Electrical Phase Electrical Phase |
---|
|
Airflow Airflow |
---|
|
|
Voltage Voltage | Show |
---|
|
Voltage Voltage | Hide |
---|
Mounting Location Mounting Location |
---|
|
Drive Type Drive Type |
---|
|
Motor Enclosure Type Motor Enclosure Type |
---|
|
Power Source Power Source |
---|
|
Frame Material Frame Material |
---|
|
Blade Material Blade Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Volume Volume |
---|
|
|
Number of Speeds Number of Speeds |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Louver Blade Material Louver Blade Material |
---|
|
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
About Exhaust Fans
More
Belt-Drive Wall-Mount Exhaust Fans
Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.


Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
230/460V AC, Three Phase—Hardwire | ||||||||||||||
30" | 8,200 | 56 dB @ 5 ft. | 600 | 1 | 1/2 | 36" | 36" | 18 3/8" | Steel | Steel | 0000000 | 0000000 | 0000000 | 0000000 |
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
48" | 18,500 | 56 dB @ 5 ft. | 400 | 1 | 1 | 54" | 54" | 24 3/4" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
230/460V AC, Three Phase—Hardwire | ||||||||||||||
36" | 14,200 | 68 dB @ 5 ft. | 800 | 1 | 1 1/2 | 42" | 42" | 19 1/8" | Steel | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
48" | 26,800 | 72 dB @ 5 ft. | 600 | 1 | 3 | 54" | 54" | 24 7/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
54" | 37,600 | 70 dB @ 5 ft. | 525 | 1 | 5 | 60" | 60" | 23 1/2" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
60" | 50,000 | 79 dB @ 5 ft. | 500 | 1 | 7 1/2 | 66" | 66" | 23 1/2" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Belt-Drive Wall-Mount Exhaust Fans with Louvers
These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area. Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.

For Opening | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Housing Material | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
Totally Enclosed Motor Enclosure | |||||||||||||||||||
230/460V AC, Three Phase—Hardwire | |||||||||||||||||||
30" | 6,000 | 55 dB @ 5 ft. | 550 | 1 | 1/2 | 37" | 37" | 36 1/2" | 36 1/2" | 25" | 153 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 000000000 |
36" | 8,100 | 53 dB @ 5 ft. | 400 | 1 | 1/2 | 43" | 43" | 42 1/2" | 42 1/2" | 25" | 225 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 00000000 |
42" | 11,000 | 57 dB @ 5 ft. | 400 | 1 | 3/4 | 49" | 49" | 48 1/2" | 48 1/2" | 25" | 250 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 00000000 |
48" | 14,900 | 57 dB @ 5 ft. | 350 | 1 | 1 | 55" | 55" | 54 1/2" | 54 1/2" | 25" | 324 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 00000000 |