    Quick-Read Mitutoyo Electronic Plunger Variance Indicators with Calibration Certificate

    Image of Product. Front orientation. Variance Indicators. Quick-Read Mitutoyo Electronic Plunger Variance Indicators with Calibration Certificate.
    Image of Product. Side View. Side1 orientation. Variance Indicators. Quick-Read Mitutoyo Electronic Plunger Variance Indicators with Calibration Certificate.

    Side

    View

    These indicators come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Backlighting on the LCD changes from green to red when measurements fall outside your set tolerance, so you can check readings at a glance. They can measure TIR (total indicated runout), which determines the range of high and low spots of round parts.
    All have zero-position memory, also known as absolute (ABS) positioning, which retains the measuring position when the indicator is off. A zero-set button lets you start measuring at any point. SPC data output allows for connection to a computer or data processor.
    Distance
    Measured
    Measuring
    Increments
    Accuracy
    Contact Point
    Body
    Electrical
    Inch
    Metric,
    mm
    Inch
    Metric, mm
    Inch
    Metric
    Mounting
    Stem Dia.
    Dia.
    Lg.
    Mounting
    Thread Size
    Lg.
    Wd.
    Dp.
    Voltage,
    V AC
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    SPC Data
    Output
    Mfr. Model
    No.
    Each
    Stem Mount
    0" to 2.4"0 to 60.90.0001"
    0.00002"
    0.00005"
    0.0005
    0.001
    ±0.0001"±0.0025 mm3/8"0.197"3.006"4-48
    12 1/4"2 3/8"1 5/8"12010-Pin Mitutoyo Connector, Straight Blade26 1/2Yes543-564A00000000000000000
     
    Accessories for Variance Indicators
    10-Pin Data Cables
    10-Pin Data Cables—10-pin data cables connect the indicator to a Mitutoyo miniprocessor or multiplexer.
    Lg.
    Data Processor Connection
    Type
    For Mfr. Model No.
    Each
    40"10-Pin Mitutoyo Connector543-562A, 543-564A, LSM-950600000000000000
    80"10-Pin Mitutoyo Connector543-562A, 543-564A0000000000000
    USB Data Cables
    USB Data Cables—USB data cables connect the indicator directly to your PC.
    Electrical
    Connection
    Lg.
    For Mfr. Model
    No.
    Each
    USB-A80"543-562A, 543-564A0000000000000
    Variance Indicator Backs
    Image of Product. Front orientation. Variance Indicator Backs. Lug Back.

    Lug Back

    For Dial Indicator
    Size
    Back
    Type
    Each
    AGD Group 2Lug000000000000000
     

    Quick-Read Mitutoyo Electronic Plunger Variance Indicators

    Image of Product. Front orientation. Variance Indicators. Quick-Read Mitutoyo Electronic Plunger Variance Indicators.
    Image of Product. Side View. Side1 orientation. Variance Indicators. Quick-Read Mitutoyo Electronic Plunger Variance Indicators.

    Side

    View

    Check whether measurements are in tolerance at a glance. LCD backlighting changes from green to red to indicate when measurements fall outside your set tolerance. These indicators can measure TIR (total indicated runout), which determines the range of high and low spots of round parts. All have zero-position memory, also known as absolute (ABS) positioning, which retains the measuring position when the indicator is off. A zero-set button lets you start measuring at any point. SPC data output allows for connection to a computer or data processor.
    Distance
    Measured
    Measuring
    Increments
    Accuracy
    Contact Point
    Body
    Electrical
    Inch
    Metric,
    mm
    Inch
    Metric, mm
    Inch
    Metric
    Mounting
    Stem Dia.
    Dia.
    Lg.
    Mounting
    Thread Size
    Lg.
    Wd.
    Dp.
    Voltage,
    V AC
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    SPC Data
    Output
    Mfr. Model
    No.
    Each
    Stem Mount
    0" to 2.4"0 to 60.90.0001"
    0.00002"
    0.00005"
    0.0005
    0.001
    ±0.0001"±0.0025 mm3/8"0.197"3.006"4-48
    12 1/4"2 3/8"1 5/8"12010-Pin Mitutoyo Connector, Straight Blade26 1/2Yes543-564A00000000000000000
     
    Accessories for Variance Indicators
    10-Pin Data Cables
    10-Pin Data Cables—10-pin data cables connect the indicator to a Mitutoyo miniprocessor or multiplexer.
    Lg.
    Data Processor Connection
    Type
    For Mfr. Model No.
    Each
    40"10-Pin Mitutoyo Connector543-562A, 543-564A, LSM-950600000000000000
    80"10-Pin Mitutoyo Connector543-562A, 543-564A0000000000000
    USB Data Cables
    USB Data Cables—USB data cables connect the indicator directly to your PC.
    Electrical
    Connection
    Lg.
    For Mfr. Model
    No.
    Each
    USB-A80"543-562A, 543-564A0000000000000
    Variance Indicator Backs
    Image of Product. Front orientation. Variance Indicator Backs. Lug Back.

    Lug Back

    For Dial Indicator
    Size
    Back
    Type
    Each
    AGD Group 2Lug000000000000000
     