McMaster-Carr logo
    Filter by
    Display Type
    Resettable
    Number of Digits
    Counting Direction
    System of Measurement
    Electrical Connection Type
    Panel Cutout Width
    Enclosure Rating
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    56 Products

    Counters with Proximity Sensor

    Image of Product. Front orientation. Counters. Counters with Proximity Sensor .
    Count metallic objects as they touch or pass within 0.059" of this counter's built-in sensor. It has an output relay to send a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. A scaling function lets you adjust the unit of measure to suit your application. Counter and enclosure are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Drill through the back of the enclosure to mount to a wall or work surface.
    Sensor
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts
    per min.
    Max. Sensing
    Distance
    Lg.
    Dia.
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Operating
    Voltage, V AC
    Output Relay Current @ Input Voltage
    Features
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
    YesDown, Up62300,0000.059"3 1/2"3/4"107.5"7.5"5.1"85 to 2505 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    Scaling FunctionNEMA 4X
    UL Listed, C-UL Listed
    Plastic18875T71000000000
     

    Combination Switch-Contact/Electrically Actuated Counters with Output Relay

    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters with Output Relay , Style A.

    Style A

    You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. An output relay sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm. If power is lost, count backup maintains the count and programming backup maintains settings.
    Password Lockout—Password lockout prevents tampering and accidental loss of data.
    Scaling Function—A scaling function lets you adjust the unit of measure to suit your application.
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts per Min.
    (Input Method)
    Overall
    Dp.
    Input Voltage,
    V DC
    Operating
    Voltage
    Output Relay Current
    @ Input Voltage
    Includes
    Features
    Enclosure
    Rating
    Certification
    Each
    Style A—For 1/8 DIN Panel Cutout (1.77" Ht. × 3.62" Wd.)
     
    Screw On
    YesDown, Up621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V ACCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T420000000
    YesDown, Up621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T43000000
    YesUp and Down621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T39000000
     

    Large-Display Combination Switch-Contact/Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Large-Display Combination Switch-Contact/Electrically Actuated Counters .
    The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Counters can be wired for remote reset. They are protected against dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
    Overall
    Mounting
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min.
    (Input Method)
    Digit
    Ht.
    Ht.
    Wd.
    Dp.
    Input Voltage
    Operating Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
     
    Screw Terminals
    YesDown, Up41,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"12"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T410000000
    YesDown, Up41,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"20"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T42000000
    YesDown, Up61,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"16"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T43000000
    YesDown, Up61,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"26"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T4400000000
     

    Counters/Ratemeters

    Image of Product. Front orientation. Counters. Counters/Ratemeters , Clip On.

    Clip On

    Wire these counters/ratemeters to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. A scaling function lets you adjust the unit of measure to suit your application. Use the toggle button to switch between the count and the rate. IP or NEMA rated, they protect against dust and washdowns and can be used outdoors.
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Input Voltage
    Features
    Enclosure
    Rating
    Certification
    Each
    Clip On
     
    Screw Terminals
    YesUp and Down8960,000 (Voltage), 3,000 (Switch Contact)1.29"2.62"1.54"2.95"1.86"1.25V DC to 28V DC (High Level), 2.75V DC to 28V DC (Low Level)Quadrature Sensing, Scaling Function, Toggle ButtonNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    4126K410000000
     

    DIN-Panel-Mount Counters/Ratemeters

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Counters/Ratemeters .
    For quick installation, these counters/ratemeters fit a standard 1/8 DIN panel cutout. Wire them up to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. The scaling function lets you adjust the unit of measure to suit your application. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X).
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Input Voltage,
    V DC
    Operating
    Voltage
    Includes
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3085V AC to 250V AC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    2620T510000000
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3011V DC to 36V DC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    2620T52000000
     
    Output Relays

    Combination Switch-Contact/Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters , Screw On, Style B.

