McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    System of Measurement
    Wire Construction
    Industrial Info Compare
    Shield Type
    Outer Jacket Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    49 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    Per
    Ft.
    600V AC
     
    SOOW Cable
    18/6
    5 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K1900000
    16/6
    8 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K370000
    14/6
    12 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 1007081K70000
    12/6
    16 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K690000
    10/6
    20 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K5900000
     

    Abrasion-Resistant Power Cable

    Image of Product. Front orientation. Power Cable. Abrasion-Resistant Power Cable, Unshielded.
    Image of Product. Front orientation. Power Cable. Abrasion-Resistant Power Cable, Shielded.

    Unshielded

    Shielded

    Pull this cable over rough surfaces without damage. The thick polyurethane jacket protects the wires inside and resists wear. It also stands up to moisture, oil, and chemicals.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    18/6
    6.3 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K15000000000000
     
    Shielded
    22/6
    2.7 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K19000000000
     

    Access Control Cable

    Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Access Control Cable.
    Outer
    Jacket
    Inner
    Insulation
    Security Cable
    Use
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Flammability Rating
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    300V AC/300V DC
    Card Reader
    Door Contact
    Exit Sign
    Lock
    22
    22
    22
    18
    6
    2
    4
    4
    22/6
    22/2
    22/4
    18/4
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    4 amp @ 86° F
    0.46"PVC
    YellowPVC
    Blue, Gray, Orange, White32 to 165CMP
    CSA C22.2 No. 0.3 FT65846N150000000000000000000000000000
     

    Twisted-Pair Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Twisted-Pair Continuous-Flex Control Cable.
    Prevent mixed messages in control systems such as sensors and PLCs. The twisted-pair wires in this cable prevent internal and external signal interference, even in electrically noisy areas. Designed for the demands of continuous motion, this cable transmits signals for millions of flex cycles. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Shielded
    24/6
    2.1"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    CE Marked
    ISO Class 1
    10, 25, 50, 1002099T130000000000
    24/6
    2.11"TPE
    Blue-30 to 210CE Marked
    ISO Class 1
    10, 25, 50, 1002099T3300000000
    22/6
    2.33"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    CE Marked
    ISO Class 1
    10, 25, 50, 1002099T62100000000
    20/6
    2.63"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    CE Marked
    ISO Class 1
    10, 25, 50, 1002099T2300000000
     

    Variable-Frequency Drive Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power and Control Wire—Stranded with Polyethylene Outer Jacket
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. Variable-Frequency Drive Motor Cable. Power and Control Wire—Stranded with Polyethylene Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power and control wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    Power
    Wire
    Control
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    416
    16/4
    218
    18/2
    18 amp @ 86° F0.57"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T116000000000000000000000000000000000
    414
    14/4
    218
    18/2
    25 amp @ 86° F0.62"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T1200000000000000000000000000000
    412
    12/4
    218
    18/2
    30 amp @ 86° F0.65"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T1400000000000000000000000000000
     

    Riser-Rated Communication and Security System Cable

    This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    622/6
    0.16"PVC
    GrayPVC
    Black, Blue, Brown, Green, Red, White0 to 140CMR, CL3R
    ETL Listed, C-ETL Listed
    8280T330000000000000000000000000000000
    18
    618/6
    0.21"PVC
    GrayPVC
    Black, Blue, Brown, Green, Red, White0 to 140CMR, CL3R
    ETL Listed, C-ETL Listed
    8280T3900000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Riser-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    18
    618/6
    0.23"PVC
    GrayPVC
    Black, Blue, Brown, Green, Red, White0 to 140Uninsulated Ground WireCMR, CL3R
    ETL Listed, C-ETL Listed
    8233T3700000000000000000000000000000000
     

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    24/6
    5 amp @ 86° F1.8"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2505106N130000000000
     

    Wall Telephone Cords

    Image of Product. Front orientation. Telephone Cords. Wall Telephone Cords, Plug.

