Airflow Airflow |
---|
|
Mobility Mobility |
---|
|
Fan Head Movement Fan Head Movement |
---|
|
Motor Enclosure Type Motor Enclosure Type |
---|
|
Volume Volume |
---|
|
Specifications Met Specifications Met |
---|
|
Environmental Rating Environmental Rating |
---|
NEC Hazardous Location Temperature Classification NEC Hazardous LocationTemperature Classification |
---|
|
Environment Environment |
---|
|
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations.
Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
Add an optional misting kit to make fans produce a fine mist when connected to a garden hose. There are five misting nozzles, each with an inline filter to prevent clogging. These kits are not recommended for indoor use.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | Each | ||
Open Dripproof Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
30" | 8,200 | 67 dBA @ 15 ft. | 1,090 | 2 | 1/4 | 3.5 | 34" | 33" | 15" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 0000000 | 00000000 | 000000 |
36" | 10,900 | 72 dB @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 40" | 39" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 000000 | 00000000 | 00000 |
42" | 13,600 | 75 dB @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 46" | 45" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 000000 | 00000000 | 00000 |
Totally Enclosed Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
36" | 10,900 | 72 dBA @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 40" | 39" | 21" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
42" | 13,600 | 75 dBA @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 46" | 45" | 21" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
48" | 19,100 | 78 dBA @ 15 ft. | 850 | 1 | 1 | 9.1 | 52" | 51" | 25" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
For Blade Dia. | Each | |
For Fans with Open Dripproof Motor Enclosure | ||
---|---|---|
36", 42" | 00000000 | 00000 |
Tilt fans to direct air where it's needed. These direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations.
Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
30" and 36" blade diameter fans can also mount to the wall and ceiling.
Add an optional misting kit to make fans produce a fine mist when connected to a garden hose. There are five misting nozzles, each with an inline filter to prevent clogging. These kits are not recommended for indoor use.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | Each | ||
Open Dripproof Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
42" | 13,600 | 75 dB @ 15 ft. | 825 | 2 | 1/2 | 6.0 | 54" | 51" | 27" | 10 | Steel | Steel | Steel | C-UL Listed, UL Listed | 000000000 | 000000000 | 00000000 | 000000 |
Totally Enclosed Motor Enclosure | ||||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||||
30" | 5,600 | 76 dB @ 15 ft. | 1,110 | 3 | 1/4 | 2.9 | 36" | 35" | 14" | 10 | Steel | Steel | Steel | UL Listed | 00000000 | 000000 | 000000000 | 00000 |
36" | 11,200 | 78 dB @ 15 ft. | 830 | 2 | 1/2 | 4.6 | 40" | 39" | 15" | 10 | Steel | Steel | Steel | UL Listed | 00000000 | 000000 | 000000000 | 00000 |
42" | 13,600 | 75 dB @ 15 ft. | 825 | 1 | 1/2 | 6.0 | 54" | 51" | 27" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 000000 | 00000000 | 00000 |
48" | 19,100 | 78 dB @ 15 ft. | 850 | 1 | 1 | 9.1 | 60" | 58" | 26" | 10 | Steel | Aluminum | Steel | C-UL Listed, UL Listed | 00000000 | 00000000 | 00000000 | 00000 |
For Blade Dia. | Each | |
For Fans with Open Dripproof Motor Enclosure | ||
---|---|---|
42" | 00000000 | 00000 |
With an aluminum housing, these fans stand up to corrosion better than the economy fans. They are direct-drive fans, which have fewer moving parts than belt-drive fans for less maintenance. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Blade Material | Guard Material | Specifications Met | Each | |
Totally Enclosed Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Three Prong Plug | ||||||||||||||||
30" | 9,100 | 65 dB @ 15 ft. | 825 | 1 | 1/2 | 7.0 | 32" | 34" | 15" | 10 | Aluminum | Aluminum | Powder-Coated Steel | C-UL Listed, UL Listed | 0000000 | 0000000 |
36" | 11,800 | 68 dB @ 15 ft. | 825 | 1 | 1/2 | 7.0 | 41" | 40" | 17" | 10 | Aluminum | Steel | Powder-Coated Steel | C-UL Listed, UL Listed | 0000000 | 000000 |
Often used to cool warehouse aisles and production lines, these fans generate a stream of air that travels farther than air from conventional fans. All have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Fan with plug connection and wheels is mobile.
Fan with hardwire connection and wheels can be rolled into place before it is hardwired. It does not allow for movement once the unit is in use.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Housing Material | Blade Material | Guard Material | Each | |
120V AC, Single Phase—Three-Prong Plug | |||||||||||||||
22" | 5,500 | 82 dB @ 15 ft. | 1,725 | 1 | 1/2 | 6.0 | 55" | 32" | 35" | Non-Oscillating | Polypropylene Plastic | Aluminum | Steel | 0000000 | 000000000 |
208-230/460V AC, Three Phase—Hardwire | |||||||||||||||
30" | 12,000 | 94 dB @ 15 ft. | 1,800 | 1 | 1 | 3.6/1.8 | 70" | 32" | 35" | Non-Oscillating | Steel | Aluminum | Steel | 0000000 | 00000000 |
Fans with wheels can be rolled into place before they are hardwired. They do not allow for movement once the unit is in use.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Drive Type | Housing Material | Blade Material | Guard Material | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
24" | 7,800 | 78 dB @ 15 ft. | 1,750 | 1 | 1 | 14.0/6.9 | 45" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 000000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
36" | 20,000 | 86 dB @ 15 ft. | 1,750 | 1 | 3 | 8.2/4.1 | 51" | 42" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Fan Head Movement | Drive Type | Housing Material | Blade Material | Guard Material | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
18" | 4,000 | 72 dB @ 15 ft. | 1,750 | 1 | 1/3 | 6.0/3.0 | 38" | 24" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 000000000 |
24" | 7,800 | 78 dB @ 15 ft. | 1,750 | 1 | 1 | 14.0/6.9 | 41" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 00000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
24" | 7,800 | 78 dB @ 15 ft. | 1,750 | 1 | 1 | 3.0/1.5 | 41" | 30" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |
36" | 20,000 | 86 dB @ 15 ft. | 1,750 | 1 | 3 | 8.2/4.1 | 47" | 42" | 32" | Non-Oscillating | Direct | Steel | Aluminum | Steel | 0000000 | 00000000 |