    Screw On

    Style B

    You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Count backup maintains the count if power is lost.
    Password Lockout—Password lockout prevents tampering and accidental loss of data.
    Programming Backup—Counters with programming backup maintain settings if power is lost.
    Scaling Function—A scaling function lets you adjust the unit of measure to suit your application.
    For Panel
    Cutout
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min.
    (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Overall
    Dp.
    Input Voltage
    Operating
    Voltage, V AC
    Includes
    Features
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC120Count Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T330000000
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC12012V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T41000000
     

    Large-Display Combination Switch-Contact/Electrically Actuated Counters with Output Relay

    Image of Product. Front orientation. Counters. Large-Display Combination Switch-Contact/Electrically Actuated Counters with Output Relay .
    The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. They can be wired for remote reset. An output relay sends a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts per Min.
    (Input Method)
    Digit
    Ht.
    Ht.
    Wd.
    Dp.
    Input Voltage,
    V DC
    Operating Voltage
    Output Relay Current @ Input Voltage
    Mounting
    Screw Size
    Enclosure
    Rating
    Each
    Screw On
     
    Screw Terminals
    YesDown, Up611,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"16"2.25"2.75 to 2821.6V DC to 250V DC
    50V AC to 250V AC
    5 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    No. 10
    NEMA 4X
    16635T810000000
    YesDown, Up611,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"26"2.25"2.75 to 2821.6V DC to 250V DC
    50V AC to 250V AC
    5 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    No. 10
    NEMA 4X
    16635T8300000000
     

    Large-Display Counters/Ratemeters with Output Relay

    Image of Product. Front orientation. Counters. Large-Display Counters/Ratemeters with Output Relay .
    At a glance, quickly read counts and rates in units, such as gallons per minute. The display on these counters/ratemeters is visible up to 130 ft. away—almost half of a football field—and gets brighter or dimmer based on your lighting. They have an output relay, so you can program them to start or stop a process or trigger an alarm when they reach their setpoint. These counters/ratemeters count using either a voltage or switch contact input, so they work with most sensors, encoders, and switches. You can wire them to reset remotely.
    Press the button on the display to toggle between the count and rate. You can also program these counters/ratemeters to toggle automatically between the count and rate every few seconds. With the scaling function, you can change the unit of measure. Hardwire them to power the display. They have a programming backup, so if you lose power you won't lose your settings.
    IP65 and NEMA 4X rated, these counters/ratemeters stand up to dust, rain, snow, and washdowns.
    Overall
    Mounting
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    Ht.
    Wd.
    Dp.
    Input
    Voltage
    Output Relay Current
    @ Input Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
     
    Screw Terminals
    YesUp and Down61,500,000 (Voltage), 1,500,000 (Switch Contact)4"16"2.25"28V DC5 amp @ 120V AC
    5 amp @ 28V DC
    Programming Backup, Scaling Function, Toggle ButtonNoNo. 10
    NEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    7381N12000000000
    YesUp and Down61,500,000 (Voltage), 1,500,000 (Switch Contact)7.875"26"2.25"28V DC5 amp @ 120V AC
    5 amp @ 28V DC
    Programming Backup, Scaling Function, Toggle ButtonNoNo. 10
    NEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    7381N1100000000
     

    Contactless Flow Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Contactless Flow Transmitters.
    Using ultrasonic waves, these transmitters measure the flow rate of your liquid from outside your pipe. They're a good choice for applications where you need to retrofit your system or avoid liquid coming into contact with the transmitter. Also known as transducers, these transmitters convert measurements to an electrical pulse that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). The pulse outputs match the input voltage of the transmitter. The higher the flow, the more pulses they send. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Configure them for either a 4-20mA or digital pulse output when installing.
    A digital display makes it easy to check flow rate and configure settings. Clamp these transmitters onto your pipe with the included mounting hardware and gel pads. They measure flow no matter the mounting orientation.
    These transmitters are calibrated with water but can be used with other liquids and will generally measure accurately, even if they differ in viscosity and density. You can recalibrate them in the field for accurate readings on pipe and operating conditions.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Range for
    Pipe Size, gpm
    Input
    Voltage
    Flow Measurement
    Type
    For Pipe
    Size
    3/4
    2
    4
    End-to-End
    Lg.
    Accuracy
    Temp. Range,
    ° F
    Min.,
    V DC
    Max.
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Pulse Output and One 4-20 mA Analog Transmitter Output—Wire Lead Connection
     
    Polycarbonate Body
    Ultrasonic3/4 to 40 to 450 to 3200 to 1,2859 3/4"±3%32 to 1851224V AC/24V DCAny AngleYesIP54
    4399N11000000000
     

    Flow Transmitters with Sight

    Image of Product. Front orientation. Flow Transmitters. Flow Transmitters with Sight.
    Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Digital Pulse Output—Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One Digital Pulse Output—Wire Lead Connection
     
    Polypropylene Body with Polypropylene Fitting
    Turbine1/4 NPT Female0.1 to 53 1/16"±7%100 psi @ 70° F33 to 180Fluoroelastomer
    4.25 to 24Any AngleNo15 to 2259687K110000000
    Turbine1/2 NPT Female1.5 to 203 1/16"±15%100 psi @ 70° F33 to 180Fluoroelastomer
    4.25 to 24Any AngleNo15 to 2259687K12000000
     
    Brass Body with Brass Fitting
    Turbine1/4 NPT Female0.1 to 53"±7%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K21000000
    Turbine1/2 NPT Female1.5 to 203"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K22000000
    Turbine1 NPT Female8 to 603 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K24000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine1/2 NPT Female1.5 to 203"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K32000000
    Turbine3/4 NPT Female5 to 303 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K33000000
    Turbine1 NPT Female8 to 603 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K34000000
     

    Electrically Actuated Minute Meters

    Image of Product. Front orientation. Hour Meters. Electrically Actuated Minute Meters, Screw On, Style B.

    Screw On

    Style B

    Display running time on a machine so you can schedule preventative maintenance.
    For Panel
    Cutout
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Operating
    Voltage
    Certification
    Each
    Screw On
     
    Wire Lead Connection
    BYesUp52.3"2.3"3"3"3"120V ACUL Listed
    1693T570000000
     

    Panel-Mount Electrically Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style B.

    Screw On

    Style B

    Display running time on a machine so you can schedule preventative maintenance.
    Not Resettable—Non-resettable meters prevent tampering and accidental loss of data.
    For Panel
    Cutout
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Dia.
    Wd.
    Ht.
    Dp.
    Dia.
    Operating
    Voltage
    Each
    Screw On
     
    Wire Leads
    BNoUp62.3"2.3"2.5"3"120V AC1693T840000000
    BNoUp62.3"2.5"3.5"120V AC1693T2600000
     

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Displays
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Displays.
    Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
    Displays
    Brackets
    Temp.,
    ° F
    For Panel
    Cutout, mm
    Mounting Slot
    Maximum Total
    Volume Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    For DIN Panel
    Cutout Size
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Lg.
    Wd.
    No.
    of
    Each
    9,999 Gallons
    9,999 Liters
    ±0.5%180 psi @ 70° F331491/4969641YesIP65
    NEMA 4X
    4114K33500000003/16"3/4"44114K94000000
     

    Insertion-Mount Flow and Temperature Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Image of Product. Top orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Thread mounting hardware (sold separately) into your pipe connection and insert the probe of these transmitters to measure the flow and temperature of water, oil, or air. The probe is held in place with a compression fitting on the other end of the mounting hardware. They’re often used in large-diameter pipes where it would be difficult to install a transmitter inline. To calculate the flow rate, these transmitters generate a small amount of heat, then measure the cooling effect your liquid or air has on it. They measure and output both flow and temperature, making them ideal for applications where temperature fluctuates. Also known as transducers, they convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. They’ll measure flow correctly in any mounting orientation. These transmitters are calibrated with air, glycol solutions, oil, and water but can be recalibrated in the field for other liquids.
    Adjust settings at the source using the digital display. These transmitters have two configurable outputs. One can be wired for flow or temperature as an analog output or a digital switch. The other one can be wired for flow as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. To change settings and receive error messages remotely from your PLC or computer, you can program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Measurement
    Type
    Flow Range,
    gpm
    Probe
    Lg.
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting
    Thermal0.02 to 123 15/16"7 9/16"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N1010000000
    Thermal0.02 to 127 7/8"11 1/2"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N102000000
     
