    46 Products

    Threaded Air-Driven Diverting Valves

    Image of Product. Front orientation. Contains Annotated. Diverting Valves. Threaded Air-Driven Diverting Valves .
    Image of Attribute. Front orientation. Contains Annotated. Diverting Valves. Threaded Air-Driven Diverting Valves .
    To divert flow between ports more quickly than motor-driven valves, these operate on compressed air. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and wear. Valves are standard port, so they slightly restrict flow.
    Air-to-Divert/Air-to-Return—Air-to-divert/air-to-return valves require air pressure to divert flow to the right-port outlet and air pressure to return flow to the left-port outlet.
    Air-to-Divert/Spring Return—Air-to-divert/spring-return valves require air pressure to divert flow to the right-port outlet. They automatically return flow to the left-port outlet when the air turns off to ensure the valve only diverts flow to the right port when air is on.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Air
    Pipe
    Size
    Diverting Valve
    Flow Pattern
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Steam Pressure
    @ Temp.
    Pressure Range,
    psi
    Connection
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Electrical
    Connection
    Vacuum Rating,
    in. Hg
    For Use With
    Seal
    Material
    Certification
    Each
    Brass Body—NPT Female × NPT Female × NPT Female
     
    Single Acting: Air-to-Divert/Spring Return—120V AC
    1/4
    L-Pattern3.26400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 11/16"5 7/8"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T610000000
    3/8
    L-Pattern3.5400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 11/16"5 7/8"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T62000000
    1/2
    L-Pattern4.2400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 7/8"5 7/8"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T63000000
    3/4
    L-Pattern7400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3403 3/16"6"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T64000000
    1
    L-Pattern12.83400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3403 3/4"6 9/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T65000000
    1 1/2
    L-Pattern29.75400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3404 7/8"8 3/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T67000000
    2
    L-Pattern43.76400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3405 3/4"10 5/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T68000000
     
    Double Acting: Air-to-Divert/Air-to-Return—120V AC
    1/4
    L-Pattern3.26400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 11/16"4 3/4"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T21000000
    3/8
    L-Pattern3.5400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 11/16"4 3/4"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T22000000
    1/2
    L-Pattern4.2400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3402 7/8"4 3/4"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T23000000
    3/4
    L-Pattern7400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3403 3/16"4 15/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T24000000
    1
    L-Pattern12.83400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3403 3/4"6 9/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T25000000
    1 1/2
    L-Pattern29.75400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3404 7/8"7 3/4"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T27000000
    2
    L-Pattern43.76400 psi @ 175° F100 psi @ 340° F60 to 1251/4 NPT FemaleBall, Zero Pressure DropNone-4 to 3405 3/4"9 1/16"DIN B29Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, XenonPTFE
    C-UL Listed, UL Listed
    5883T28000000
     

    Air-Operated Air On/Off Valves

    Also known as blocking valves, these valves are activated by an air signal to turn equipment on and off. They allow airflow when an air signal is applied to the air pilot. When the air supply is removed, the valve closes, trapping air in the system.
    NPT Female Inlet × NPT Male Outlet × UNF Female Air Pilot
    Image of Product. Front orientation. Air-Actuated On/Off Valves. Air-Operated Air On/Off Valves.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Flow Rate @ 100
    psi, scfm
    Overall
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Air Pilot
    Thread Size
    For Air
    Pilot Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Lg.
    Wd.
    Ht.
    Each
    Brass Body
    1/8
    1/8
    10-32
    5/32"0.640151450 to 1601"1"2"62395K610000000
    1/4
    1/4
    10-32
    5/32"0.870201450 to 1601"1"2"62395K62000000
    3/8
    3/8
    10-32
    5/32"2.060451450 to 1601 3/8"1 1/8"2 3/16"62395K63000000
     
    Push to Connect Female Inlet × NPT Male Outlet × Push to Connect Female Air Pilot
    Image of Product. Front orientation. Air-Actuated On/Off Valves. Air-Operated Air On/Off Valves.
    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Flow Rate @ 100
    psi, scfm
    Overall
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    For Air
    Pilot Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Lg.
    Wd.
    Ht.
    Each
    Brass Body
    1/4"1/8
    5/32"0.640151450 to 1601 1/8"1"2"62395K650000000
    1/4"1/4
    5/32"0.870201450 to 1601 1/8"1"2"62395K66000000
     

