McMaster-Carr logo
    Filter by
    System of Measurement
    Electrical Connection Coding
    Industrial Info Snippet
    Housing Thread Size
    Industrial Info Compare
    Number of Poles
    Ethernet Cable Category
    Industrial Info Compare
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Environment
    Gender
    Maximum Temperature
    Connection End Type
    Cord Type
    DFARS Specialty Metals
    Enclosure Rating
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products

    Ethernet Cords with M12 and RJ45 Connectors

    To send high-speed data in tough, rugged environments, these cords have an M12 connector on one end that threads onto switches, sensors, and other devices prone to vibration. The other end has a traditional RJ45 plug that connects to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). These cords can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems. With TPE insulation, they stand up to bending in robotics applications. It also means they resist abrasion and won’t pit or crack from chemicals, sunlight, and welding runoff.
    Thanks to its threads and IP rating, the M12 end is water and dust tight when mated. Poles and keyways on its face adhere to standard coding layouts, which reduces the chance of mismatching connections.
    When choosing an Ethernet cord, make sure you match or exceed your network’s ethernet cable category. These cords are backward compatible—for example, a Category 6 cord will work in a Category 5 network, but it’ll only run at the Category 5 speed.
    Straight M12 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 and RJ45 Connectors, Plug, Straight End.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.
    Image of Specification. A Code. Front orientation. A Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.

    D Code

    A Code

    Image of Specification. X Code. Front orientation. X Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.

    X Code

    A Code and X Code—A- and X-coded cords send data faster than D-coded cords, so they’re best for systems that run multi-step programs, such as robotics.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed
    Transmission
    Freq., MHz
    Voltage
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    D-Coded—Category 5e Ethernet Cable
    24 1/24100 Mbit/s10030V DC1.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T902000000
     
    A-Coded—Category 5e Ethernet Cable
    24 1/281 Gbit/s10030V AC/30V DC1.824
    0.3"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T915000000
     
    X-Coded—Category 6A Ethernet Cable
    24 1/2810 Gbit/s50060V DC1.526
    0.29"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T929000000
     
    Caps
    90° Elbow M12 Plug × Straight RJ45 Plug
    Image of Product. 90° Elbow M12 Plug × RJ45 Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 and RJ45 Connectors, Straight End, 90° Elbow End, Plug.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.

    90° Elbow M12

    Plug × RJ45 Plug

    D Code

    Cords with a 90° elbow run along the side of equipment, so they fit behind machines and in tight spaces.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    D-Coded—Category 5e Ethernet Cable
    24 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T944000000
     
    Caps

    Ethernet Cords with M8 and RJ45 Connectors

    Send high-speed data between sensors, switches, or I/O modules with an M8 connection and programmable logic controllers (PLCs) and computers with a traditional RJ45 connection. Braided and foil shielding blocks signal interference from nearby equipment. And with a polyurethane rubber insulation that bends easily, these cords are ideal for applications that continuously flex such as robotics. They also resist oil. The M8 end is rated IP67 when mated, so it keeps out dust and water from temporary submersion.
    Straight M8 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M8 and RJ45 Connectors, Straight End, Plug.
    Image of Specification. A Code. Front orientation. A Code. Ethernet Cords with M8 and RJ45 Connectors, Plug.

    A Code

    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    A-Coded—Category 5 Ethernet Cable
    24 1/24100100301.526
    0.193"Polyurethane Rubber
    Double Shielded
    Braid, FoilM8 × 1 mm0 to 120UL Listed, C-UL Listed
    Green8625N160000000
     
    90° Elbow M8 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M8 and RJ45 Connectors, Straight End, 90° Elbow End, Plug.
    Image of Specification. A Code. Front orientation. A Code. Ethernet Cords with M8 and RJ45 Connectors, Plug.

    A Code

    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    A-Coded—Category 5 Ethernet Cable
    24 1/24100100301.526
    0.193"Polyurethane Rubber
    Double Shielded
    Braid, FoilM8 × 1 mm0 to 120UL Listed, C-UL Listed
    Green8625N240000000
     

    ix Industrial Cords

    Securely connect equipment in data or signal applications, such as linking a servomotor and encoder. Because they have smaller connectors than standard cords, you can connect them to smaller equipment and snake them through tighter spaces. You can even use them to create multiple connection points in a compact area. These cords have a metal locking tab that secures the connectors to sockets and is less likely to break than plastic ones if yanked or bumped. All of these cords are shielded to block interference from nearby equipment. They will connect with any ix industrial sockets that meet IEC 61076-3-124. They also meet UL data transmission standards and Canadian electrical standards. You can also use them as an alternative to cords with D-sub connectors.
    B-Coded Plug × B-Coded Plug
    Image of Product. Front orientation. ix Industrial Cords. Plug.
    Lg.,
    ft.
    Voltage
    Current,
    amp
    AWG
    No. of
    Wires
    Cord
    OD
    Shield
    Type
    Temp. Range,
    ° F
    Features
    Enclosure
    Rating
    Specs. Met
    Color
    Each
    Shielded
    24 1/250V AC/60V DC1.526
    100.25"Braid-20 to 175Locking TabIP20
    CSA C22.2 No. 182.3, IEC 61076-3-124, UL 1977Gray5702N36000000
     
    back to top