Selecting Clamps Using Pipe, Conduit, or Tubing Trade Size
More
About Conduit
More
Snug-Hold Threaded-Rod-Mount Clamping Hangers

Load material between the two halves of the ring and adjust the side bolts for a tighter fit than standard threaded-rod-mount clamping hangers and loop hangers. All have a threaded hole on top for mounting with threaded rod.
Zinc-plated iron hangers have mild corrosion resistance.
Copper-plated iron hangers are corrosion resistant and can be used with copper tubing.
For technical drawings and 3-D models, click on a part number.
ID | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Inch | Metric, mm | For Pipe Size | For Thread Size | Cap., lbs. | Lg. | Wd. | Ht. | Mounting Hole Dia. | Specifications Met | Each | |
Iron | |||||||||||
11/16" | 17 | 3/8 | 3/8"-16 | 180 | 1 13/16" | 9/16" | 1 3/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
7/8" | 22 | 1/2 | 3/8"-16 | 180 | 2 1/16" | 9/16" | 1 3/8" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 1/16" | 27 | 3/4 | 3/8"-16 | 180 | 2 1/4" | 9/16" | 1 9/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 5/16" | 33 | 1 | 3/8"-16 | 180 | 2 11/16" | 9/16" | 1 15/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 11/16" | 43 | 1 1/4 | 3/8"-16 | 180 | 3" | 9/16" | 2 5/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
1 7/8" | 48 | 1 1/2 | 3/8"-16 | 180 | 3 5/16" | 9/16" | 2 9/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
2 3/8" | 60 | 2 | 3/8"-16 | 180 | 3 13/16" | 9/16" | 3" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
2 7/8" | 73 | 2 1/2 | 1/2"-13 | 300 | 4 3/4" | 11/16" | 3 15/16" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
3 1/2" | 89 | 3 | 1/2"-13 | 300 | 5 9/16" | 13/16" | 4 5/16" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
4 1/2" | 114 | 4 | 1/2"-13 | 300 | 6 11/16" | 13/16" | 5 1/2" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
Zinc-Plated Iron | |||||||||||
11/16" | 17 | 3/8 | 3/8"-16 | 180 | 1 13/16" | 9/16" | 1 3/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
7/8" | 22 | 1/2 | 3/8"-16 | 180 | 2 1/16" | 9/16" | 1 3/8" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 1/16" | 27 | 3/4 | 3/8"-16 | 180 | 2 1/4" | 9/16" | 1 9/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 5/16" | 33 | 1 | 3/8"-16 | 180 | 2 11/16" | 9/16" | 1 15/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 0000 |
1 11/16" | 43 | 1 1/4 | 3/8"-16 | 180 | 3" | 9/16" | 2 5/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
1 7/8" | 48 | 1 1/2 | 3/8"-16 | 180 | 3 5/16" | 9/16" | 2 9/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
2 3/8" | 60 | 2 | 3/8"-16 | 180 | 3 13/16" | 9/16" | 3" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
2 7/8" | 73 | 2 1/2 | 1/2"-13 | 300 | 4 3/4" | 11/16" | 3 15/16" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
3 1/2" | 89 | 3 | 1/2"-13 | 300 | 5 9/16" | 13/16" | 4 5/16" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
4 1/2" | 114 | 4 | 1/2"-13 | 300 | 6 11/16" | 13/16" | 5 1/2" | 1/2" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
Copper-Plated Iron | |||||||||||
1/2" | 12 | __ | 3/8"-16 | 180 | 1 11/16" | 9/16" | 1" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
5/8" | 15 | __ | 3/8"-16 | 180 | 1 3/4" | 9/16" | 1 1/4" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
7/8" | 22 | __ | 3/8"-16 | 180 | 1 15/16" | 9/16" | 1 1/2" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
1 1/8" | 28 | __ | 3/8"-16 | 180 | 2 1/4" | 9/16" | 1 13/16" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
1 3/8" | 34 | __ | 3/8"-16 | 180 | 2 5/8" | 9/16" | 2" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
1 5/8" | 41 | __ | 3/8"-16 | 180 | 2 15/16" | 9/16" | 2 1/4" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
2 1/8" | 53 | __ | 3/8"-16 | 180 | 3 7/16" | 9/16" | 2 3/4" | 3/8" | Fed. Spec. WW-H-171E, Type 25; MSS-SP-58-2009, Type 12 | 0000000 | 00000 |
Adapters for Medium-Wall (IMC) and Thick-Wall (Rigid) Steel Conduit
Attach medium-wall (IMC) and thick-wall (rigid) steel conduit to a knockout in an outlet box or enclosure.
NPSM female × NPSM male 90° elbow adapters are for tight spaces where conduit can't be bent.
For technical drawings and 3-D models, click on a part number.

