Application Application | Show |
---|
|
Application Application | Hide |
---|
|
Garment Garment |
---|
|
|
Flame-Resistant Application Flame-Resistant Application |
---|
|
Coating Material Coating Material |
---|
|
Cuff Style Cuff Style |
---|
![]() | Hook and Loop |
Closure Type Closure Type |
---|
|
Height Height |
---|
|
Safety Toe Material Safety Toe Material |
---|
|
Toe Type Toe Type |
---|
|
Men's Shoe Size Men's Shoe Size |
---|
|
|
|
Women's Shoe Size Women's Shoe Size |
---|
|
|
|
Jacket Style Jacket Style |
---|
|
More
These suits meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These suits are made of PVC-coated Nomex aramid. Jackets have snaps down the front and a storm flap to keep rain out. Sleeves have hook and loop cuffs; tighten to fit your wrist or expand to wear over gloves. The bib overalls have adjustable suspenders to modify the length.
When measuring chest size, measure around the fullest part of your chest. Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these suits.
Available Sizes | |||
---|---|---|---|
Size | Chest Size | Waist Size | Inseam Lg. |
S | 46" | 42" | 28" |
M | 50" | 46" | 29" |
L | 54" | 50" | 30" |
XL | 58" | 54" | 31" |
2XL | 62" | 58" | 32" |
3XL | 66" | 62" | 32" |
Material | Coating Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Closure Type | Cuff Style | Specifications Met | Color | Choose a Size | Each | |
Suit | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nomex Aramid Fabric | PVC Plastic | 14 | 2 | Snaps | Hook and Loop | NFPA 70E, ASTM F2733 | Blue | 0000000 | 0000000 | |
Suit with Detachable Hood | ||||||||||
Nomex Aramid Fabric | PVC Plastic | 14 | 2 | Snaps | Hook and Loop | NFPA 70E, ASTM F2733 | Blue | 0000000 | 000000 |
These jackets meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These jackets are made of PVC-coated Nomex aramid. They have snaps down the front and a storm flap to keep rain out. They have hook and loop cuffs; tighten to fit your wrist or gloves.
Fasten a hood (sold separately) to the collar snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these jackets.
Available Sizes | ||
---|---|---|
Size | Chest Size | Lg. |
S | 46" | 29" |
M | 50" | 30" |
L | 54" | 31" |
XL | 58" | 31" |
2XL | 62" | 32" |
3XL | 66" | 32" |
These overalls meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These overalls are made of PVC-coated Nomex aramid. They have hook and loop closures on the cuffs and adjustable suspenders to modify the length.
Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these overalls.
Available Sizes | ||
---|---|---|
Size | Waist Size | Inseam Lg. |
S | 32"-34" | 28" |
M | 36"-38" | 29" |
L | 40"-42" | 30" |
XL | 44"-46" | 31" |
2XL | 48"-50" | 32" |
3XL | 52"-54" | 32" |
Also known as firefighters' boots, these meet the NFPA 1971 standard for structural firefighting. They have a Kevlar lining throughout and a foam insole to withstand ambient heat up to 500° F. These boots are knee high and made of water-resistant blended rubber. They have a safety toe that meets ASTM F2413 standards for protection against impact and compression. A shank provides arch support by distributing weight during strenuous work, such as climbing ladders.
Footwear Size Conversion | |
---|---|
Men's Shoe Size | Women's Shoe Size |
5 | 7 |
5 1/2 | 7 1/2 |
6 | 8 |
6 1/2 | 8 1/2 |
7 | 9 |
7 1/2 | 9 1/2 |
8 | 10 |
8 1/2 | 10 1/2 |
9 | 11 |
9 1/2 | 11 1/2 |
10 | 12 |
10 1/2 | 12 1/2 |
11 | 13 |
11 1/2 | 13 1/2 |
12 | 14 |
12 1/2 | 14 1/2 |
13 | 15 |
13 1/2 | 15 1/2 |
14 | 16 |
14 1/2 | 16 1/2 |
15 | 17 |
Material | Ht. | Toe Type | Safety Toe Material | Shank Material | Max. Temp., °F | Specifications Met | Features | Color | Choose a Men's Shoe Size | Pair | |
Blended Rubber | 14" | Safety | Steel | Steel | 500° | ASTM F2413, NFPA 1971 | Kevlar Lining, Foam Insoles | Black | 000000 | 0000000 |