Body Material Body Material |
---|
|
Ball Material Ball Material |
---|
|
Connection Style Connection Style |
---|
![]() | ![]() |
Threaded | Push to Connect |
![]() | |
Barbed |
Valve Function Valve Function |
---|
|
Actuation Actuation |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
System of Measurement System of Measurement |
---|
|
Seal Material Seal Material |
---|
|
Valve Operation Valve Operation |
---|
|
Seat Material Seat Material |
---|
|
More
More
Install these low-profile valves in tight spots.
Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Port Type | End-to-End Lg. | For Use With | Each | |
Light Gray PVC Plastic Body | ||||||||
---|---|---|---|---|---|---|---|---|
NPT Female × NPT Female | ||||||||
1/2 | 8.1 | 125 psi @ 140° F | 35° to 140° | Standard | 3 5/16" | Water, Air, Argon, Helium, Krypton, Neon, Xenon | 00000000 | 00000 |
NPT Male × NPT Female | ||||||||
1/2 | Not Rated | 125 psi @ 140° F | 35° to 140° | Standard | 3 7/16" | Water, Air, Argon, Helium, Krypton, Neon, Xenon | 00000000 | 0000 |
To ensure consistent and repeatable settings, these valves have color-coded handle threads and numerical markings. One full revolution of the handle reveals a new color to indicate the set point. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. The locking knob handle has a ring that prevents accidental adjustment.
Internal check valves actuate when the pressure changes to stop flow control from the controlled direction and allow free flow in the opposite direction. Valves with an internal check valve are often used to control the speed of air cylinders and air-powered motors.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Valves | Mounting Nuts | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Panel Cutout Dia. | End-to-End Lg. | For Use With | Each | Each | ||
Black Glass-Reinforced Polyester Plastic Body | ||||||||||
NPTF Female × NPTF Female | ||||||||||
1/8 | 0.26 | 200 psi @ 200° F | 0° to 200° | 1" | 1 15/16" | Air, Oxygen | 0000000 | 000000 | 0000000 | 00000 |
1/4 | 0.48 | 200 psi @ 200° F | 0° to 200° | 1" | 1 15/16" | Air, Oxygen | 0000000 | 00000 | 0000000 | 0000 |
3/8 | 1.06 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 2 7/8" | Air, Oxygen | 0000000 | 00000 | 0000000 | 0000 |
1/2 | 1.35 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 2 7/8" | Air, Oxygen | 0000000 | 00000 | 0000000 | 0000 |
3/4 | 1.96 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 3" | Air, Oxygen | 0000000 | 00000 | 0000000 | 0000 |
Black Glass-Reinforced Polyester Plastic Body with Internal Check Valve | ||||||||||
NPTF Female × NPTF Female | ||||||||||
1/8 | 0.26 | 200 psi @ 200° F | 0° to 200° | 1" | 1 15/16" | Air, Oxygen | 00000000 | 00000 | 0000000 | 0000 |
1/4 | 0.48 | 200 psi @ 200° F | 0° to 200° | 1" | 1 15/16" | Air, Oxygen | 00000000 | 00000 | 0000000 | 0000 |
3/8 | 1.06 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 2 7/8" | Air, Oxygen | 00000000 | 00000 | 0000000 | 0000 |
1/2 | 1.35 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 2 7/8" | Air, Oxygen | 00000000 | 00000 | 0000000 | 0000 |
3/4 | 1.96 | 200 psi @ 200° F | 0° to 200° | 1 3/8" | 3" | Air, Oxygen | 00000000 | 00000 | 0000000 | 0000 |
Insert tubing into the fittings on these valves—no heat, solder, or flux required. Valves divert flow between ports in food and beverage tubing lines. Turn the handle to direct flow from the center-port inlet to either side-port outlet. These valves cannot shut off flow. All are standard port, so they slightly restrict flow.
For Tube | Mounting Holes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
ID | OD | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Mounting Fasteners Included | No. of | Thread Size | Each | |
Polypropylene Plastic Body | |||||||||||
Push to Connect × Push to Connect × Push to Connect | |||||||||||
1/8" | 1/4" | L-Pattern | Not Rated | 125 psi @ 140° F | 140° | 2 7/8" | No | 4 | 8-32 | 0000000 | 000000 |
1/4" | 3/8" | L-Pattern | 1.6 | 125 psi @ 140° F | 140° | 2 13/16" | No | 4 | 8-32 | 0000000 | 00000 |
3/8" | 1/2" | L-Pattern | Not Rated | 125 psi @ 140° F | 140° | 3 1/2" | No | 4 | 8-32 | 0000000 | 00000 |
Barbed fittings on these valves grip onto tubing, providing a secure hold. They divert flow between ports in food and beverage tubing lines. Turn the handle to direct flow from the center-port inlet to either side-port outlet. These valves cannot shut off flow. All are standard port, so they slightly restrict flow.
Mounting Holes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Flow Pattern | Flow Coefficient (Cv) | Max. Pressure | Max. Temp., °F | End-to-End Lg. | Mounting Fasteners Included | No. of | Thread Size | Each | |
Polypropylene Plastic Body | ||||||||||
Barbed × Barbed × Barbed | ||||||||||
1/4" | L-Pattern | Not Rated | 125 psi @ 140° F | 140° | 3 1/2" | No | 4 | 8-32 | 0000000 | 000000 |
3/8" | L-Pattern | 1.3 | 125 psi @ 140° F | 140° | 3 1/2" | No | 4 | 8-32 | 0000000 | 00000 |
1/2" | L-Pattern | Not Rated | 125 psi @ 140° F | 140° | 3 1/2" | No | 4 | 8-32 | 0000000 | 00000 |