High-Current Time and Day Activated Switches
Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Environment | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 20 A @ 120 V AC, 208 V AC, 240 V AC, 277 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | SPDT | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 0000000 | __ | 000000 | 00 |
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | SPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | DPST | 7 3/4" | 5" | 3" | Screw Terminals | Indoor Only | 0000000 | 000000 | 1 | 0000000 | 0000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Outdoor High-Current Time and Day Activated Switches
Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
24-hour switches repeat the same program daily.
Switches with a day skipper can be programmed to skip operation for one to six days.
Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
Switches | Additional Trippers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Tripper Type | No. of Trippers | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Wire Connection Type | Each | Pkg. Qty. | Pkg. | ||
24-Hour Timing Cycle | |||||||||||||||||
1 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | SPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 0000000 | 1 | 0000000 | 00000 |
2 | 40 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 15 min. | Captive | 96 | Polycarbonate Plastic | DPDT | 8 7/8" | 6 5/8" | 3" | Screw Terminals | 0000000 | 000000 | __ | 000000 | 00 |
2 | 40 A @ 240 V AC | 120V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 12 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
24-Hour Timing Cycle with Day Skipper and Three Skip Screws | |||||||||||||||||
2 | 40 A @ 240 V AC | 120V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
2 | 40 A @ 240 V AC | 208V AC/240V AC/277V AC | 10 per Day | 1 hrs. | Removable | 2 | Steel | DPST | 9 3/8" | 5 1/2" | 3 5/8" | Screw Terminals | 0000000 | 000000 | 1 | 0000000 | 0000 |
Additional Day-Skip Screws (Pkg. of 3) | 0000000 | Pkg. | 00000 |
Time and Day Activated Switches
Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily.
Switches with trippers are programmed by setting on and off times by positioning trippers around the clock dial.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Ht. | Wd. | Dp. | Plug Type | Each | |
24-Hour Timing Cycle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 per Day | 30 min. | Trippers | Removable | 6 | 15 A @ 120 V AC | 1 | 3 1/4" | 3 1/4" | 3 1/4" | Three Prong | 0000000 | 000000 |
Outdoor Time and Day Activated Switches
Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Switches with light sensor control allow one device to be controlled by the presence or absence of light.
NEMA 3R rated switches are protected against falling liquids and light splashing.
Mounting | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Each | |
24-Hour Timing Cycle—NEMA 3R | |||||||||||||||||
12 per Day | 30 min. | Trippers | Removable | 4 | 15 A @ 120 V AC | 2 | Light Sensor Control | 9 3/8" | 5 1/2" | 3 3/8" | Three Prong | 2 | No | 4 | 1/4" | 0000000 | 0000000 |
Additional Trippers (Pkg. of 2 Pair) | 0000000 | Pkg. | 00000 |
Surface/DIN-Rail Mount Time and Day Activated Switches
Mount these switches to a flat surface or attach to DIN rail. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. These switches have a 24-hour timing cycle that repeats the same program daily. As UL and C-UL Recognized Components that are also CSA Certified and CE Marked, they meet American, Canadian, and European safety standards.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Each | |
24-Hour Timing Cycle | ||||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | SPDT | 4.2" | 2.8" | 2.2" | No | 3 | 0.13" | 35 | Screw Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
Panel-Mount Time and Day Activated Switches
Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards.
24-hour switches repeat the same program daily.
For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Specifications Met | Each | |
24-Hour Timing Cycle | ||||||||||||||||
1 | 21 A @ 250 V AC | 120V AC | 48 per Day | 15 min. | Trippers | Captive | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked | 0000000 | 000000 |
Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches
Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
Mounting | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | For DIN Rail Ht., mm | Ht. | Wd. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||||
2 | 15 A @ 250 V AC | 120V AC/240V AC | 12 per Day | 1 min. | Push Button | SPST-NO | 3.8" | 3.8" | 2.2" | No | 2 | 35 | 3.62" | 3.62" | Screw Terminals | 00000000 | 0000000 |
Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches
Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily.
Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||
With Battery Backup, Lockout | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 1/4" | 5" | 3" | No | 0.16" | Screw Terminals | 0000000 | 000000 |