    Plug

    RJ12 Connection/RJ25 Connection—RJ12/RJ25 plugs are designed for multiline telephone networks and data networks.
    Lg.,
    ft.
    AWG
    No. of
    Wires
    Connection
    End Type
    Gender
    Color
    Each
    RJ12 Connection/RJ25 Connection
    732
    6PlugMaleSilver5703T3600000
    1432
    6PlugMaleSilver5703T7110000
    2532
    6PlugMaleSilver5703T4110000
     

    High-Voltage Continuous-Flex Flat Power Cable

    Image of Product. Front orientation. Power Cable. High-Voltage Continuous-Flex Flat Power Cable.
    For high-voltage systems with constant motion, this cable flexes without breaking. Its thick silicone rubber jacket insulates against high voltage and resists chemicals, oil, moisture, and UV rays. The jacket also has a low-smoke, zero-halogen (LSZH) design to prevent toxic emissions if there’s a fire.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room Std.
    Choose a Length, ft.
    1-99
    100-Up
    17,000V AC/12,000V DC
     
    Unshielded
    28/6
    5 amp @ 86° F0.8"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T1040000000000
    26/6
    6 amp @ 86° F0.9"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T20400000000
    24/6
    8 amp @ 86° F1"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T30400000000
     
    25,000V AC/18,000V DC
     
    Unshielded
    22/6
    11 amp @ 86° F1.1"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T40400000000
    20/6
    13 amp @ 86° F1.2"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T50400000000
     
    28,000V AC/20,000V DC
     
    Unshielded
    18/6
    20 amp @ 86° F1.4"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T60400000000
    16/6
    26 amp @ 86° F1.5"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10, 20, 30, 50, 1009634T7040000000000
     

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    622/6
    0.16"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T130000000000000000000000000000000
    18
    618/6
    0.21"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1900000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    18
    618/6
    0.23"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1700000000000000000000000000000000
     

    Low-Capacitance Control Cable

    Image of Product. Front orientation. Control Cable. Low-Capacitance Control Cable.
    This cable protects signal integrity over long runs, even up to hundreds of feet across your facility. It has polyethylene insulation to limit capacitance—an energy buildup that worsens over long distances and degrades signals. This cable is often used in sensors, PLCs, and encoders. You can flex and bend it during installation and adjustments, but it isn't made for continuous motion.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Transmission
    Speed, Mbit/s
    Capacitance
    per ft., pF
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Double Shielded
    24/6
    1012.5PVC
    GrayCM
    0 to 165UL 2556 VW-1
    10, 25, 50, 100, 50075985K630000000000
     

    Communication and Security System Cable

    Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Choose a Length, ft.
    1-99
    100-Up
    300V AC/300V DC
    24
    624/6
    0.21"PVC
    GrayPVC
    Black, Blue, Brown, Green, Red, White0 to 175Uninsulated Ground WireCM, CMG
    10, 25, 50, 100, 200, 50075985K520000000000
     

    Miniature Continuous-Flex Control Cable

    Image of ProductInUse. Front orientation. Control Cable. Miniature Continuous-Flex Control Cable.
    Image of Product. Front orientation. Control Cable. Miniature Continuous-Flex Control Cable.
    Deliver precise signals through compact areas. This cable is ideal for continuous motion in small, automated equipment, such as the micro gantry in a 3D printer. It will last for millions of flex cycles while reliably transmitting signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    10 ft.
    Long
    25 ft.
    Long
    200V AC
     
    Shielded
    26/6
    2.4 amp @ 86° FPVC
    Black-40 to 2203890N3100000000000000
     

    Irrigation Cable

    Image of Product. Front orientation. Irrigation Cable.
    This wire is often used for sprinkler systems.
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation Color
    Temp. Range,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    Solid Wire with Polyethylene Outer Jacket
     
    30V AC/30V DC
    18
    618/6
    0.27"BlackPolypropylene
    Blue, Brown, Green, Red, White, Yellow0 to 140UL Listed
    8070T1500000000000000000000000000000000000000
     

    Thermostat Cable

    Image of Product. Front orientation. Thermostat Cable.
    Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Solid Wire
     
    150V AC/150V DC
    20
    620/6
    0.16"PVC
    BrownPolyethyleneBlue, Brown, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T150000000000000000000000000000000
    18
    618/6
    0.19"PVC
    BrownPolyethyleneBlue, Brown, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T2500000000000000000000000000
     

    Coiled Power Cable

    Image of Product. Front orientation. Power Cable. Coiled Power Cable.
    Extend to full length for added reach, then watch this cable retract and self-coil for convenience. It's often used with hand tools, pendant switches, and other portable devices.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    Extends from 6
    ft. to 30 ft. Long
    Extends from 8
    ft. to 40 ft. Long
    300V AC
     
