For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Flow Measurement Scale Flow Measurement Scale |
---|
|
Thread Type Thread Type |
---|
|
Body Material Body Material |
---|
|
Connection Style Connection Style |
---|
![]() | Threaded |
Direction of Flow Direction of Flow |
---|
|
Environmental Rating Environmental Rating |
---|
Mounting Orientation Mounting Orientation |
---|
|
Mounting Location Mounting Location |
---|
|
Seal Material Seal Material |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Connection Type Connection Type |
---|
![]() | Pipe |
Gender Gender |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Total Volume Maximum Total Volume |
---|
|
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They display a batch total volume that can be reset after each metering application and a total flow volume that cannot be reset. All flowmeter/totalizers are FM approved for Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. They have an enclosure that meets NEMA 4 for protection from dirt and washdowns.
Certificate of calibration traceable to NIST states that the flowmeter/totalizer has passed a test for accuracy.
Optional remote panel-mounting kit lets you mount the meter’s display up to 100 feet away. It includes a sensor module and 10 feet of cable with wire leads.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Flowmeter/Totalizers | Replacement Displays | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | End-to-End Lg. | Flow Range, gpm | Accuracy | Max. Total Volume, units | Max. Pressure | Mounting Orientation | Batteries Included | Each | Each | ||
Flowmeter/Totalizers | |||||||||||
Aluminum Body with 316 Stainless Steel Seal—14° to 140° F | |||||||||||
Gallons per Minute, Liters per Minute | |||||||||||
1 NPT Female | 4" | 0.3 to 3 | ±5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 0000000 | 00000000 | 0000000 |
1 NPT Female | 4" | 3 to 50 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 6" | 30 to 300 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 00000000 | 00000000 | 000000 |
Flowmeter/Totalizers with Certificate of Calibration Traceable to NIST | |||||||||||
Aluminum Body with 316 Stainless Steel Seal—14° to 140° F | |||||||||||
Gallons per Minute, Liters per Minute | |||||||||||
1 NPT Female | 4" | 0.3 to 3 | ±5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 000000 | 00000000 | 000000 |
1 NPT Female | 4" | 3 to 50 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 000000 | 00000000 | 000000 |
2 NPT Female | 6" | 30 to 300 | ±1.5% | 999,999 | 300 psi @ 70° F | Horizontal, Vertical | Yes | 0000000 | 00000000 | 00000000 | 000000 |
More than twice as accurate as standard totalizers for fuel, these measure the total flow volume of gasoline, diesel fuel, and kerosene with ±2% accuracy. They display a resettable batch total volume to keep track of one metering application and a nonresettable total flow volume. The mesh strainer traps debris.
Pipe Connections | Flow Range | Accuracy | Max. Total Volume | Max. Batch Volume | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Display Type | Ht. | Wd. | Dp. | Features | Each | |
Aluminum Body | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gallons | |||||||||||||||
1 NPT Female | 5 to 30 gpm | ±2% | 999,999.9 gallons | 999.9 | 50 psi @ 70° F | -20° to 125° | Buna-N Rubber | Horizontal, Vertical | Analog | 8" | 6" | 5 1/4" | Mesh Strainer, Resettable Batch Function | 0000000 | 0000000 |
Liters | |||||||||||||||
1 NPT Female | 19 to 114 lpm | ±2% | 999,999.9 liters | 999.9 | 50 psi @ 70° F | -20° to 125° | Buna-N Rubber | Horizontal, Vertical | Analog | 8" | 6" | 5 1/4" | Mesh Strainer, Resettable Batch Function | 0000000 | 000000 |
Measure the total flow volume of gasoline, diesel fuel, and kerosene. These totalizers automatically reset to zero when they reach the maximum reading.
Pipe Connections | End-to-End Lg. | Flow Range | Accuracy | Max. Total Volume | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Batteries Included | Each | |
Aluminum Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Gallons | |||||||||||
1 NPT Female | 4" | 3 to 30 gpm | ±5% | 9,999 gallons | 300 psi @ 70° F | 14° to 130° | 316 Stainless Steel | Horizontal, Vertical | Yes | 0000000 | 0000000 |
Liters | |||||||||||
1 NPT Female | 4" | 10 to 100 lpm | ±5% | 9,999 liters | 300 psi @ 70° F | 14° to 130° | 316 Stainless Steel | Horizontal, Vertical | Yes | 0000000 | 000000 |