    70 Products

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    10"87056 dBA @ 5 ft.Direct1,55011/2017 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/817 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    18"3,80065 dBA @ 5 ft.Direct1,30013/425 1/4"25 1/4"27 1/2"27 1/2"26 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/431 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    Replacement Fan Motors
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors
    230/460V AC, Three Phase—Hardwire
    Cannot Be Sold to California—Fans that cannot be sold to California are restricted by local energy efficiency requirements.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Cannot Be
    Sold To
    Each
    30"8,40074 dBA @ 5 ft.Direct1,1251137 1/4"37 1/4"39 1/2"39 1/2"27 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California00000000000000000
    36"12,30074 dBA @ 5 ft.Direct85011 1/243 1/4"43 1/4"45 1/2"45 1/2"31 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California0000000000000000

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    8"40053 dBA @ 5 ft.Direct1,55011/2512 1/8"12 1/8"5 3/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000
    10"80057 dBA @ 5 ft.Direct1,55011/2016 1/8"16 1/8"8 3/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/816 1/8"16 1/8"8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    14"2,40068 dBA @ 5 ft.Direct1,55011/320 1/8"20 1/8"9 7/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    16"3,40069 dBA @ 5 ft.Direct1,55013/420 1/8"20 1/8"11 1/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    18"4,20069 dBA @ 5 ft.Direct1,55013/424 1/8"24 1/8"11 3/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    20"4,10064 dBA @ 5 ft.Direct1,07511/224 1/8"24 1/8"10 5/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/430 1/8"30 1/8"11 1/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000

    Direct-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Direct-Drive Duct Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade
    Material
    Certification
    Hardware
    Included
    Hole
    Dia.
    Each
    120V AC, Single Phase—Hardwire
    4"195 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0501/409 1/2"9 1/2"9 5/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    4"1143 ft³/min @ 3/8 in. H₂O
    168 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/910"10 1/2"10 9/16"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    150 ft³/min @ 1/8 in. H₂O
    Not Rated3,0501/409 1/2"9 1/2"7 7/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"00000000000000
    6"1201 ft³/min @ 3/8 in. H₂O
    255 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/1211 5/8"12 1/8"9 7/32"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    6"1250 ft³/min @ 3/8 in. H₂O
    308 ft³/min @ 1/8 in. H₂O
    Not Rated2,1501/611 5/8"12 1/8"9 7/32"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"000000000000000
    6"1250 ft³/min @ 3/8 in. H₂O
    300 ft³/min @ 1/8 in. H₂O
    Not Rated2,4501/1011 3/4"11 3/4"9 5/8"140ABS/PolycarbonateNylon
    C-UL Listed, UL Listed
    Yes1/4"00000000000000
     

    Direct-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Direct-Drive Corrosion-Resistant Duct Fans.
    A galvanized steel housing offers good corrosion resistance. All of these direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Also known as axial duct fans, they install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Each
    120V AC, Single Phase—Hardwire
    4"190 ft³/min @ 3/8 in. H₂O
    115 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"6 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    00000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"5 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    6"1240 ft³/min @ 3/8 in. H₂O
    280 ft³/min @ 1/8 in. H₂O
    Not Rated2,7001/1011 3/8"13 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1360 ft³/min @ 3/8 in. H₂O
    425 ft³/min @ 1/8 in. H₂O
    Not Rated2,5501/613 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1435 ft³/min @ 3/8 in. H₂O
    480 ft³/min @ 1/8 in. H₂O
    Not Rated2,9501/513 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    10"1540 ft³/min @ 3/8 in. H₂O
    570 ft³/min @ 1/8 in. H₂O
    Not Rated3,1001/413 3/8"15 3/8"5 7/8"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    12"1620 ft³/min @ 3/8 in. H₂O
    700 ft³/min @ 1/8 in. H₂O
    Not Rated2,6001/416"18"8 1/4"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
     
    120V AC, Single Phase—Plug In
    4"190 ft³/min @ 3/8 in. H₂O
    115 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"6 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    5"1105 ft³/min @ 3/8 in. H₂O
    135 ft³/min @ 1/8 in. H₂O
    Not Rated3,0001/408 3/4"10 3/4"5 1/2"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1360 ft³/min @ 3/8 in. H₂O
    425 ft³/min @ 1/8 in. H₂O
    Not Rated2,5501/613 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    8"1435 ft³/min @ 3/8 in. H₂O
    480 ft³/min @ 1/8 in. H₂O
    Not Rated2,9501/513 3/8"15 3/8"6"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
    10"1540 ft³/min @ 3/8 in. H₂O
    570 ft³/min @ 1/8 in. H₂O
    Not Rated3,1001/413 3/8"15 3/8"5 7/8"140Galvanized SteelPolypropylene
    C-UL Listed, UL Listed
    0000000000000
     

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    7"190 ft³/min @ 0 in. H₂O39 dBA @ 15 ft.Direct1,05011/258"8"8"17 1/8"13"180Aluminum
    NoC-UL Listed, UL Listed
    000000000000000000000000000000000000000
    10"250 ft³/min @ 1/4 in. H₂O
    550 ft³/min @ 0 in. H₂O
    42 dBA @ 15 ft.Direct1,05011/2510"10"10"21 1/8"16"180Aluminum
    NoC-UL Listed, UL Listed
    000000000000000000000000000000000000
    13"1,400 ft³/min @ 1/4 in. H₂O
    1,600 ft³/min @ 0 in. H₂O
    49 dBA @ 15 ft.Direct1,07511/612"12"12"30 3/16"28 3/4"180Aluminum
    NoC-UL Listed, UL Listed
    000000000000000000000000000000000000
    16"2,400 ft³/min @ 1/4 in. H₂O
    2,800 ft³/min @ 0 in. H₂O
    56 dBA @ 15 ft.Direct1,07511/314"16"16"34 11/16"30 7/8"180Aluminum
    NoC-UL Listed, UL Listed
    000000000000000000000000000000000000000
    120/230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with an open dripproof (ODP) motor enclosure should be used in clean, dry, and indoor locations. You can use these fans with or without duct. To use them with duct, you'll need an angle ring (not included).
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain.
    Grilles—Grilles (sold separately) have fixed blades.
    Louvers—Louvers are gravity operated. The blades open when air flows and close when it stops, preventing backdrafts.
    Exhaust Fans
    Grilles
    Louvers
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    Each
    18"4,000 ft³/min @ 1/4 in. H₂O
    4,300 ft³/min @ 0 in. H₂O
    58 dBA @ 15 ft.Direct1,12513/420"20"20"39 7/16"35 5/8"180Aluminum
    NoC-UL Listed, UL Listed
    00000000000000000000000000000000000000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    12"1,600Not RatedDirect1,72511/416 1/8"16 1/8"17 3/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    16"2,80061 dBA @ 15 ft.Direct1,72511/320 1/8"20 1/8"15"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    0000000000000000000000000000
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    0000000000000000000000000000
    24"6,50071 dBA @ 5 ft.Direct1,12513/430 1/8"30 1/8"29 1/8"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D
    0000000000000000000000000000
    230/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Cannot Be Sold to California—Fans that cannot be sold to California do not meet energy efficiency requirements.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Cannot Be
    Sold To
    Each
    Each
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    30"11,00077 dBA @ 5 ft.Direct1,12511 1/236 1/8"36 1/8"29 1/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    California0000000000000000000000000000
    36"15,50080 dBA @ 5 ft.Direct1,1251242 1/8"42 1/8"29 3/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    California0000000000000000000000000000

    Ceiling-Mount Lavatory Exhaust Fans

    Use these fans to draw stagnant and humid air out of a room.
    For Round or Oval Duct
    Image of Product. Style 5. Top orientation. Style 5. Ceiling-Mount Lavatory Exhaust Fans.

    Style 5

    For
    Duct
    Guard
    For
    Opening
    Mounting
    Style
    For Duct
    Dia.
    Oval
    Ht.
    Oval
    Wd.
    Airflow,
    ft³/min
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Wd.
    Dp.
    Housing
    Material
    Fasteners
    Included
    Location
    Mounting
    Hole Dia.
    Features
    Certification
    Each
    120V AC, Single Phase—Hardwire
    53"2"4"802813 3/4"13"10 1/2"4"SteelYesCeiling, Wall7/16"Backdraft-Preventing DamperC-UL Listed, UL Listed