Insect Screening
All screening resists corrosion.
Fiberglass won’t crease or dent.
316 stainless steel and bronze have superior corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Wd. | Mesh Size | Wire Dia. | Choose a Finish | 7-ft. Lg. | 25-ft. Lg. | 100-ft. Lg. | |
Aluminum | |||||||
---|---|---|---|---|---|---|---|
24" | 16 × 18 | 0.011" | 0000000 | ||||
30" | 16 × 18 | 0.011" | 0000000 | ||||
36" | 16 × 18 | 0.011" | 0000000 | ||||
42" | 16 × 18 | 0.011" | 0000000 | ||||
48" | 16 × 18 | 0.011" | 0000000 | ||||
60" | 16 × 18 | 0.011" | 0000000 | ||||
Fiberglass | |||||||
24" | 16 × 18 | 0.011" | 0000000 | ||||
30" | 16 × 18 | 0.011" | Dark Gray | 0000000 | |||
36" | 16 × 18 | 0.011" | 0000000 | ||||
42" | 16 × 18 | 0.011" | 0000000 | ||||
48" | 16 × 18 | 0.011" | 0000000 | ||||
60" | 16 × 18 | 0.011" | 0000000 | ||||
Steel | |||||||
24" | 14 × 18 | 0.009" | Zinc-Plated | 0000000 | |||
30" | 14 × 18 | 0.009" | Zinc-Plated | 0000000 | |||
36" | 14 × 18 | 0.009" | Zinc-Plated | 0000000 | |||
48" | 14 × 18 | 0.009" | Zinc-Plated | 0000000 | |||
304 Stainless Steel | |||||||
24" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
36" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
48" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
316 Stainless Steel | |||||||
24" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
36" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
48" | 18 × 18 | 0.009" | Unfinished | 0000000 | |||
Bronze | |||||||
24" | 14 × 18 | 0.011" | Unfinished | 0000000 | |||
36" | 14 × 18 | 0.011" | Unfinished | 0000000 | |||
48" | 14 × 18 | 0.011" | Unfinished | 0000000 |
Air Curtains
Produce a stream of air down a doorway or other opening to keep out dust, dirt, insects, and fumes while allowing personnel to pass through. These air curtains have wire leads for hardwiring.
Air curtains with HEPA filters trap 99.9% of airborne contaminants as small as .3 microns, including bacteria. MERV-rated pre-filters capture particles as small as 3 microns, including mold spores, pet dander, and cement dust.
Optional door switches turn air curtains on when the door is opened and off when it is closed.
For Frame Opening | O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Wd. | Ht. | Dp. | Airflow, cfm | Volume | No. of Motors | Power per Motor, hp | Current, A | Specifications Met | For Use Outdoors | Temp. Range, °F | Each | ||
120V AC | |||||||||||||||
36" | 120" | 36" | 10 5/8" | 24 1/8" | 1,172 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 000000000 |
42" | 120" | 42" | 10 5/8" | 24 1/8" | 1,205 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 0000000 | 00000000 |
48" | 120" | 48" | 10 5/8" | 24 1/8" | 970 | 66 dBA @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
60" | 120" | 60" | 10 5/8" | 24 1/8" | 2,295 | 68 dBA @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
72" | 120" | 72" | 10 5/8" | 24 1/8" | 2,344 | 68 dBA @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
Optional Door Switch | 000000 | Each | 0000000 |