10 |
0 to 100 | 5 | 20 |
Popular for use with natural gas, these gauges measure pressure differences in pipelines and filters with a maximum pressure of 1,500 psi.
Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 2 | 0.1 | 0.5 |
0 to 5 | 0.25 | 1 |
0 to 10 | 0.5 | 2 |
0 to 15 | 1 | 3 |
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 2 | 0.1 | 0.5 |
0 to 5 | 0.25 | 1 |
0 to 10 | 0.5 | 2 |
0 to 15 | 1 | 3 |
Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
For technical drawings and 3-D models, click on a part number.
Available Pressure and Vacuum Ranges | |||
---|---|---|---|
Pressure Range, in. of H₂O | Vacuum Range, in. of H₂O | Graduation Marks, in. of H₂O | Numeric Increments, in. of H₂O |
0 to 0.2" | -0.05" to 0 | 0.01 | 0.05 |
0 to 0.25" | -0.25" to 0 | 0.01 | 0.05 |
0 to 0.5" | -0.5" to 0 | 0.02 | 0.1 |
0 to 1" | -1" to 0 | 0.05 | 0.25 |
0 to 5" | -5" to 0 | 0.2 | 1 |
0 to 10" | -10" to 0 | 0.5 | 5 |
0 to 15" | -15" to 0 | 1 | 5 |
Dial Diameter | Pipe Size | Max. Pressure, psi | Environment Temp. Range, °F | Process Temp. Range, °F | Features | Includes | Each | |
NPT Female | ||||||||
---|---|---|---|---|---|---|---|---|
4" | 1/8 | 15 | 20° to 140° | 20° to 140° | Two Inlets and Two Outlets | Plugs for Unused Ports | 00000000 | 000000 |
NPT Female with NIST Certificate | ||||||||
4" | 1/8 | 15 | 20° to 140° | 20° to 140° | Two Inlets and Two Outlets | Plugs for Unused Ports | 0000000 | 000000 |
Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
Pressure Range | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | kPa | in. of H₂O | mbar | Vacuum Range, in. of Hg | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Batteries Included | Features | Each | |
Barbed Tube Connection | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 0000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Use these sensors with differential pressure gauges and switches to measure the static pressure drop across air filters, cooling coils, and blowers in air-handling equipment. Install them in duct through a hole and connect to your gauge with tubing.
Sensors with pressure tubes give more accurate measurements in applications with high air flow. Style D is held in place with a magnet so you can move it for use in multiple locations.
Style | For Tube ID | For Tube OD | Insertion Dp. | Tube Connection Type | Gender | Mount Type | Material | Features | Each | |
A | 1/8"-3/16" | __ | __ | Barbed | Male | Screw On | Brass | __ | 0000000 | 00000 |
B | __ | 1/4" | __ | Compression | Female | Screw On | Brass | __ | 0000000 | 0000 |
C | 1/8"-3/16" | __ | 4" | Barbed | Male | Screw On | Brass | Pressure Tubes | 0000000 | 00000 |
D | 3/16" | __ | 3" | Barbed | Male | Magnetic | Brass | Pressure Tubes | 0000000 | 00000 |
E | __ | 1/4" | 4" | Compression | Female | Screw On | Brass | Pressure Tubes | 0000000 | 00000 |
Also known as pitot tubes, these can be used with manometers to measure air flow rate. Sensors have inch graduation marks so you can monitor your insertion depth.
For Tube ID | Insertion Dp. | OD | For Min. Duct Dia. | Tube Connection Type | Gender | Material | Each | |
1/4" | 8 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |
1/4" | 12 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 00000 |
1/4" | 18 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |
1/4" | 24 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |