About Wire and Cable
More
Low-Voltage Cable

- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Wd. | Thick. | Outer Insulation Color | Industry Designation | Length, ft. | 1-249 | 250-Up | |
Stranded Wire | ||||||||||
12V DC | ||||||||||
24 | 2 | 24/2 | 0.11" | 0.06" | Black, Red | GPT | 000000 | 00000 | 00000 | |
22 | 2 | 22/2 | 0.16" | 0.07" | Black, Red | GPT | 500 | 0000000 | 000 | 000 |
20 | 2 | 20/2 | 0.17" | 0.08" | Black, Red | GPT | 500 | 0000000 | 000 | 000 |
18 | 2 | 18/2 | 0.21" | 0.1" | Black, Red | GPT | 000000 | 000 | 000 | |
16 | 2 | 16/2 | 0.24" | 0.12" | Black, Red | GPT | 500 | 0000000 | 000 | 000 |
14 | 2 | 14/2 | 0.29" | 0.15" | Black, Red | GPT | 000000 | 000 | 000 | |
12 | 2 | 12/2 | 0.33" | 0.16" | Black, Red | GPT | 000000 | 0000 | 000 |
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
18-gauge wire is often used for sprinkler systems.
16-, 14-, and 12-gauge wire is designed for underground, low-voltage lighting equipment, such as landscape lighting. The wires can be separated for installation.

Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Material | Inner Insulation Color | Specifications Met | 500 ft. | |
30V AC/30V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 0.2" | Black | Polypropylene Plastic | Red, White | UL Listed | 0000000 | |
18 | 3 | 18/3 | 0.21" | Black | Polypropylene Plastic | Green, Red, White | UL Listed | 0000000 | |
18 | 4 | 18/4 | 0.23" | Black | Polypropylene Plastic | Blue, Green, Red, White | UL Listed | 0000000 | |
18 | 5 | 18/5 | 0.25" | Black | Polypropylene Plastic | Blue, Green, Red, White, Yellow | UL Listed | 0000000 | |
18 | 6 | 18/6 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Red, White, Yellow | UL Listed | 0000000 | |
18 | 7 | 18/7 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | |
18 | 8 | 18/8 | 0.29" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | |
18 | 9 | 18/9 | 0.31" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Pink, Red, White, Yellow | UL Listed | 0000000 |
Coaxial Cable



- Use For: Audio, Data, Interference Shielding, Video
- Flexible, except RG-213/U is Bend and Stay
- Max. Temperature: See table
- Insulation: PVC Plastic, except RG-316/U is FEP Plastic
Often used in radio transmission, network connections, and digital audio feed, this cable transmits audio, video, and data signals.
RG-58/U and RG-59/U cable are good for low frequency transmissions such as radio signals. RG-62A/U cable is often used in computer networks and electronics.
RG-174/U cable has a small diameter, so it’s easy to coil. RG-213/U cable has the largest diameter, so it's thicker and more robust than other coaxial cable. It is used in high frequency transmissions such as ground communications. RG-316/U cable has the smallest diameter, so it is extremely flexible for routing in tight spaces. Its FEP plastic insulation withstands high temperatures. It is often used in military equipment.
RG-6/U cable is good for medium to high frequency transmissions and is often used in satellite signal transmission.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors. Quad shielded cable has two layers of braid and two layers of foil for the most protection against signal interference and the clearest signal.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | Resistance | Wire Ga. | No. of Wires | Max. Temp., °F | OD | Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Shielded Solid Wire | ||||||||||
RG-58/U | 50 ohms | 20 | 1 | 175° | 0.2" | Black | 0000000 | 00000 | 00000 | |
RG-59/U | 75 ohms | 23 | 1 | 175° | 0.24" | Black | 000000 | 000 | 000 | |
RG-62A/U | 93 ohms | 22 | 1 | 175° | 0.24" | Black | 000000 | 0000 | 0000 | |
Shielded Stranded Wire | ||||||||||
RG-174/U | 50 ohms | 26 | 1 | 175° | 0.11" | Black | 0000000 | 000 | 000 | |
RG-213/U | 50 ohms | 13 | 1 | 140° | 0.4" | Black | 500 | 00000000 | 0000 | 0000 |
RG-316/U | 50 ohms | 24 | 1 | 390° | 0.1" | White | 500 | 00000000 | 0000 | 0000 |
Double-Shielded Solid Wire | ||||||||||
RG-6/U | 75 ohms | 18 | 1 | 165° | 0.27" | Black | 000000 | 000 | 000 | |
Quad-Shielded Solid Wire | ||||||||||
RG-6/U | 75 ohms | 18 | 1 | 165° | 0.3" | Black | 0000000 | 000 | 000 |
Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 3 | 24/3 | 10 | 12.5 pF | 0° to 165° | 0.22" | CM | Gray | Black, Green, Red | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 500 | 00000000 | 00000 | 00000 |
24 | 4 | 24/4 | 10 | 12.5 pF | 0° to 165° | 0.23" | CM | Gray | Black, Green, Red, White | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 000 | |
24 | 6 | 24/6 | 10 | 12.5 pF | 0° to 165° | 0.27" | CM | Gray | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 0000 | |
24 | 8 | 24/8 | 10 | 12.5 pF | 0° to 165° | 0.28" | CM | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 0000 | |
24 | 10 | 24/10 | 10 | 12.5 pF | 0° to 165° | 0.31" | CM | Gray | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 0000 | |
24 | 15 | 24/15 | 10 | 12.5 pF | 0° to 165° | 0.35" | CM | Gray | Black, Black/White, Blue, Blue/Black, Blue/White, Green, Green/Black, Green/White, Orange, Orange/Black, Red, Red/Black, Red/White, White, White/Black | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 0000 | |
24 | 25 | 24/25 | 10 | 12.5 pF | 0° to 165° | 0.4" | CM | Gray | Black, Black/Red, Black/White, Black/White/Red, Blue, Blue/Black, Blue/Red, Blue/White, Green, Green/Black, Green/Black/White, Green/White, Orange, Orange/Black, Orange/Green, Orange/Red, Red, Red/Black, Red/Black/White, Red/Green, Red/White, White, White/Black, White/Black/Red, White/Red | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 0000 | 0000 |
Twisted-Pair Data Communication Cable

- Use For: Data, Interference Shielding
- Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
This cable has twisted pairs of wires that cancel signal interference from multiple transmission lines, as well as foil and braid shielding over the entire cable. It's often used to transmit data in high speed computers near variable-frequency drive motors, where voltage fluctuations and current spikes can distort signals. The industry designation is CM and CMG, so it’s approved for in-wall installation and has flame-resistant insulation. The uninsulated ground wire is not counted in the number of wires.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | OD | Industry Designation | Outer Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | ||||||||||||
300V AC | ||||||||||||
24 | 4 | 24/4 | 10 | 12.5 pF | 0.27" | CM, CMG | Gray | Uninsulated Ground Wire | 00000000 | 00000 | 00000 | |
24 | 6 | 24/6 | 10 | 12.5 pF | 0.28" | CM, CMG | Gray | Uninsulated Ground Wire | 00000000 | 0000 | 0000 | |
24 | 10 | 24/10 | 10 | 12.5 pF | 0.33" | CM, CMG | Gray | Uninsulated Ground Wire | 00000000 | 0000 | 0000 | |
24 | 25 | 24/25 | 10 | 12.5 pF | 0.48" | CM, CMG | Gray | Uninsulated Ground Wire | 00000000 | 0000 | 0000 |
Ethernet Cable


- Use For:
Unshielded: Data; Category 3 can also be used for Telephones
Shielded, Double Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Send data between computers, printers, servers, and switches. Ethernet category standards describe the cable’s performance capabilities. Higher category numbers mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match, but your speed will only be as fast as the lowest-rated cable.
Unshielded cable is the choice for day-to-day wiring, such as connecting your desktop computer to an ethernet port.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment, such as variable frequency drives or small motors. It has an uninsulated ground wire that is not counted in the number of wires.
CM and CMR cable prevent the spread of flames down the length of the cable. CMR is more flame resistant than CM cable.
Inner Insulation | Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Industry Designation | Material | Color | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
3 | 16 MHz | 24 | 8 | 24/8 | 140° | 0.16" | CMR | PVC Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Gray | 000000 | 00000 | 00000 | |
5E | 100 MHz | 24 | 8 | 24/8 | 165° | 0.21" | CM | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 0000000 | 000 | 000 | ||
6 | 100 MHz | 23 | 8 | 23/8 | 165° | 0.22" | CMR | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 0000000 | 000 | 000 | ||
Shielded Solid Wire with Uninsulated Ground Wire | ||||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | CMR | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 000000 | 000 | 000 | ||
Shielded Stranded Wire with Uninsulated Ground Wire | ||||||||||||||
5E | 100 MHz | 26 | 8 | 26/8 | 140° | 0.22" | CM | Polyethylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | White | 0000000 | 000 | 000 |
Duct-Rated Ethernet Cable


- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Inner Insulation Material | Inner Insulation Color | Features | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 00000 | 00000 | ||
6 | 350 MHz | 23 | 8 | 23/8 | 165° | 0.23" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | __ | 0000000 | 0000 | 000 | ||
Shielded Solid Wire | ||||||||||||||
6 | 250 MHz | 23 | 8 | 23/8 | 140° | 0.29" | FEP Plastic | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | Uninsulated Ground Wire | Gray | 000000 | 0000 | 0000 |
Oil-Resistant Ethernet Cable


- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Max. Temperature: 165° F
- Insulation:
Inner Insulation: See table
Outer Insulation: PVC Plastic
From mines and factories to robotics, this rugged Ethernet cable sends data between sensors and switches in the grimiest places. The PVC outer insulation is treated to stand up to oil and coolants where typical PVC insulation would become brittle and crack. To make sure it doesn't kink and snap, this cable was tested under repeated bending and rubbing with little signs of wear. Higher numbers for the Ethernet category standard mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match. However, your speed will only be as fast as the lowest-rated cable.
Choose unshielded cable for most applications. When working with variable frequency drives or small motors, choose shielded cable, which has a layer of foil that protects from signal interference. It has an uninsulated ground wire that is not counted in the number of wires.
Inner Insulation | Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Material | Color | Outer Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Unshielded Solid Wire | |||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.23" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | __ | 000000 | 00000 | 00000 | |
6 | 600 MHz | 23 | 8 | 23/8 | 0.34" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | __ | 000000 | 0000 | 0000 | |
Shielded Solid Wire | |||||||||||||
5E | 100 MHz | 24 | 8 | 24/8 | 0.27" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | Uninsulated Ground Wire | 000000 | 0000 | 0000 | |
6 | 250 MHz | 23 | 8 | 23/8 | 0.27" | Polypropylene Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | Uninsulated Ground Wire | 500 | 00000000 | 0000 | 0000 |
Duct-Rated Oil-Resistant Ethernet Cable

- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Length, ft. | 1-99 | 100-Up | |
Solid Wire | |||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.19" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 00000 | 00000 | |
6 | 350 MHz | 23 | 8 | 23/8 | 0.21" | Black | Blue, Blue/White, Brown, Brown/White, Green, Green/White, Orange, Orange/White | 000000 | 0000 | 0000 |
Telephone Cable


- Use For: Telephones
- Flexible
Connect telephones and telephone blocks to a wall jack. Terminate the cable with telephone plugs or jacks (not included).
Fiber-Optic Cable

