High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
20,000V DC/28,000V AC | ||||||||||||||
18 | 2 | 18/2 | 20 A @ 86° F | 0.24" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 20 A @ 86° F | 0.33" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 20 A @ 86° F | 0.43" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18 | 6 | 18/6 | 20 A @ 86° F | 0.62" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18 | 8 | 18/8 | 20 A @ 86° F | 0.81" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
18 | 10 | 18/10 | 20 A @ 86° F | 1" | 0.14" | 1.4" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 26 A @ 86° F | 0.26" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 26 A @ 86° F | 0.37" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 26 A @ 86° F | 0.48" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 6 | 16/6 | 26 A @ 86° F | 0.7" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 8 | 16/8 | 26 A @ 86° F | 0.92" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 0000 | 0000 | |
16 | 10 | 16/10 | 26 A @ 86° F | 1.14" | 0.15" | 1.5" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 0000 |
Ultra-High-Voltage Wire

- Use for panel and equipment (hook-up)
- Flexible
- Temperature Range: -40° to 300° F
- Insulation: Silicone Rubber
Use this wire in high-voltage applications, such as in high-power signs and lasers. It’s also known as corona-resistant hook-up wire. Made of silicone rubber, the insulation resists abrasion. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.