    SJEOW Cable
    16/6
    7 amp @ 86° FTPE
    Black0 to 175C-UL Listed, UL Listed
    7520K210000000000000000000000000000
     
    600V AC
     
    SEOW Cable
    16/6
    7 amp @ 86° FTPE
    Black0 to 175C-UL Listed, UL Listed
    7520K25000000000000000000000000
     
    SOW Cable
    16/6
    8 amp @ 86° FNeoprene
    Black-40 to 190CSA Certified, UL Listed
    7088K221000000000000
     

    Twisted-Pair Low-Capacitance Control Cable

    Image of Product. Front orientation. Control Cable. Twisted-Pair Low-Capacitance Control Cable.
    A dynamic duo inside this cable protects signal integrity over long distances, even up to hundreds of feet across your facility. Twisted-pair conductors block internal and external signal interference. Plus, polyethylene insulation limits capacitance, preventing the energy buildup that degrades signals over long runs. This cable is often used with equipment such as sensors and PLCs. You can flex and bend it during installation and adjustments, but it’s not made for continuous motion.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Transmission
    Speed, Mbit/s
    Capacitance
    per ft., pF
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Double Shielded
    24/6
    1012.5PVC
    GrayCM, CMG
    0 to 16510, 25, 50, 100, 50075985K730000000000
     

    Coiled Control Cable

    Image of Product. Front orientation. Control Cable. Coiled Control Cable, Unshielded.

    Unshielded

    This cable gives you room to roam. It extends as you move, then retracts and self-coils for convenience. It's often used with low-current communication equipment such as microphones and headsets.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    300V AC
     
    Unshielded
    23/6
    1 amp @ 86° FNeoprene
    Black-40 to 140UL Listed
    69115K140000000000000
     

    Telephone Cable

    Image of Product. Front orientation. Telephone Cable. Telephone-to-Wall Jack.

    Telephone-to-Wall Jack

    Connect telephones and telephone blocks to a wall jack. Terminate the cable with telephone plugs or jacks (not included).
    For RJ
    No.
    AWG
    No. of
    Wires
    Cable
    AWG
    Lg.,
    ft.
    Outer Jacket
    Color
    Each
    Stranded Wire
     
    Telephone-to-Wall Jack
    RJ12, RJ2528
    628/6
    50Gray5703T34000000
    RJ12, RJ2528
    628/6
    500Gray5703T91100000
     

    Circuit Board Cable

    Made of thin, flattened wires, this flexible cable can be routed in tight spaces, such as inside a laptop. Connect it to your circuit board with circuit board connectors (not included).
    Same-Side Contact Location
    Image of Product. Front. Front orientation. Circuit Board Cable. Same-Side Contact Location.
    Image of Product. Front orientation. Circuit Board Cable. Same-Side Contact Location.

    Front

    Image of Product. Back. Back orientation. Circuit Board Cable. Same-Side Contact Location.

    Back

    Contact
    6" Long
    12" Long
    No. of
    Wires
    Current @ Temp.
    Wd.
    Thk.
    Lg.
    Ctr.-to-Ctr.,
    mm
    Outer Jacket
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Pkg.
    Qty.
    Pkg.
    Pkg.
    Solid Wire
     
    60V AC
    61.25 amp @ 86° F0.28"0.01"0.16"1White-40 to 220UL 2556 VW-1
    57452N15000007452N17000000
     
    Opposite-Side Contact Location
    Image of Product. Front. Front orientation. Circuit Board Cable. Opposite-Side Contact Location.
    Image of Product. Front orientation. Circuit Board Cable. Opposite-Side Contact Location.

    Front

    Image of Product. Back. Back orientation. Circuit Board Cable. Opposite-Side Contact Location.

    Back

    Contact
    6" Long
    12" Long
    No. of
    Wires
    Current @ Temp.
    Wd.
    Thk.
    Lg.
    Ctr.-to-Ctr.,
    mm
    Outer Jacket
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Pkg.
    Qty.
    Pkg.
    Pkg.
    Solid Wire
     
    60V AC
    61.25 amp @ 86° F0.28"0.01"0.16"1White-40 to 220UL 2556 VW-1
    57452N16000007452N18000000
     