Install these low-profile valves in tight spots.
Short lever handles, T-handles, and screwdriver-operated handles resist accidental movement when snagged or bumped.
Pipe Size | Max. Pressure | Temperature Range, °F | End-to-End Lg. | Each | |
NPT Female × NPT Female | |||||
---|---|---|---|---|---|
1/8 | 500 psi @ 210° F | -20° to 550° | 1 13/16" | 0000000 | 000000 |
1/4 | 500 psi @ 210° F | -20° to 550° | 2" | 0000000 | 00000 |
NPT Male × NPT Female | |||||
1/8 | 500 psi @ 210° F | -20° to 550° | 1 13/16" | 0000000 | 00000 |
1/4 | 500 psi @ 210° F | -20° to 550° | 2" | 0000000 | 00000 |
NPT Male × NPT Male | |||||
1/8 | 500 psi @ 210° F | -20° to 550° | 1 13/16" | 0000000 | 00000 |
1/4 | 500 psi @ 210° F | -20° to 550° | 2" | 0000000 | 00000 |
NPT Male × Drain | |||||
1/8 | 500 psi @ 210° F | -20° to 550° | 1 13/16" | 0000000 | 00000 |
1/4 | 500 psi @ 210° F | -20° to 550° | 2" | 0000000 | 00000 |
These valves have barbs that grip onto tubing, providing a secure hold.
Nickel-plated brass valves are more corrosion resistant than plain brass valves.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Pipe Size | For Tube ID | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | End-to-End Lg. | Each | |
Brass Body | |||||||
---|---|---|---|---|---|---|---|
NPTF Male × Barbed | |||||||
1/8 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 9/16" | 0000000 | 000000 |
1/4 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 5/8" | 0000000 | 00000 |
3/8 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 11/16" | 0000000 | 00000 |
1/2 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 13/16" | 0000000 | 00000 |
Nickel-Plated Brass Body | |||||||
NPTF Male × Barbed | |||||||
1/8 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 9/16" | 0000000 | 00000 |
1/4 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 5/8" | 0000000 | 00000 |
3/8 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 11/16" | 0000000 | 00000 |
1/2 | 3/8" | 1.4 | 250 psi @ 180° F | 35° to 180° | 2 13/16" | 0000000 | 00000 |
Often used to control single-acting, spring-return air cylinders, these valves have a third threaded port to exhaust media. They operate on electricity to automatically start and stop flow.
Valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Normally closed valves exhaust media unless actuated; when actuated, they close the exhaust port and reverse the direction of flow to send media to equipment. Normally open valves send media to equipment unless actuated; when actuated, they open the exhaust port and reverse the direction of flow to exhaust media.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits for Flow-Control Valves | Replacement Solenoid Coils | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | No. of Ports | Each | Each | Each | |||
Brass Body with Wire Leads | |||||||||||||||
Normally Closed—24V AC | |||||||||||||||
1/4 | Female | NPT | 0.2 | 95 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 1 3/4" | 3 5/8" | 3 | 00000000 | 0000000 | 000000 | 00 | 0000000 | 000000 |
1/4 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/8" | 3 | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
3/8 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/8" | 3 | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
3/8 | Female | NPT | 7.3 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 2 5/8" | 5 5/16" | 3 | 00000000 | 000000 | 0000000 | 0000000 | 000000 | 00 |
1/2 | Female | NPT | 3.6 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 3 1/16" | 5 5/8" | 3 | 00000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
3/4 | Female | NPT | 7.3 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 3 3/8" | 6 1/2" | 3 | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
Normally Closed—120V AC | |||||||||||||||
1/4 | Female | NPT | 0.2 | 95 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 1 3/4" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
1/4 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/8" | 3 | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
3/8 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/8" | 3 | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
3/8 | Female | NPT | 2.1 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 2 5/8" | 5 5/16" | 3 | 00000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
1/2 | Female | NPT | 3.6 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 3 1/16" | 5 5/8" | 3 | 00000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
3/4 | Female | NPT | 7.3 | 180 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 3 3/8" | 6 1/2" | 3 | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
Normally Open—24V AC | |||||||||||||||
1/4 | Female | NPT | 0.2 | 95 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 1 3/4" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
3/8 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
Normally Open—120V AC | |||||||||||||||
1/4 | Female | NPT | 0.2 | 95 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 1 3/4" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
1/4 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
3/8 | Female | NPT | 0.8 | 200 psi @ 70° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 5/8" | 3 | 00000000 | 000000 | 000000 | 00 | 0000000 | 00000 |
Insert tubing into the fittings on these valves—no heat, solder, or flux required. They operate on electricity to automatically start and stop flow.
Valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Tube OD | Gender | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Quick-Disconnect Tab Wd. | Each | |
Polycarbonate Plastic Body with Quick-Disconnect Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—24V DC | ||||||||||
1/4" | Female | 0.31 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 000000 |
1/4" | Female | 0.37 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 00000 |
3/8" | Female | 1 | 5 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2 3/8" | 3" | 1/4" | 00000000 | 00000 |
Normally Closed—120V AC | ||||||||||
1/4" | Female | 0.31 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 00000 |
1/4" | Female | 0.37 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 00000 |
3/8" | Female | 1 | 5 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2 3/8" | 3" | 1/4" | 00000000 | 00000 |
Polysulfone Plastic Body with Quick-Disconnect Terminals | ||||||||||
Normally Closed—24V DC | ||||||||||
1/4" | Female | 0.23 | 120 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 00000 |
Normally Closed—120V AC | ||||||||||
1/4" | Female | 0.23 | 120 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 00000000 | 00000 |