Timing Adjustment Style Timing Adjustment Style |
---|
![]() | ![]() |
Trippers | Push Button |
Maximum On/Off Cycles Maximum On/Off Cycles |
---|
|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
High-Current Time and Day Activated Switches

Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Environment | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 20 A @ 120 V AC, 208 V AC, 240 V AC, 277 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 0000000 | __ | 000000 | 00 |
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 00000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 20 A @ 240 V AC | 120V AC | 12 per Day | 2 hrs. | Captive | 84 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 00000000 | 000000 | __ | 000000 | 00 |
4 | 40 A @ 240 V AC | 120V AC | 3 per Day | 3.5 hrs. | Removable | 4 | 4PST-NO | 12 1/2" | 8 1/4" | 4" | Screw Terminals | Indoor Only | 00000000 | 000000 | 7 | 00000000 | 00000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Outdoor High-Current Time and Day Activated Switches

Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | SPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 0000000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | 0000000 | 00000 | __ | 000000 | 00 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
7-Day Timing Cycle | |||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 6 per Day | 2 hrs. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | 00000000 | 000000 | __ | 000000 | 00 |
4 | 40 A @ 240 V AC | 120V AC | 3 per Day | 3.5 hrs. | Removable | 14 | Steel | 4PST | 12 1/2" | 8 1/4" | 4" | Screw Terminals | 00000000 | 000000 | 7 | 00000000 | 00000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Set-to-the-Minute High-Current Time and Day Activated Switches

For precise control of high-current equipment such as landscape lighting, pumps, and heaters, these switches schedule on/off times to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have a day skipper that can suspend operation for one to six days. A backup battery maintains the program during a power outage.
Two-circuit switches can apply a different program to each circuit.
Mounting | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Knockout Trade Size | Wire Connection Type | Environment | Specifications Met | Each | |
24 Hour Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout, Day Skipper | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST, DPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout, Day Skipper | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper | |||||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 28 per Day | 1 min. | Push Button | SPST, DPST | 7 3/4" | 5" | 3" | No | 0.16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Switches with a day skipper can be programmed to skip operation for one to six days.
Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||
With Battery Backup, Lockout | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||
With Battery Backup, Lockout, Day Skipper | |||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper, Astronomical Timing | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPDT | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 000000 |