Small enough to carry from job to job.
Stainless steel cleaner offers greater cleaning capacity than the plastic cleaner because it includes an after-filter. It cannot be sold in California.
Add duct (sold separately) to the plastic cleaner to exhaust filtered air outside of the space that you are cleaning.
For Duct | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Includes | For Removing | Each | |
500 | 62 dB @ 15 ft. | 1/2 | 120V AC | 3A | 12" | 8" | 24 3/4" | 26 1/4" | 18 1/4" | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles, Odors and Fumes | 00000000 | 000000000 |
For Duct | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Inlet Wd. | Inlet Ht. | Outlet Dia. | Ht. | Wd. | Dp. | Includes | For Removing | Each | |
500 | 60 dB @ 15 ft. | 1/2 | 120V AC | 7A | 12" | 12" | 10" | 14" | 14" | 35" | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 000000000 |
Carry these cleaners from job to job.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
110 | 75 dB @ 15 ft. | 1/4 | 120V AC | 7A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 000000000 |
225 | 75 dB @ 15 ft. | 1/2 | 120V AC | 14A | 2 1/4" | 17" | 23 1/2" | 12" | Steel | 12 | Rubber | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Odors and Fumes | 0000000 | 00000000 |
These air cleaners roll to where you need them.
They cannot be sold in California.
For Inlet Duct | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | Wd. | Ht. | For Outlet Duct Dia. | Ht. | Wd. | Dp. | No. of Speeds | Includes | For Removing | Each | |
2,000 | 64 dB @ 15 ft. | 3/4 | 120V AC | 15A | 24" | 25" | 12" | 31" | 26" | 42" | Three | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 000000000 |
4,000 | 64 dB @ 15 ft. | 2 | 120V AC | 26A | 24" | 44" | 18" | 48" | 26" | 46" | One | Disposable After-Filter, Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Prefilter | Dust and Particles | 0000000 | 00000000 |
Roll this air cleaner to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air cleaning booth.
Includes a prefilter; all other filters sold separately.
Standard filter captures 95% of particles down to 3 microns.
HEPA filter captures 99.97% of particles down to 0.3 microns.
Odor-removal filter has carbon to remove odors. It includes a pleated filter that captures 60% of particles down to 3 microns.
Add an odor-removal after-filter to standard and HEPA filters for light duty odor control.
Overall | Hose | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Power, hp | Voltage | Current | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Includes | For Removing | Each | |
350 | 58 dB @ 15 ft. | 1/4 | 120V AC | 2.8A | 2 1/2" | 19 1/2" | 12 1/2" | 12 1/2" | Powder-Coated Steel | 4 | Plastic | Disposable Prefilter, Plastic Hood | Dust and Particles, Odors and Fumes | 0000000 | 000000000 |
Odor-Removal After-Filters | 0000000 | Each | 0000000 |
Odor-Removal Filters | 0000000 | Each | 000000 |
Replacement Prefilters (Pkg. of 4) | 0000000 | Pkg. | 00000 |
HEPA Filters | 0000000 | Each | 000000 |
Standard Filters | 0000000 | Each | 000000 |
Replacement Pleated Filters for Odor-Removal Filters and After-Filters | 0000000 | Each | 00000 |
Replacement Carbon for Odor-Removal Filters | 0000000 | Each | 000000 |
Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a pre-filter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Class 100 (Fed. Std.) and Class 5 (ISO) clean room requirements.
As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
Hoods with an ultraviolet light disinfect the inside of their enclosure as well as any tools and material within it, which helps you maintain a sterile environment for bioprocessing applications. You can also use them to disinfect samples in preparation for thermal stress tests. To protect you from the harmful UV rays, these hoods have a thick synthetic glass front panel that fully closes. When you open the panel, the UV light automatically shuts off.
For technical drawings and 3-D models, click on a part number.
Overall | Work Surface | Housing | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Wavelength, nm | Ht. | Wd. | Dp. | Wd. | Dp. | Material | Color | Panel Cutout Dia. | Each | |
304L Stainless Steel Work Surface with Acrylic Enclosure | ||||||||||||||
Hoods | ||||||||||||||
185 | 59 dB @ 5 ft. | 120V AC | 3A | __ | 47 3/4" | 31 3/4" | 24 1/4" | 26 1/2" | 20 1/2" | Plastic | Black, Blue, White | 2 7/8" | 0000000 | 000000000 |
Hoods with Ultraviolet Light | ||||||||||||||
115 | 54 dB @ 5 ft. | 120V AC | 3A | 254 | 38" | 31 3/4" | 26 1/2" | 26 1/2" | 20 1/2" | Plastic | Black, Purple, White | 2 7/8" | 0000000 | 00000000 |
Use in less demanding environments. This cleaner requires three HEPA filters (included).
Overall | Housing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Material | Color | Includes | For Removing | Each | |
330 | 46 dB @ 15 ft. | 120V AC | 1.2A | 22 1/4" | 20" | 10 3/4" | Plastic | Black | Disposable HEPA Filter (Captures 99.97% of particles down to 0.3 microns), Disposable Odor-Removal Filter | Dust and Particles, Odors and Fumes | 00000000 | 0000000 |
Save floor space—cleaners mount in a T-bar style ceiling to remove contaminants.
These cleaners cannot be sold in California.
Reusable prefilter can be washed.
