McMaster-Carr logo
    Filter by
    Conduit Trade Size
    Industrial Info Compare
    Thread Type
    Industrial Info Compare
    Fitting Connection
    Conduit Type
    Industrial Info Compare
    Conduit Connection
    For Conduit Flexibility
    Flexibility
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Connects To
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Hazardous Location Protection Type
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    33 Products
    About Conduit
    industrial info icon

    Compare rigid and flexible conduit materials and identify the trade size for compatible fittings.

    Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings

    Image of System. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings.
    The industry standards, IMC and RMC conduit systems offer the most durable protection indoors, outdoors, and underground. Both types have the same outside diameter, so they use many of the same fittings. This interchangeability makes retrofits easier and reduces the parts you need to keep on hand.
    Conduit Bushings
    Image of Product. Threaded Connection. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings, Straight, Bushing Fitting, Threaded Conduit Connection.

    Threaded

    Connection

    Threaded internally and externally to connect two different-sized pieces of conduit.
    Zinc-Plated Steel—The strength of steel with a plating that protects from occasional exposure to moisture.
    Aluminum—One-third the weight of steel that's the same size. Aluminum is also nonmagnetic to prevent electrical interference in nearby equipment.
    Conduit Connection
    Conduit Trade
    Size
    Thread
    Type
    Gender
    For Conduit
    Type
    Specs.
    Met
    Each
    Threaded Conduit Connection
     
    Zinc-Plated Steel
    3/4 × 1/2NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K3100000
    1 × 1/2NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K320000
    1 × 3/4NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K330000
    1 1/4 × 1/2NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K340000
    1 1/4 × 3/4NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K350000
    1 1/4 × 1NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K360000
    1 1/2 × 1NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K430000
    2 × 1/2NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K3700000
    2 × 3/4NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K3800000
    2 × 1NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K3900000
    2 × 1 1/4NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K4100000
    2 × 1 1/2NPSMMale × FemaleIMC, RMC
    UL Listed
    7514K4200000
     
    Aluminum
    3/4 × 1/2NPTMale × FemaleRMC
    UL Listed
    7864T210000
    1 × 1/2NPTMale × FemaleRMC
    UL Listed
    7864T220000
    1 × 3/4NPTMale × FemaleRMC
    UL Listed
    7864T230000
    1 1/4 × 1/2NPTMale × FemaleRMC
    UL Listed
    7864T240000
    1 1/4 × 3/4NPTMale × FemaleRMC
    UL Listed
    7864T250000
    1 1/4 × 1NPTMale × FemaleRMC
    UL Listed
    7864T260000
    1 1/2 × 3/4NPTMale × FemaleRMC
    UL Listed
    7864T2700000
    1 1/2 × 1NPTMale × FemaleRMC
    UL Listed
    7864T2800000
    2 × 3/4NPTMale × FemaleRMC
    UL Listed
    7864T2900000
    2 × 1NPTMale × FemaleRMC
    UL Listed
    7864T3100000
    2 × 1 1/4NPTMale × FemaleRMC
    UL Listed
    7864T3200000
    2 × 1 1/2NPTMale × FemaleRMC
    UL Listed
    7864T3300000
     
    Hazardous Location Conduit Bushings
    Image of Product. Threaded Connection. Front orientation. Conduit and Fittings. Medium-Wall (IMC) and Thick-Wall (RMC) Metal Conduit and Fittings, Bushing Fitting, Straight, Hazardous Locations, Threaded Conduit Connection.

    Threaded

    Connection

    Join different sizes of threaded conduit in areas where gas, dust, and fibers could cause a fire or explosion if they entered the system.
    Aluminum—One-third the weight of steel that's the same size. Aluminum is also nonmagnetic to prevent electrical interference in nearby equipment.
    Conduit Connection
    Conduit Trade
    Size
    Thread
    Type
    Gender
    For Conduit
    Type
    Hazardous Location Rating
    Specs. Met
    Each
    Threaded Conduit Connection
     
    Aluminum
    3/4 × 1/2NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4100000
    1 × 1/2NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T420000
    1 × 3/4NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T430000
    1 1/4 × 1/2NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4400000
    1 1/4 × 3/4NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4500000
    1 1/4 × 1NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4600000
    1 1/2 × 1NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4700000
    2 × 1NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4800000
    2 × 1 1/2NPTMale × FemaleRMC
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIC, IIB, IIA
    CSA Certified, UL Listed7862T4900000
     
    back to top