System of Measurement System of Measurement |
---|
|
Connection Type Connection Type | Show |
---|
|
Connection Type Connection Type | Hide |
---|
Cord Insulation Material Cord Insulation Material |
---|
|
Specifications Met Specifications Met |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Industry Designation for Cable Insulation
More
Power Cords





Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
SVT cords are ultra-flexible and as pliable as vacuum cleaner cords. They withstand repeated winding.
SJEOW cords have an oil- and water-resistant insulation.
The insulation on SJTW cords resists water.
Use SJT cords in dry or damp locations.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 6 | 0.32" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 00000 |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 0000 |
18 | 10 | 125V AC | 9 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 00000 |
18 | 10 | 125V AC | 9 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 3 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
16 | 13 | 125V AC | 6 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
16 | 13 | 125V AC | 6 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.37" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000000 | 0000 |
14 | 15 | 125V AC | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.37" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 0000 |
16 | 13 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
Light Duty Power Cords






Designed for indoor applications, these cords are often used to power appliances.
SPT cords have a flat cord shape so they fit in tight spaces. The numbers 1, 2, and 3 indicate the relative thickness of the insulation. SPT-3 is the thickest, so it is less flexible but more durable than -1 and -2 cords.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 6 | __ | 0.19" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
18 | 10 | 125V AC | 6 | __ | 0.25" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.25" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 9 | __ | 0.19" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 125V AC | 6 | __ | 0.31" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 6 | __ | 0.31" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 6 | __ | 0.38" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.31" | PVC Plastic | SPT-1 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.31" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 0000 |
18 | 10 | 125V AC | 8 | __ | 0.38" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
18 | 10 | 125V AC | 9 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 6 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
16 | 13 | 125V AC | 6 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 8 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
16 | 13 | 125V AC | 8 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 1/2 | 0.38" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
IEC C14 Plug × Wire Leads | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.33" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
Coiled Power Cords


These self-coiling cords stretch to full length and then return to their retracted length for tangle-free storage. The industry designation is SJEOW, so the insulation resists oil and water.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Retracted Lg., ft. | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 7 | 125V AC | 1 | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
Sure-Grip Power Cords


Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
16 | 13 | 125V AC | 12 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 00000 |
International Power Cords





All cords have a country-specific plug to power equipment on international outlets.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Country Compatibility | International End Style | Metric Wire Size, mm2 | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Temp. Range, °F | Specifications Met | Color | Each | |
Plug × Wire Leads | ||||||||||||
Australia | AS 3112 | 1 | 10 | 250V AC | 8 | 0.28" | PVC Plastic | 35° to 150° | ASA Approved | Black | 0000000 | 000000 |
France Germany Italy Spain Switzerland | CEE 7/7 | 1 | 10 | 250V AC | 8 | 0.28" | PVC Plastic | -10° to 140° | CE Marked, IEC 60320 | Black | 0000000 | 00000 |
90° Elbow Plug × Wire Leads | ||||||||||||
Hong Kong Ireland United Kingdom | BS 1363 | 1 | 10 | 250V AC | 8 | 0.28" | PVC Plastic | -10° to 140° | CE Marked, IEC 60320 | Black | 0000000 | 00000 |
Safety Start-Up Power Cords



After shutting off power to equipment during a power failure, these cords must be manually reset, preventing unexpected equipment start-up. Use them to replace three-wire power cords on equipment driven by small single-phase motors. The industry designation is SJTO, so the insulation resists oil.
Wire Gauge | Current, A | Voltage | Lg., ft. | Cord OD | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
Wire Leads × Wire Leads | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
14 | 15 | 250V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 0000000 |
14 | 18 | 125V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 000000 |
NEMA 5-15 Plug × Wire Leads | ||||||||||
14 | 15 | 125V AC | 8 × 1 1/2 | 0.38" | SJTO | 32° to 165° | UL Recognized Component, C-UL Recognized Component | Black | 0000000 | 000000 |
Equipment-Cooling Fan Power Cords