For Ceiling Tile | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Lg. | Wd. | Lg. | Ht. | Wd. | Housing Material | Includes | For Removing | Each | |
White Housing | |||||||||||||
800 | 43 dB @ 15 ft. | 120V AC | 5A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | 0000000 | 000000000 |
Black Housing | |||||||||||||
800 | 43 dB @ 15 ft. | 120V AC | 5A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | 0000000 | 00000000 |
Remove viruses, bacteria, dust, and other particles from the air. First, the UV-C light bulbs in these cleaners kill airborne pathogens with UV Germicidal Irradiation (UVGI). Each bulb has been individually tested to ensure that it doesn’t produce harmful ozone. Then, a series of filters remove microbes from the air. To protect more advanced filters, a prefilter traps larger particles. A HEPA filter then captures particles as small as 0.3 microns. With the equivalent of a MERV 17 filter rating, HEPA filters are often used to purify air in hospitals. After the cleaners disinfect and filter air, a multispeed blower circulates the clean air throughout your space.
Cleaners with a carbon filter eliminate odors and fumes. They’re commonly used to absorb harmful vapors in laboratories. These cleaners cannot be sold to California.
Freestanding air cleaners are easily moved from room to room, allowing you to use them wherever they’re needed at a moment’s notice. Cleaners that are portable include eye bolts for mounting them to a ceiling with a chain. They perform up to six air changeovers per hour in a 30 ft. × 30 ft. space. Cleaners that are mobile have wheels to make them easier to move. CARB compliant, they’re tested for electrical safety and ozone-emission concentration limits. Their prefilter uses magnesium oxide, zinc oxide, and titanium dioxide to neutralize the chemicals in vapors and fumes, instead of simply absorbing them like carbon filters. These cleaners complete between three and five air changeovers per hour in a 1,000 sq. ft. space. Indicator lights alert you when it’s time to replace their air filters and UV bulbs.
Ceiling-mount air cleaners rest flush with your ceiling, blending into the room without taking up floor space. Install them on a 24 in. × 48 in. ceiling tile with the mounting frame, or use a chain and the included eyebolts to mount them elsewhere. Set different airflow patterns with the adjustable louver blades. A hinged panel lets you access and replace filters without having to remove these cleaners from the ceiling. Ceiling-mount air cleaners provide up to six air changeovers per hour in a 27 ft. × 27 ft. space.
Air Cleaners | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA/Odor-Removal Filters | Replacement Bulbs | |||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Housing Material | Each | Each | Each | |||
White Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | Steel | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 000000 |
Black Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | Steel | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 00000 |
Air Cleaners | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA Filters | Replacement Prefilters | Replacement Bulbs | ||||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Housing Material | Features | Specifications Met | Each | Each | Each | Each | ||||
White Housing—With Reusable HEPA Filter, Reusable Prefilter, Thumb Screws | |||||||||||||||||
250 | 62 dB @ 15 ft. | 120V AC | 1 | 15" | 22" | 15 1/2" | Steel | Indicator Lights, Wheels | CARB Compliant | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
Air Cleaners | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | For Ceiling Tile | Replacement Prefilters | Replacement Bulbs | ||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Length | Width | Housing Material | Each | Each | Each | |||
White Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||||
600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | Steel | 0000000 | 000000000 | 0000000 | 000000 | 0000000 | 000000 |
Black Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | |||||||||||||||
600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | Steel | 0000000 | 00000000 | 0000000 | 00000 | 0000000 | 00000 |
Draw particles and filament fumes away from open-frame 3D printers without cooling off printed parts. Unlike standard air cleaners, which create airflow strong enough to cool the print area and warp your parts, these low-airflow cleaners won’t disrupt your print. A three-part filtering process keeps you from breathing harmful emissions: a prefilter traps large particles, then a combination HEPA and activated carbon filter captures both fine particles and fumes. These CE marked cleaners meet health, safety, and environmental protection standards for products.
Attach the included hose and funnel to the cleaner to pull fumes directly from your printer. These compact, lightweight cleaners fit into most work areas, and are quiet enough for office use. The powder-coated steel housing holds up over a long service life.
Overall | Hose | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Current, A | Voltage | For Inlet Duct Dia. | Ht. | Wd. | Dp. | Housing Material | Lg., ft. | Material | Cord Lg., ft. | Includes | Each | |
26 | 44 dB @ 3 ft. | 0.2 | 120V AC | 2" | 13 1/4" | 11 1/4" | 11" | Powder-Coated Steel | 6 | Plastic | 6 | Combination HEPA/Chemical Filter (Captures 99.99% of particles down to 0.03 microns), Disposable Prefilter | 0000000 | 0000000 |
Produce a stream of air down a doorway or other opening to keep out dust, dirt, insects, and fumes while allowing personnel to pass through. These air curtains have wire leads for hardwiring.
Air curtains with HEPA filters trap 99.9% of airborne contaminants as small as .3 microns, including bacteria. MERV-rated pre-filters capture particles as small as 3 microns, including mold spores, pet dander, and cement dust.
Optional door switches turn air curtains on when the door is opened and off when it is closed.
For Frame Opening | O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Wd. | Ht. | Dp. | Airflow, cfm | Volume | No. of Motors | Power per Motor, hp | Current, A | Specifications Met | For Use Outdoors | Temp. Range, °F | Each | ||
120V AC | |||||||||||||||
36" | 120" | 36" | 10 5/8" | 24 1/8" | 1,172 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 000000000 |
42" | 120" | 42" | 10 5/8" | 24 1/8" | 1,205 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 0000000 | 00000000 |
48" | 120" | 48" | 10 5/8" | 24 1/8" | 970 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
60" | 120" | 60" | 10 5/8" | 24 1/8" | 2,295 | 68 dB @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
72" | 120" | 72" | 10 5/8" | 24 1/8" | 2,344 | 68 dB @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° | 100° | 00000000 | 00000000 |
Optional Door Switch | 000000 | Each | 000000 |