    High-Flow Air-Driven On/Off Valves

    Also known as actuated ball valves, these provide higher flow rates than other air-driven valves. They operate on compressed air to automatically start and stop flow faster than motor-driven valves. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included).
    Direct Mount with Wire Leads—NEMA 4, IP66
    Image of Product. Front orientation. Contains Annotated. Air-Actuated On/Off Valves. High-Flow Air-Driven On/Off Valves, Direct Mount with Wire Leads—NEMA 4, IP66.
    Direct-mount actuators are directly attached to the valve body to minimize movement and reduce wear.
    NEMA 4 valves resist washdowns, splashing water, and dust.
    IP66 valves resist dust and high-pressure jets of water.
    Full Port—Full-port valves do not restrict flow.
    With Visual Flow Indicator—Valves with a visual flow indicator on the top of the actuator show whether the valve is open or closed.
    Single Acting—Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are fail closed unless actuated.
    Double Acting—Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
    Pressure Drop Assisted—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Replacement
    Air Actuators
    Replacement
    Valve Bodies
    Overall
    Air
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Steam
    Pressure @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Lg.
    Ht.
    Connection
    Pressure Range,
    psi
    Each
    Each
    Each
    Brass Body with Full Port and Visual Flow Indicator
     
    Single Acting: Air-to-Open, Spring Return (Fail Closed)—120V AC
    1/2
    FemaleNPT
    20600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3502 9/16"5 7/8"5 13/16"1/4 NPT Female80 to 1203672T4300000002872N1300000002873N11000000
    3/4
    FemaleNPT
    30600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3502 15/16"5 7/8"6 5/16"1/4 NPT Female80 to 1203672T440000002872N140000002873N1200000
    1
    FemaleNPT
    50600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3503 9/16"5 7/8"6 5/8"1/4 NPT Female80 to 1203672T450000002872N150000002873N1300000
    1 1/2
    FemaleNPT
    175600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3504 11/16"7 5/16"8 5/8"1/4 NPT Female80 to 1203672T470000002872N170000002873N15000000
    2
    FemaleNPT
    300600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3505 5/16"7 5/16"9 3/16"1/4 NPT Female80 to 1203672T480000002872N180000002873N16000000
     
    Double Acting: Air-to-Open, Air-to-Close—120V AC
    1/2
    FemaleNPT
    20600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3502 9/16"4 1/16"4 7/8"1/4 NPT Female80 to 1203672T33000000———02873N1100000
    3/4
    FemaleNPT
    30600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3502 15/16"4 1/16"5 5/16"1/4 NPT Female80 to 1203672T34000000———02873N1200000
    1
    FemaleNPT
    50600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3503 9/16"4 1/16"5 5/8"1/4 NPT Female80 to 1203672T350000002872N110000002873N1300000
    1 1/4
    FemaleNPT
    100600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3504 1/16"7 5/16"8 1/16"1/4 NPT Female80 to 1203672T360000002872N120000002873N14000000
    1 1/2
    FemaleNPT
    175600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3504 11/16"7 5/16"8 5/8"1/4 NPT Female80 to 1203672T37000000———02873N15000000
    2
    FemaleNPT
    300600 psi @ 100° FNot RatedBall, Pressure Drop Assisted0 to 3505 5/16"7 5/16"9 3/16"1/4 NPT Female80 to 1203672T38000000———02873N16000000
     
    Replacement Pilot Valves

    Made-to-Order Air-Operated Air-Exhaust Control Valves

    Image of Product. Front orientation. Air-Exhaust Valves. Made-to-Order Air-Operated Air-Exhaust Control Valves.
    When these valves receive an air signal, they quickly dump exhaust air to the atmosphere without routing it back through a directional control valve to speed up the movement of equipment. They're often used with air compressors that require continuous operation. A muffler reduces exhaust noise. Also known as quick exhaust valves.
    To Order: Specify minimum pressure and maximum pressure from the ranges listed. The difference between the minimum pressure and maximum pressure must be at least 10 psi, but no more than 30 psi.
    Overall
    No. of Flow
    Ports
    Inlet Pipe
    Size
    For Outlet
    Tube ID
    Air Pilot
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Body
    Material
    Lg.
    Wd.
    Ht.
    Lowest Avail.
    Pressure, psi
    Highest Avail.
    Pressure, psi
    Each
    Threaded Female Inlet × Barbed Male Outlet × Threaded Male Air Pilot
    4NPT, 1/8
    1/4"1/4 NPT20Not RatedBrass2 7/8"2 1/16"3 3/8"40 to 50240 to 2503206N11000000
     
    back to top