About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans



Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | Each | |||
120V AC, Single Phase—Hardwire | ||||||||||||||||||
3 | 8" | 400 | 34 dBA @ 15 ft. | 1,550 | 1 | 1/40 | 13" | 13" | 6 5/8" | 15 | 104° F | Steel | Aluminum | __ | 0000000 | 0000000 | 000000 | 00 |
3 | 10" | 600 | 42 dBA @ 15 ft. | 1,550 | 1 | 1/40 | 13" | 13" | 6 5/8" | 14 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
3 | 16" | 2,100 | Not Rated | 1,660 | 3 | 1/8 | 19 1/8" | 19 1/8" | 10 1/8" | 21 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 20" | 2,925 | Not Rated | 1,140 | 2 | 1/4 | 23 1/8" | 23 1/8" | 10" | 35 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 24" | 4,800 | 56 dB @ 5 ft. | 850 | 1 | 1/2 | 30" | 30" | 15 1/2" | 45 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 0000000 | 0000000 |
4 | 30" | 7,300 | 61 dB @ 5 ft. | 825 | 1 | 1/2 | 36" | 36" | 13 3/4" | 75 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
4 | 36" | 8,600 | 65 dB @ 5 ft. | 825 | 1 | 1/2 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||
3 | 20" | 6,200 | 56 dBA @ 15 ft. | 1,750 | 1 | 3/4 | 28" | 28" | 15 5/8" | 60 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
208-230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
4 | 30" | 7,300 | 61 dB @ 5 ft. | 825 | 1 | 1/2 | 36" | 36" | 13 3/4" | 74 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
4 | 36" | 8,600 | 64 dB @ 5 ft. | 825 | 1 | 1/2 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
3 | 24" | 4,600 | 56 dB @ 5 ft. | 825 | 1 | 1/4 | 30" | 30" | 15 1/2" | 51 | 104° F | Steel | Aluminum | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 18" | 3,900 | 66 dB @ 5 ft. | 1,750 | 1 | 1/2 | 24" | 24" | 10" | 42 | 104° F | Steel | Steel | __ | 000000 | 000000 | 0000000 | 000000 |
5 | 24" | 6,800 | 72 dB @ 5 ft. | 1,750 | 1 | 1 | 30" | 30" | 12 1/4" | 78 | 104° F | Steel | Steel | __ | 000000 | 00000000 | 0000000 | 000000 |
5 | 30" | 14,400 | 80 dB @ 5 ft. | 1,750 | 1 | 3 | 36" | 36" | 14 1/4" | 148 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 36" | 20,300 | 83 dB @ 5 ft. | 1,750 | 1 | 5 | 42" | 42" | 15 3/4" | 225 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 42" | 26,600 | 80 dB @ 5 ft. | 1,150 | 1 | 5 | 48" | 48" | 20" | 295 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 48" | 37,100 | 82 dB @ 5 ft. | 1,150 | 1 | 7 1/2 | 54" | 54" | 22 1/2" | 470 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
Belt-Drive Wall-Mount Exhaust Fans
Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.


Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||
30" | 8,200 | 56 dB @ 5 ft. | 600 | 1 | 1/2 | 36" | 36" | 18 3/8" | Steel | Steel | 0000000 | 0000000 | 0000000 | 0000000 |
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 000000 | 0000000 | 000000 |
48" | 18,500 | 61 dB @ 5 ft. | 400 | 1 | 1 | 54" | 54" | 24 3/4" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
30" | 8,200 | 56 dB @ 5 ft. | 600 | 1 | 1/2 | 36" | 36" | 18 3/8" | Steel | Steel | 0000000 | 000000 | 0000000 | 000000 |
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
48" | 18,500 | 56 dB @ 5 ft. | 400 | 1 | 1 | 54" | 54" | 24 3/4" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
230/460V AC, Three Phase—Hardwire | ||||||||||||||
36" | 14,200 | 68 dB @ 5 ft. | 800 | 1 | 1 1/2 | 42" | 42" | 19 1/8" | Steel | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
48" | 26,800 | 72 dB @ 5 ft. | 600 | 1 | 3 | 54" | 54" | 24 7/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
54" | 37,600 | 70 dB @ 5 ft. | 525 | 1 | 5 | 60" | 60" | 23 1/2" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |