For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Thread Type Thread Type |
---|
Flow Measurement Scale Flow Measurement Scale |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Connection Style Connection Style |
---|
![]() | Threaded |
Seal Material Seal Material |
---|
|
Direction of Flow Direction of Flow |
---|
|
Connection Type Connection Type |
---|
![]() | Pipe |
Maximum Pressure Maximum Pressure |
---|
|
Gender Gender |
---|
|
Body Material Body Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Mounting Location Mounting Location |
---|
|
Maximum Total Volume Maximum Total Volume |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Flowmeter/Totalizers for Oil and Fuel
Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They display a batch total volume that can be reset after each metering application and a total flow volume that cannot be reset. All flowmeter/totalizers are FM approved for Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. They have an enclosure that meets NEMA 4 for protection from dirt and washdowns.
Certificate of calibration traceable to NIST states that the flowmeter/totalizer has passed a test for accuracy.
Optional remote panel-mounting kit lets you mount the meter’s display up to 100 feet away. It includes a sensor module and 10 feet of cable with wire leads.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.

Flowmeter/Totalizers | Replacement Displays | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | End-to-End Lg. | Flow Range, gpm | Accuracy | Max. Total Volume, units | Max. Pressure | Mounting Orientation | Batteries Included | Each | Each | ||
Flowmeter/Totalizers | |||||||||||
Gallons per Minute, Liters per Minute | |||||||||||
1 NPT Female | 4" | 0.3 to 3 | ±5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 0000000 | 00000000 | 0000000 |
1 NPT Female | 4" | 3 to 50 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 6" | 30 to 300 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 00000000 | 00000000 | 000000 |
Flowmeter/Totalizers with Certificate of Calibration Traceable to NIST | |||||||||||
Gallons per Minute, Liters per Minute | |||||||||||
1 NPT Female | 4" | 0.3 to 3 | ±5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 000000 | 00000000 | 000000 |
1 NPT Female | 4" | 3 to 50 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 6" | 30 to 300 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 00000000 | 00000000 | 00000000 | 000000 |
Totalizers for Fuel

Measure the total flow volume of gasoline, diesel fuel, and kerosene. These totalizers automatically reset to zero when they reach the maximum reading.
Pipe Connections | End-to-End Lg. | Flow Range | Accuracy | Max. Total Volume | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Batteries Included | Each | |
Aluminum Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Gallons | |||||||||||
1 NPT Female | 4" | 3 to 30 gpm | ±5% | 9,999 gallons | 300 psi @ 70° F | 14° to 130° | 316 Stainless Steel | Horizontal, Vertical | Yes | 0000000 | 0000000 |
Liters | |||||||||||
1 NPT Female | 4" | 10 to 100 lpm | ±5% | 9,999 liters | 300 psi @ 70° F | 14° to 130° | 316 Stainless Steel | Horizontal, Vertical | Yes | 0000000 | 000000 |
High-Accuracy Totalizers for Fuel

More than twice as accurate as standard totalizers for fuel, these measure the total flow volume of gasoline, diesel fuel, and kerosene with ±2% accuracy. They display a resettable batch total volume to keep track of one metering application and a nonresettable total flow volume. The mesh strainer traps debris.
Pipe Connections | Flow Range | Accuracy | Max. Total Volume | Max. Batch Volume | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Display Type | Ht. | Wd. | Dp. | Features | Each | |
Aluminum Body | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gallons | |||||||||||||||
1 NPT Female | 5 to 30 gpm | ±2% | 999,999.9 gallons | 999.9 | 50 psi @ 70° F | -20° to 125° | Buna-N Rubber | Horizontal, Vertical | Analog | 8" | 6" | 5 1/4" | Mesh Strainer, Resettable Batch Function | 0000000 | 0000000 |
Liters | |||||||||||||||
1 NPT Female | 19 to 114 lpm | ±2% | 999,999.9 liters | 999.9 | 50 psi @ 70° F | -20° to 125° | Buna-N Rubber | Horizontal, Vertical | Analog | 8" | 6" | 5 1/4" | Mesh Strainer, Resettable Batch Function | 0000000 | 000000 |