    Flow Transmitter Mounting Hardware

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction1/2 NPT Female0.03 to 6.60.1 to 252 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N1010000000
    Magnetic Induction3/4 NPT Female0.02 to 13.220.2 to 502 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N102000000
    Magnetic Induction1 NPT Female0.1 to 26.40.2 to 1002 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N103000000
    Magnetic Induction1 1/2 NPT Female1.3 to 79.35 to 3006 11/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10400000000
    Magnetic Induction2 NPT Female1.3 to 158.55 to 6007 1/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10500000000
     

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Variable Area Flow Measurement.

    Variable Area Flow

    Measurement

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Vortex Flow Measurement.

    Vortex Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Variable Area Flow Measurement—Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
    Vortex Flow Measurement—Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Variable Area3/4 NPT Female5 to 2405 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N110000000
    Variable Area3/4 NPT Female7 to 3605 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N12000000
    Variable Area3/4 NPT Female10 to 6005 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N13000000
    Variable Area1 NPT Female30 to 1,6205 3/4"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N14000000
    Variable Area1 1/2 NPT Female60 to 3,0006 3/16"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N15000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Vortex1/2 NPT Female16 to 3174 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N16000000
    Vortex1/2 NPT Female32 to 6344 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N17000000
    Vortex3/4 NPT Female80 to 1,5855 15/32"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N18000000
     

    Flow, Pressure, and Temperature Transmitters for Gases

    Image of Product. Front orientation. Flow Transmitters. Flow, Pressure, and Temperature Transmitters for Gases.
    Measure and transmit flow rate, pressure, and temperature of industrial gases, such as air, argon, CO2, and nitrogen, flowing through your system. These transmitters are ideal for applications where temperature and pressure can fluctuate. To calculate flow rate, they generate a small amount of heat, then measure the cooling effect your gas has on it. Also known as transducers, these transmitters convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow, temperature, and pressure increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure correctly no matter their mounting orientation.
    A digital display makes it easy to read measurements and adjust settings based on your gas. These transmitters have two configurable outputs, and each output can only be wired for one measurement (flow rate, pressure, or temperature). Outputs configured as digital pulse send flow data using spikes of voltage that match the input voltage of the transmitter. One of the outputs can be wired for IO-Link, so you can change settings and receive error messages remotely from your PLC or computer. You’ll need an IO Link controller (not included) to connect to your interface.
    These transmitters are calibrated with air but still measure accurately when used with other gases.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    scfm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    304 Stainless Steel Body with 304 Stainless Steel Fitting
    Thermal1/2 NPT Male0.15 to 4411 13/16"±6%230 psi @ 70° F14 to 140Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4384N11000000000
    Thermal1 NPT Male0.4 to 13218 3/4"±6%230 psi @ 70° F14 to 140Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4384N1200000000
     

    Flow Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Variable Area Flow Measurement.

    Variable Area

    Flow Measurement

    Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Variable Area Flow Measurement—Variable-area transmitters determine flow rate by tracking where the liquid pushes an internal piston.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One 4-20 mA Analog Transmitter Output—4-Pole M12 Connection Plug
     
    316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting
    Variable Area1 NPT Female0.5 to 273 5/8"±5%362 psi @ 212° F14 to 212Fluoroelastomer
    18 to 32Any AngleNoIP65, IP67
    4386N1040000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fitting
    Variable Area3/4 NPT Female0.1 to 42 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4386N105000000
    Variable Area3/4 NPT Female0.1 to 62 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4386N106000000
    Variable Area3/4 NPT Female0.2 to 102 15/16"±5%580 psi @ 212° F14 to 212Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4386N107000000
     
    back to top