McMaster-Carr logo
    Filter by
    Blade Diameter
    Mounting Location
    Overall Height
    Power Source
    Drive Type
    Electrical Phase
    Overall Width
    Fan Head Movement
    Blade Material
    Frame Material
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Height
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    26 Products

    Economy Direct-Drive Mobile Floor Fans with Tilt Stand

    Tilt fans to direct air where it's needed. These direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Fans with Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Fans. Economy Direct-Drive Mobile Floor Fans with Tilt Stand.
    Image of Product. Front orientation. Wheels.

    Replacement Wheels

    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Fans
    Replacement Wheels
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Guard
    Material
    Certification
    Each
    Wheel
    Dia.
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan, Tilting Fan
    42"Steel13,600 ft³/min75 dBA @ 15 ft.82521/26.0 amp54"51"27"10DirectSteelSteelC-UL Listed, UL Listed
    00000000000000000010"00000000000000
     
    Replacements for Fans
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Economy Direct-Drive Mobile Floor Fans with Tilt Stand.
    Image of Product. Front orientation. Wheels.

    Replacement Wheels

    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and wet environments.
    Fans
    Replacement Wheels
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Guard
    Material
    Certification
    Each
    Wheel
    Dia.
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan, Tilting Fan
    42"Aluminum13,600 ft³/min75 dBA @ 15 ft.82511/26.0 amp54"51"27"10DirectSteelSteelC-UL Listed, UL Listed
    0000000000000000010"00000000000000
     

    Belt-Drive Wall-Mount Exhaust Fans

    Use these fans to draw stagnant and humid air out of a room or area. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    48"18,50061 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel000000000000000000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase—Hardwire
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    48"18,50056 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel000000000000000000000000000000
    Replacements for Exhaust Fans

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    548"37,10082 dB @ 5 ft.Direct1,15017 1/254"54"22 1/2"470104SteelSteel000000000000000000000000000000

    Panel Fans

    Image of ProductInUse. Shown Mounted with Chains (Not Included). Front orientation. Fans. Panel Fans.

    Shown Mounted with

    Chains (Not Included)

    Mount these fans to a wide range of surfaces, such as posts, columns, and ceilings. They’re direct-drive fans, so they have fewer moving parts than belt-drive fans and require less maintenance. To suspend them, use the mounting chain kit (sold separately). Use mounting brackets (sold separately) to mount them to posts and columns.
    Fans with Totally Enclosed Motor Enclosure
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Frame Material
    Enclosure
    Rating
    Each
    208V AC to 240V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic30,800 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp54"54"17 3/4"DirectGalvanized SteelIP65
    0000000000000000
     
    380V AC to 460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic29,600 ft³/minNot Rated60012 15/165.2 amp to 6.2 amp54"54"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    Accessories for Fans

    Belt-Drive Mobile Floor Fans with Tilt Stand

    Tilt fans to direct air where it's needed. These belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged.
    Fans with Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Fans. Belt-Drive Mobile Floor Fans with Tilt Stand.
    Image of Product. Front orientation. Wheels.

    Replacement Wheels

    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Fans
    Replacement Wheels
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Guard Material
    Certification
    Each
    Wheel
    Dia.
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan, Tilting Fan
    42"Aluminum14,445 ft³/min66 dBA @ 15 ft.50021/27.3 amp54"50"27"10BeltSteelPowder-Coated Steel0000000000000000010"00000000000000
    42"Aluminum16,900 ft³/min66 dBA @ 15 ft.50013/413.0 amp54"52"27"10BeltSteelSteelC-UL Listed, UL Listed
    00000000000000010"0000000000000
     

    Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.
    Image of Product. Front orientation. Exhaust Fan Collars. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    48"26,80072 dB @ 5 ft.Belt6001354"54"24 7/8"SteelSteel000000000000000000000000000000
    back to top