    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    140 amp @ 240V AC120121 hr.Removable2SteelSPST
    9 3/8"5 1/2"3 5/8"Screw Terminal000000000000001 Pair000000000000
    240 amp @ 240V AC120/208/240/2774815 min.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal000000000000———0
    240 amp @ 240V AC120121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
     
    7-Day Timing Cycle
    240 amp @ 240V AC120/208/240/27762 hr.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal00000000000000———0
    440 amp @ 240V AC12033.5 hr.Removable14Steel4PST
    12 1/2"8 1/4"4"Screw Terminal000000000000007 Pair0000000000000
     
    Screws

    Outdoor Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Time and Day Activated Switches, 24-Hr. Timing Cycle.
    Image of Product. Front orientation. Timer Switches. Outdoor Time and Day Activated Switches, 7-Day Timing Cycle.

    24-Hr. Timing Cycle

    7-Day Timing Cycle

    Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
    NEMA 3R Enclosure Rating—NEMA 3R rated switches are protected against falling liquids and light splashing.
    Light Sensor Control—Switches with light sensor control allow one device to be controlled by the presence or absence of light.
    Electrical
    Mounting
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    No. of
    Trippers
    Switching Current
    @ Voltage
    No. of
    Outlets
    Features
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Min. Ht.,
    ft.
    Each
    24-Hr. Timing Cycle—NEMA 3R
    1230TripperRemovable415 amp @ 120V AC2Light Sensor Control9 3/8"5 1/2"3 3/8"Straight Blade32No41/4"00000000000000
     
    7-Day Timing Cycle
    71Push Button15 amp @ 120V AC2Astronomical Timing, Random On/Off Option5 1/8"5 1/4"1 7/8"Straight Blade32No20.31"4.5000000000000
     
    Trippers

    Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    365-Day Timing Cycle—Seven-day/365-day switches can perform a different program each day of the week or year, and compensate for leap year and daylight savings time. Override regular programming for up to 99 holidays for any length of time. They can also be used to activate equipment such as bells and signals for just a few seconds.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup, Lockout
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    00000000000000
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    0000000000000
     
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    0000000000000
     
    7 day—With Battery Backup, Lockout, Day Skipper, Astronomical Timing
    130 amp @ 240V AC120/208/240/27720 per day1Push ButtonPolycarbonate
    SPDT
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    0000000000000
     
    7 day/365 day—With Battery Backup, Lockout, Astronomical Timing
    130 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    00000000000000
    230 amp @ 240V AC120/208/240/2774,000 per yr.1Push ButtonSteelSPDT
    8 5/8"5 3/4"3 5/8"No0.19"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed, CSA Certified
    00000000000000
     

    Switch-Contact-Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Screw On.

    Screw On

    No need for a separate power source—these hour meters are powered by internal batteries that last more than 10 years. Often used where power sources aren’t easily accessible, they work well in remote monitoring systems, industrial equipment, and machinery. Wire the hour meter to a relay or switch on your machine so it can receive signals when the machine is running. The total number of hours is shown on the display. Press a button on the meter to reset the time to zero or connect it to a switch or button to reset it from a distance.
    IP65 Enclosure Rating, NEMA 4X Enclosure Rating, and NEMA 12 Enclosure Rating—Screw on hour meters are IP65, NEMA 4X, and NEMA 12 rated, so they’re protected from dust, water, and splashing oil and coolant.
    UL Recognized Component, C-UL Recognized Component, and CE Marked—These meters are UL recognized, C-UL recognized, and CE marked, so they meet American, Canadian, and European safety standards.
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Features
    Enclosure Rating
    Certification
    Each
    Screw On
     
    Screw-Terminal Wire Connection
    YesUp and Down81.8"0.9"1"1.9"2.1"Battery-Powered Display, Manual Reset Button, Remote ResetIP65, NEMA 4X, NEMA 12
    UL Recognized Component, C-UL Recognized Component, CE Marked
    00000000000000
     

    Panel-Mount Electrically Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style G.

    Screw On

    Style G

    Display running time on a machine so you can schedule preventative maintenance.
    Not Resettable—Non-resettable meters prevent tampering and accidental loss of data.
    NEMA 4X Enclosure Rating—Meters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    For Panel
    Cutout Dia.
    Dp.
    Dia.
    Operating
    Voltage
    Enclosure
    Rating
    Each
    Screw On
     
    0.25" Quick-Disconnect Terminals
    GNoUp62"1.3"2.8"24V ACIP65, NEMA 4X
    0000000000000
    GNoUp62"1.3"2.8"120V ACIP65, NEMA 4X
    000000000000
    GNoUp62"1.3"2.8"230V ACIP65, NEMA 4X
    000000000000
     
    back to top