- Use For: Data
- Flexible
- Temperature Range: -40° to 155° F
- Insulation: Thermoplastic
Send data between data centers and workstations in fiber-optic networks. The thermoplastic outer insulation on this cable is flame retardant for safe indoor use, and resists water and UV light for outdoor use. Because it works both indoors and outdoors, there’s no need for a transition splice when routing the cable into buildings. Each inner fiber also has a layer of thermoplastic insulation to protect signals and add flexibility. This cable is non-conductive, so grounding or bonding is not required.
Single-mode cable is often used to send data between buildings. It has a small core diameter, which reduces signal loss. It transmits data over longer distances and has a higher bandwidth than multimode cable.
Multimode cable is often used to transmit data over short distances, such as within buildings and local area networks (LANs). It has a large core diameter, so it’s easier to terminate and install than single-mode cable. However, it has lower bandwidth.
OFNR cable is for use in vertical shafts and large facilities with multiple levels.
ONFP cable is for use in horizontal shafts, such as in ducts and above drop ceilings.
Fiber count refers to the number of optical fibers inside a cable. The higher the count, the more data you can send. You can branch each fiber into its own individual cable if your network demands grow in the future.
For technical drawings and 3-D models, click on a part number.
Fiber Count | Core Dia., microns | OD | Outer Insulation Color | Inner Insulation Color | For Use Outdoors | Specifications Met | 500 ft. | |
Single Mode OS2, OFNR | ||||||||
---|---|---|---|---|---|---|---|---|
6 | 8.3 | 0.22" | Black | Blue, Brown, Gray, Green, Orange, White | Yes | UL 2556 FT4 | 0000000 | |
12 | 8.3 | 0.26" | Black | Aqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | Yes | UL 2556 FT4 | 0000000 | |
24 | 8.3 | 0.31" | Black | Aqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Purple/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Red, Red/Black, White, White/Black, Yellow, Yellow/Black | Yes | UL 2556 FT4 | 0000000 | |
Single Mode OS2, OFNP | ||||||||
6 | 8.3 | 0.21" | Black | Blue, Brown, Gray, Green, Orange, White | Yes | NFPA 262, Flame Rated FT6 | 0000000 | |
12 | 8.3 | 0.25" | Black | Aqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | Yes | NFPA 262, Flame Rated FT6 | 0000000 | |
24 | 8.3 | 0.31" | Black | Aqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Purple/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Red, Red/Black, White, White/Black, Yellow, Yellow/Black | Yes | NFPA 262, Flame Rated FT6 | 0000000 | |
Multimode OM3, OFNR | ||||||||
6 | 50 | 0.22" | Black | Blue, Brown, Gray, Green, Orange, White | Yes | UL 2556 FT4 | 0000000 | |
12 | 50 | 0.26" | Black | Aqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | Yes | UL 2556 FT4 | 0000000 | |
24 | 50 | 0.31" | Black | Aqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Purple/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Red, Red/Black, White, White/Black, Yellow, Yellow/Black | Yes | UL 2556 FT4 | 0000000 | |
Multimode OM3, OFNP | ||||||||
6 | 50 | 0.21" | Black | Blue, Brown, Gray, Green, Orange, White | Yes | NFPA 262, Flame Rated FT6 | 0000000 | |
12 | 50 | 0.25" | Black | Aqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | Yes | NFPA 262, Flame Rated FT6 | 0000000 | |
24 | 50 | 0.31" | Black | Aqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Purple/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Red, Red/Black, White, White/Black, Yellow, Yellow/Black | Yes | NFPA 262, Flame Rated FT6 | 0000000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.

- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Length, ft. | 1-99 | 100-Up | |
300V AC/300V DC | ||||||||||||
24 | 2 | 24/2 | 0° to 165° | 0.16" | Gray | Black, Red | Uninsulated Ground Wire | CM, CMG | 500 | 00000000 | 00000 | 00000 |
24 | 3 | 24/3 | 0° to 165° | 0.16" | Gray | Black, Green, Red | Uninsulated Ground Wire | CM, CMG | 500 | 00000000 | 000 | 000 |
24 | 4 | 24/4 | 0° to 165° | 0.18" | Gray | Black, Green, Red, White | Uninsulated Ground Wire | CM, CMG | 500 | 00000000 | 000 | 000 |
24 | 6 | 24/6 | 0° to 175° | 0.21" | Gray | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CM, CMG | 00000000 | 000 | 000 | |
24 | 8 | 24/8 | 0° to 175° | 0.22" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CM, CMG | 00000000 | 000 | 000 | |
24 | 10 | 24/10 | 0° to 175° | 0.25" | Gray | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | Uninsulated Ground Wire | CM, CMG | 00000000 | 0000 | 000 | |
24 | 15 | 24/15 | 0° to 165° | 0.27" | Gray | Black, Black/White, Blue, Blue/Black, Blue/White, Green, Green/Black, Green/White, Orange, Orange/Black, Red, Red/Black, Red/White, White, White/Black | Uninsulated Ground Wire | CM, CMG | 500 | 00000000 | 0000 | 0000 |
24 | 25 | 24/25 | 0° to 175° | 0.37" | Gray | Black, Black/Red, Black/White, Black/White/Red, Blue, Blue/Black, Blue/Red, Blue/White, Green, Green/Black, Green/Black/White, Green/White, Orange, Orange/Black, Orange/Green, Orange/Red, Red, Red/Black, Red/Black/White, Red/Green, Red/White, White, White/Black, White/Black/Red, White/Red | Uninsulated Ground Wire | CM, CMG | 00000000 | 0000 | 0000 |
Flat Control Cable

- Use For: Automation
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Also known as festoon cable, this flat cable fits in confined spaces and withstands period flexing and bending, such as in overhead cranes and hoists. Use it to operate, measure, or regulate automated equipment. The PVC insulation resists oil and UV light. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | Per Ft. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
16 | 8 | 16/8 | 15 A @ 86° F | 1.11" | 0.2" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | |
16 | 12 | 16/12 | 15 A @ 86° F | 1.61" | 0.2" | Yellow | Black, Blue, Blue/Black, Brown, Brown/Black, Orange, Orange/Black, Red, Red/Black, Yellow, Yellow/Black | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | |
14 | 4 | 14/4 | 25 A @ 86° F | 0.69" | 0.24" | Yellow | Black, Blue, Orange, Red | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | |
14 | 8 | 14/8 | 25 A @ 86° F | 1.33" | 0.24" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 500 | 00000000 | 0000 |
14 | 12 | 14/12 | 20 A @ 86° F | 1.81" | 0.23" | Yellow | Black, Blue, Blue/Black, Brown, Brown/Black, Orange, Orange/Black, Red, Red/Black, Yellow, Yellow/Black | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | |
12 | 4 | 12/4 | 30 A @ 86° F | 0.71" | 0.23" | Yellow | Black, Blue, Orange, Red | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | |
12 | 8 | 12/8 | 30 A @ 86° F | 1.34" | 0.23" | Yellow | Black, Blue, Blue/Black, Brown, Orange, Red, Red/Black, Yellow | UL Listed, CSA Certified, UL 2556 VW-1 | 500 | 00000000 | 0000 |
10 | 4 | 10/4 | 40 A @ 86° F | 0.88" | 0.27" | Yellow | Black, Blue, Orange, Red | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | |
8 | 4 | 8/4 | 63 A @ 86° F | 1.19" | 0.37" | Yellow | Black, Blue, Orange, Red | UL Listed, CSA Certified, UL 2556 VW-1 | 500 | 00000000 | 0000 |
6 | 4 | 6/4 | 83 A @ 86° F | 1.45" | 0.43" | Yellow | Black, Blue, Orange, Red | UL Listed, CSA Certified, UL 2556 VW-1 | 500 | 00000000 | 00000 |