McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    2 Products

    Sealed Large-Cell Batteries for Starting and Continuous Use

    Image of Product. Front orientation. Batteries. Sealed Large-Cell Batteries for Starting and Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Stud-Terminal Battery Connection.

    Stud-Terminal

    Battery

    Connection

    Image of Specification. Front orientation. D.

    D

    Deliver a surge of power to start automobiles and other vehicles, and provide power over a long time. These batteries are deep cycle, so they can handle many charge/deep discharge cycles. All are dry cell, so they have an absorbed glass mat (AGM) that soaks up the electrolyte and can be used in any position except upside down. They can be recharged hundreds of times.
    Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Battery
    Cap., A·h
    Battery Terminal
    Configuration
    Reserve
    Cap., min.
    Marine Cranking
    Amps
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    Dry-Cell AGM Lead Acid
     
    Stud-Terminal Battery Connection
    1231100D1901,0503/8"-16
    9.5"13"6.8"71805K420000000
     

    Large-Cell Batteries for Starting

    Image of Product. Front orientation. Batteries. Large-Cell Batteries for Starting.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Stud-Terminal Battery Connection.

    Stud-Terminal

    Battery

    Connection

    Image of Specification. Front orientation. D.

    D

    Deliver a surge of power to start automobiles and other vehicles. These wet-cell batteries contain electrolyte in an unsealed container, so they must be mounted upright. They may occasionally need to be filled with distilled water.
    Cold cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 0° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Battery Terminal
    Configuration
    Cold Cranking
    Amps
    Thread Size
    Ht.
    Wd.
    Dp.
    Each
    Wet Cell Lead Acid
     
    Stud-Terminal Battery Connection
    1231D9255/16"-18 (Negative Terminal), 3/8"-16 (Positive Terminal)9.4"13"6.8"7238K850000000
     
    back to top