    Power Pole

    Neutral Pole

    Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Lockout. Front orientation. Disconnect Switches. Panel-Mount Disconnect Switches, Plastic Housing, Lockout, 3 Circuits Controlled.

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Certification—All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled—For 3/8" Dia. Panel Cutouts
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    2 1/2"2 1/2"2"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K241000000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    2 1/2"2 1/2"2"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K24200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 13/16"2 13/16"2 3/8"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K24300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    2 13/16"2 13/16"2 3/8"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K24400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K245000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K246000000
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"2"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K22100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"2"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K22200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"2 3/8"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K22300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"2 3/8"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K22400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K225000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K226000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 3/8" Dia. Panel Cutouts
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    2 1/2"2 1/2"2"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K23100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    2 1/2"2 1/2"2"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K23200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 13/16"2 13/16"2 3/8"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K23300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    2 13/16"2 13/16"2 3/8"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K23400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K235000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"3 3/4"2 11/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K236000000
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"2"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K21100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"2"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K21200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"2 3/8"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K21300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"2 3/8"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K21400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K215000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"2 11/16"5/16"Screw TerminalIP40
    UL Listed, C-UL Listed, CE Marked
    6759K216000000
     
    Accessories and Replacements for Disconnect Switches

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    25600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N110000000
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    32600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N12000000
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N13000000
    3Three (10 hp @ 240V AC)
    Three (20 hp @ 480V AC)
    3 Off
    3PST-NO
    63600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N14000000
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N15000000
    3Three (25 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    125600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N16000000
    3Three (30 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    175600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N17000000
     

    Enclosure Disconnect Switches

    Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Switches with Lockout Only
    Image of Product. 3 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 3 Circuits Controlled.
    Image of Product. 4 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 4 Circuits Controlled.
    Image of Product. Front orientation. Switch Seals. Enclosure Disconnect Switches.

    3 Circuits

    4 Circuits

    Sealing Gaskets

    Mounting Depth—Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Enclosure Rating—All meet at least one safety standard.
    Sealing Gaskets—Use sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
    Switches
    Replacement
    Shafts
    Replacement
    Shaft Bases
    Sealing Gaskets
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure
    Rating
    Each
    Each
    Each
    Each
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K260000007277K160000007277K17000007277K1800000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K27000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K28000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K290000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K310000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K320000007277K16000007277K1700007277K190000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K51000007277K16000007277K1700007277K180000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K52000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K53000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K540000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K550000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K560000007277K16000007277K1700007277K190000
     
    4 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K330000007277K16000007277K1700007277K180000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K340000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K350000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K360000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K370000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K380000007277K16000007277K1700007277K190000
     
    Accessories and Replacements for Disconnect Switches

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K101000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K104000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K105000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K106000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10700000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10800000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10900000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K111000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K112000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1100000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K14000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K15000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K16000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4100000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4200000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4300000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K44000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K45000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N170000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N18000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N19000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N21000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N22000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N23000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N11000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N12000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N13000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N14000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N16000000
     
    Accessories and Replacements for Disconnect Switches

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K511000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K521000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K115000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K512000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K522000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K116000000
     
    Labels

    Undervoltage Disconnect Switches

    Prevent motors and other equipment from overheating or failing from not having enough voltage. When the supply voltage falls below 35% of the rated voltage, these switches will automatically turn off to protect the circuit from undervoltage. Once the power is cut, they'll keep it isolated to prevent accidental startups during inspection and maintenance.
    To prevent unauthorized use of these switches, you can lock them out with a padlock (not included). Even if a padlock blocks them from physically turning off, they’ll disconnect power to the actuator if voltage falls below a safe level.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Undervoltage Disconnect Switches.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Black Actuator
     
    2 Circuits Controlled with Lockout—For 1/2" Dia. Panel Cutouts
    40230Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"3 1/8"5/16"Screw TerminalIP54
    UL Listed, C-UL Listed, CSA Certified
    7772N120000000
     
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 1/2" Dia. Panel Cutouts
    40230Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"3 1/8"5/16"Screw TerminalIP54
    UL Listed, C-UL Listed, CSA Certified
    7772N11000000
     

    Enclosure Door Switches

    Image of Product. Front orientation. Enclosure Door Switches.
    Activate or deactivate fans, lights, and other devices inside your enclosure when you open or close the door. To actuate these switches, push the plunger. They work with most enclosures, since you can slide the housing up to 1 ⅜” to make the switch longer or shorter. Mount screws anywhere along the mounting slots to install.
    1 On Switch Starting Position—1 on switches set off an alarm, light, or other device when you open the door.
    1 Off and 1 On Switch Starting Position—1 off and 1 on switches control two devices at the same time—for example, use them to turn a light on and a fan off when you open the door.
    Switching
    For
    Wire
    No. of Circuits
    Controlled
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Max. Voltage,
    V AC
    Ga.
    No.
    of
    Overall
    Lg.
    Enclosure
    Rating
    Certification
    Each
    Plastic Actuator with Wire Leads
     
    1 On Switch Starting Position
    1Momentary
    2SPST-NC
    825025016 to 1424 1/4"IP20
    CE Marked
    4497N12000000
     
    1 Off and 1 On Switch Starting Position
    2Momentary
    4DPST-1NO/1NC
    825025016 to 1424 1/4"IP20
    CE Marked
    4497N1300000
     

    DIN-Rail Mount Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.

    Power Pole

    Neutral Pole

    Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
    Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Maintained SwitchAbout Maintained Switch
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N11000000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1200000
    506003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1300000
    636003PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1400000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N15000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N16000000
     
    4 Circuits Controlled with Lockout
    256004PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1700000
    326004PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1800000
    506004PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1900000
    636004PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N21000000
    806004PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N22000000
    1006004PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N23000000
     