Conduit Connection | Electrical Box Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Material | Specifications Met | Each | |
1/2 | 1/2 | NPSM | Female | 1/2 | NPSM | Male | Iron | UL Listed | 0000000 | 00000 |
3/4 | 3/4 | NPSM | Female | 3/4 | NPSM | Male | Iron | UL Listed | 0000000 | 0000 |
1 | 1 | NPSM | Female | 1 | NPSM | Male | Iron | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPSM | Female | 1 1/4 | NPSM | Male | Iron | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPSM | Female | 1 1/2 | NPSM | Male | Iron | UL Listed, CSA Certified | 0000000 | 000000 |
2 | 2 | NPSM | Female | 2 | NPSM | Male | Iron | UL Listed, CSA Certified | 0000000 | 000000 |
Connectors for Medium-Wall (IMC) and Thick-Wall (Rigid) Steel Conduit
Join pieces of medium-wall (IMC) and thick-wall (rigid) conduit.
NPT female straight connectors with glide insert have three pieces. The two outer pieces turn independently so you don't need to rotate the conduit.
For technical drawings and 3-D models, click on a part number.

Conduit Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Pipe Size | Thread Type | Gender | Material | Features | Specifications Met | Each | |
Connector with Glide Insert | ||||||||
1/2 | 1/2 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 00000 |
3/4 | 3/4 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 0000 |
1 | 1 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 00000 |
2 | 2 | NPT | Female | Zinc-Plated Iron | Glide Insert | UL Listed | 0000000 | 00000 |
Conduit Adapters

Transition between types of metal conduit. The twist-in end attaches to conduit with a few quick turns.
For technical drawings and 3-D models, click on a part number.
Adapters for Flexible Metal Conduit
Attach flexible metal conduit to a knockout in an outlet box or enclosure. The screw-clamp end tightens around conduit with a screw. Iron adapters are stronger and more durable than zinc adapters.
For technical drawings and 3-D models, click on a part number.

Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
1/2 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 0000 |
3/4 | Female | 3/4 | NPSM | Male | UL Listed | 0000000 | 0000 |
1 | Female | 1 | NPT | Male | UL Listed | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPT | Male | UL Listed | 0000000 | 00000 |
1 1/2 | Female | 1 1/2 | NPT | Male | UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPT | Male | UL Listed | 0000000 | 00000 |

Conduit Connection | Electrical Box Connection | ||||||
---|---|---|---|---|---|---|---|
Conduit Trade Size | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Screw-Clamp Conduit Connection × Threaded Electrical Box Connection | |||||||
3/8 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
1/2 | Female | 1/2 | NPSM | Male | UL Listed | 0000000 | 0000 |
3/4 | Female | 3/4 | NPSM | Male | UL Listed | 0000000 | 00000 |
1 | Female | 1 | NPSM | Male | UL Listed | 0000000 | 00000 |
1 1/4 | Female | 1 1/4 | NPSM | Male | UL Listed | 0000000 | 00000 |
1 1/2 | Female | 1 1/2 | NPSM | Male | UL Listed | 0000000 | 00000 |
2 | Female | 2 | NPSM | Male | UL Listed | 0000000 | 00000 |
Fittings for Liquid-Tight Flexible Metal Conduit
When used to connect liquid-tight flexible metal conduit to a knockout in an outlet box or enclosure, these fittings seal out liquids. Attach the twist-in end to conduit with a few quick turns.
Adapters with grounding lug ground conduit outside an outlet box or enclosure. Run a ground wire through the lug. Adapters with a wire-mesh grip provide strain relief and added protection against conduit pullout.These fittings seal out liquids when connecting liquid-tight flexible metal conduit to a knockout in an outlet box or enclosure.
For technical drawings and 3-D models, click on a part number.

Grounding
Lug and Locknut
Conduit Connection | Electrical Box Connection | |||||||
---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Pipe Size | Thread Type | Gender | Specifications Met | Each | |
Adapters with Grounding Lug and Locknut—Iron | ||||||||
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | UL Listed, CSA Certified | 0000000 | 000000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Twist-In | Female | 2 | NPT | Male | UL Listed, CSA Certified | 0000000 | 000000 |



Conduit Connection | Electrical Box Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Pipe Size | Thread Type | Gender | Features | Specifications Met | Each | |
Adapters with Locknut—Zinc-Plated Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 000000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Twist-In | Female | 2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
Adapters with Locknut—Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 0000 |
1/2 | Twist-In | Female | 1/2 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 0000 |
3/4 | Twist-In | Female | 3/4 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 00000 |
1 | Twist-In | Female | 1 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 00000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 00000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 00000 |
2 | Twist-In | Female | 2 | NPSM | Male | __ | UL Listed, C-UL Listed | 0000000 | 00000 |
Adapters with Grounding Lug and Locknut—Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 000000 |
2 | Twist-In | Female | 2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 000000 |
Adapters with Wire-Mesh Grip and Locknut—Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | 6" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | 5 1/4" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | 6 1/2" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | 7 3/4" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | 10 5/8" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | 11" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
2 | Twist-In | Female | 2 | NPT | Male | 14" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |



Conduit Connection | Electrical Box Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Conduit Trade Size | Conduit Connection Type | Gender | Pipe Size | Thread Type | Gender | Features | Specifications Met | Each | |
Adapters with Locknut—Zinc-Plated Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 000000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Twist-In | Female | 2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
Adapters with Grounding Lug and Locknut—Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 00000 |
2 | Twist-In | Female | 2 | NPT | Male | __ | UL Listed, CSA Certified | 0000000 | 000000 |
Adapters with Wire-Mesh Grip and Locknut—Iron | |||||||||
3/8 | Twist-In | Female | 1/2 | NPT | Male | 6" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
1/2 | Twist-In | Female | 1/2 | NPT | Male | 5 1/4" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
3/4 | Twist-In | Female | 3/4 | NPT | Male | 6 1/2" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 00000 |
1 | Twist-In | Female | 1 | NPT | Male | 7 3/4" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
1 1/4 | Twist-In | Female | 1 1/4 | NPT | Male | 10 5/8" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
1 1/2 | Twist-In | Female | 1 1/2 | NPT | Male | 11" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
2 | Twist-In | Female | 2 | NPT | Male | 14" lg. Stainless Steel Wire-Mesh Grip | UL Listed, CSA Certified | 00000000 | 000000 |
Access Ports for Metal Conduit
Also known as conduit bodies, these ports provide access to wire and cable inside conduit for pulling, splicing, and maintenance. They are also used to change the direction of a run. Connect to thick-wall (rigid) metal conduit. Aluminum and zinc-plated iron ports can connect to medium-wall (IMC) conduit.
All are corrosion resistant. 316 stainless steel ports offer the best corrosion resistance.
For technical drawings and 3-D models, click on a part number.

Conduit Trade Size | Pipe Size | Thread Type | Gender | Features | Specifications Met | Each | |
Zinc-Plated Iron | |||||||
---|---|---|---|---|---|---|---|
1/2 | 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 | 1 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
2 | 2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |

Conduit Trade Size | Pipe Size | Thread Type | Gender | Features | Specifications Met | Each | |
Zinc-Plated Iron | |||||||
---|---|---|---|---|---|---|---|
1/2 | 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 | 1 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
2 | 2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |

Conduit Trade Size | Pipe Size | Thread Type | Gender | Features | Specifications Met | Each | |
Zinc-Plated Iron | |||||||
---|---|---|---|---|---|---|---|
1/2 | 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |
3/4 | 3/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 | 1 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/4 | 1 1/4 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
1 1/2 | 1 1/2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 00000 |
2 | 2 | NPT | Female | Removable Cover with Rubber Gasket | UL Listed, CSA Certified | 0000000 | 000000 |
Steel and Iron Cord Grips


Stronger than aluminum cord grips, these grips are zinc plated for corrosion resistance. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid.
Locknut and O-ring kits (sold separately) create liquid-tight seals between cord grips and enclosure knockouts. Rated NEMA 4X, NEMA 13, and IP66, the resulting seals provide indoor and outdoor protection against dust, corrosion, water projected from a hose, and oil/coolant spray. Each kit includes two locknuts and two O-rings—enough to seal two cord grips.
For technical drawings and 3-D models, click on a part number.
Cord Grips | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Each | Locknut and O-Ring Kits | |||||||||
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
Zinc-Plated Iron | ||||||||||
1"-1.13" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 000000 |
1"-1.13" | 1 1/2 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 00000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | 0000000 | 00000 |
1.13"-1.25" | 1 1/2 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 00000 |
1.25"-1.38" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | 0000000 | 00000 |
1.25"-1.38" | 1 1/2 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 00000 |
Steel and Iron Wet-Location Cord Grips

Stronger than aluminum cord grips, these grips are zinc plated for corrosion resistance. They have a zinc-plated steel locknut and metal-reinforced rubber O-ring that prevents liquid from entering the connection. All are rated NEMA 4X, NEMA 13, and IP66 to provide indoor and outdoor protection against dust, corrosion, water projected from a hose, and oil/coolant spray.
As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid.
For technical drawings and 3-D models, click on a part number.
Each | ||||||||
---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Features | Specifications Met | 1-9 | 10-Up | |
Zinc-Plated Iron | ||||||||
1"-1.13" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 0000000 | 000000 |
1"-1.13" | 1 1/2 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 000000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 00000 |
1.13"-1.25" | 1 1/2 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 000000 |
1.25"-1.38" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 00000 |
1.25"-1.38" | 1 1/2 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 000000 |