Plug these cords into fans that have quick-disconnect terminals. The industry designation is SPT, so they have a flat cord shape.
Cords with a 90° elbow socket fit flush against the fan, so they fit in tight spaces.
Cords with a 45° elbow socket fit close against the fan.
Those with a temperature switch turn a fan on when the temperature reaches 88° F and off when it falls to 80° F. They are not adjustable.
No. of Outlets | Socket End Shape | Voltage | Features | Lg., ft. | Cord Wd. | Industry Designation | Specifications Met | Color | Each | |
Wire Leads × Fan Socket | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Straight | 125V AC | __ | 2 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 00000 |
1 | Straight | 125V AC | __ | 3 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 0000 |
1 | 45° Elbow | 125V AC | __ | 2 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 0000 |
1 | 45° Elbow | 125V AC | __ | 3 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 0000 |
1 | 45° Elbow | 125V AC | Temperature Switch | 2 | 0.2" | SPT-1 | UL Listed, CSA Certified | Green | 000000000 | 00000 |
1 | 45° Elbow | 125V AC | Temperature Switch | 3 | 0.2" | SPT-1 | UL Listed, CSA Certified | Green | 000000000 | 00000 |
1 | 90° Elbow | 125V AC | __ | 2 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 0000 |
1 | 90° Elbow | 125V AC | __ | 3 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 00000000 | 0000 |
2 | 45° Elbow | 125V AC | __ | 6 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 000000000 | 0000 |
3 | 45° Elbow | 125V AC | __ | 6 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 000000000 | 0000 |
4 | 45° Elbow | 125V AC | __ | 6 | 0.2" | SPT-1 | UL Listed, CSA Certified | Black | 000000000 | 0000 |
Distribution Blocks for Nano M8 and Micro M12 Cords




Connect multiple devices to these distribution blocks to create a network between equipment. They’re rated IP67 for protection from dust and submersion and IP65 for protection from low-pressure washdown.
Socket | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal Output Type | Housing Thread Size | No. of Outlets | No. of Poles | No. of Keyways | Coding | Face Dia. | Cord Lg., ft. | Current, A | Voltage | Wire Gauge | Cord OD | Environmental Rating | Specifications Met | Temp. Range, °F | Color | Each | |
Socket (Internal Thread) with Wire Leads | |||||||||||||||||
PNP | M8 | 4 | 3 | 0 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 0000000 |
PNP | M8 | 4 | 3 | 0 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | 0 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | 0 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | 1 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | 1 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | 1 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | 1 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
Turn-Lock Power Cords







The plug on these cords turns to lock in an outlet, so they remain securely attached in high-vibration applications.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA Plug × Wire Leads | ||||||||||||
L5-15 | 14 | 15 | 125V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 000000 |
L5-20 | 12 | 20 | 125V AC | 8 | 0.44" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L5-30 | 10 | 30 | 125V AC | 8 | 0.56" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-15 | 14 | 15 | 250V AC | 8 | 0.38" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-20 | 12 | 20 | 250V AC | 8 | 0.44" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
L6-30 | 10 | 30 | 250V AC | 8 | 0.56" | PVC Plastic | SJT | 0° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
Tablet Holders with Emergency Stop Push-Button Switch




Halt machinery in an instant with these tablet holders. They equip your tablet with safety switches that meet IEC and EN standards, so you can safely move around your equipment while teaching robots or monitoring production lines and conveyor systems.
The emergency stop switch on the front of the holder illuminates when the switch is enabled. There is also a deadman switch on the back of the holder that controls machinery when you lightly press and hold it in the middle position. If the switch is released or pressed down all the way, it stops the machine.
Pivot the handle to hold a tablet vertically or horizontally, while keeping the switches in a comfortable position for either hand. The adjustable mounting bracket secures a variety of tablet sizes. Connect your tablet to the USB port to charge during use.
Bracket adjustment kits enlarge the bracket to hold tablets with thick covers and protectors.
For technical drawings and 3-D models, click on a part number.