Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
Light Duty Power Cords





Use SJT cords in dry or damp locations.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
NEMA 6-15 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
IEC C14 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.33" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
Electronic Equipment Power Cords












Use these cords with computers, lab equipment, and office machines that have IEC connections.
Cords with a 90° elbow socket fit flush against equipment, so equipment can be pushed against a wall.
SPT cords have a flat cord shape so they fit in tight spaces.
Use SJT cords in dry or damp environments.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × IEC C7 Socket | ||||||||||||
18 | 7 | 125V AC | 6 1/2 | __ | 0.25" | PVC Plastic | SPT-2 | -30° to 220° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
NEMA 1-15 Plug × IEC C17 Socket | ||||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.3" | __ | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × IEC C13 Socket | ||||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × IEC C15 Socket | ||||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.31" | __ | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
NEMA 5-15 Plug × 90° Elbow IEC C13 Socket | ||||||||||||
16 | 13 | 125V AC | 6 1/2 | 0.35" | __ | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
IEC C14 Plug × IEC C13 Socket | ||||||||||||
17 | 10 | 250V AC | 6 1/2 | 0.28" | __ | PVC Plastic | __ | 35° to 165° | IEC 60320 | Black | 00000000 | 00000 |
IEC C20 Plug × IEC C19 Socket | ||||||||||||
14 | 15 | 250V AC | 6 1/2 | 0.32" | __ | PVC Plastic | SJT | -40° to 155° | UL Listed, C-UL Listed, IEC 60320 | Black | 00000000 | 00000 |
Locking International Electronic Equipment Power Cords




Create a vibration-resistant connection—the socket on these cords securely locks onto any male receptacle and will not detach until manually unlocked. They also have a 90° elbow plug that fits flush against a wall outlet, so they fit behind machinery and in other areas where space is tight. Use them with computers, lab equipment, and office machines that have IEC connections.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Country Compatibility | Connections | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Temp. Range, °F | Specifications Met | Color | Each | |
90° Elbow Plug × Socket | |||||||||||
France Germany Italy Spain | CEE 7/7 Plug × IEC C13 Socket | 10 | 250V AC | 6 1/2 | 0.28" | PVC Plastic | -40° to 155° | IEC 60320 | Black | 000000 | 000000 |
Hong Kong Ireland United Kingdom | BS 1363 Plug × IEC C13 Socket | 10 | 250V AC | 6 1/2 | 0.28" | PVC Plastic | -40° to 155° | IEC 60320 | Black | 000000 | 00000 |
Shielded Electronic Equipment Power Cords



The shielding blocks signal interference from nearby equipment and devices. Use these cords with computers, lab equipment, and office machines that have IEC connections.
SVT cords are ultra-flexible and as pliable as vacuum cleaner cords. They withstand repeated winding.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Shield Type | Color | Each | |
NEMA 5-15 Plug × IEC C13 Socket | ||||||||||||
18 | 10 | 125V AC | 6 1/2 | 0.25" | PVC Plastic | SVT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Foil | Black | 00000000 | 000000 |
18 | 10 | 125V AC | 6 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Foil | Black | 00000000 | 00000 |
Locking Electronic Equipment Power Cords



Create a vibration-resistant connection—the socket on these cords securely locks onto any male receptacle and will not detach until manually unlocked. Use them with computers, lab equipment, and office machines that have IEC connections.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × IEC C19 Socket | |||||||||||
14 | 15 | 125V AC | 6 1/2 | 0.14" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 000000 |
Micro M12 Cords
The threaded ends on these cords seal out contaminants and resist coming loose from vibration in tough industrial environments and automated systems while sending power and signal to devices with M12 connections. Poles and keyways on the connector face adhere to standard coding layouts, reducing the chance of mismatching connections during setup.
A-coded cords work with AC and DC sensors, actuators, motors, light curtains, and other devices. They’re also often used to connect equipment to IO Link controllers and within Profibus, DeviceNet, and other fieldbus systems.
Cords with PVC insulation work well in general purpose applications, but they shouldn’t be used outdoors. While flexible, these cords aren’t as flexible as cords with polyurethane or TPE insulation, making them best for stationary jobs. Cords with polyurethane or TPE insulation resist chemicals and sunlight, so you can use them outdoors. Because they stand up to bending, they’re good for jobs with continuous motion, such as robotics. Polyurethane also resists oil and is halogen free, which can corrode metal and is dangerous to inhale.
Use unshielded cords in applications where signal interference isn’t a concern. Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, reducing the chance of signal loss between equipment.
Cords with a 90° elbow run along the side of equipment, so they fit behind machines and in tight spaces.
When mated, the connectors are IP rated to block out dust and water if briefly submersed. IP66K rated connectors can be sprayed down during high-pressure washdowns.
Add caps to protect connectors and maintain their IP ratings when not in use.





Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Shield Type | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
8 | A | 0.3" | 6 1/2 | 2 | 30V AC/30V DC | M12 | 24 | 0.23" | Polyurethane Rubber | -10° to 185° | Double Shielded | Braid, Foil | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CE Marked, CSA-US Certified, C-UL Recognized Component, UL Recognized Component | 0000000 | 0000000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||||
4 | A | 0.3" | 6 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | __ | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 00000000 | 00000 |
5 | A | 0.3" | 6 1/2 | 4 | 30V AC/30V DC | M12 | 22 | 0.2" | PVC Plastic | -10° to 185° | Unshielded | __ | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 00000000 | 00000 |
Harsh Environment Micro M12 Cords
TPE insulation protects these cords from some of the toughest industrial conditions, including abrasion, coolants, chemicals, UV rays, and weld slag. Use them in areas with welding, machining, and fluctuating temperatures to send signal and power to M12 proximity switches, valves, and other devices. These cords are flexible and have threaded ends for a secure connection that withstands the movement and vibration of automated lines and robotics. When mated, they’re NEMA or IP rated to seal out dust and water from washdowns. Standardized pole and keyway coding layouts prevent accidental mis-mating during setup.
Cords with silicone outer insulation give you an extra layer of protection from weld slag and chemicals compared to TPE alone. They're useful in areas where frequent hot liquid splatter might burn through your cord. However, this additional layer makes them less flexible than plain TPE cords.
A-coded cords work with both AC and DC devices. They’re also often used to connect equipment to IO Link controllers and in Profibus, DeviceNet, and other fieldbus systems.
An IP69 rating means they seal out high-pressure, high-temperature washdowns.
Add caps to protect connectors and maintain their NEMA or IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.



No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | Cord OD | Cord Insulation Material | Cord Outer Insulation Material | Max. Temp., °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.375" | TPE Rubber | Silicone Rubber | 390° | IP69 | UL Listed | 0000000 | 0000000 |
5 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.375" | TPE Rubber | Silicone Rubber | 390° | IP69 | UL Listed | 0000000 | 000000 |
Stainless Steel Armored Micro M12 Cords
Step on or roll carts and platform trucks over these M12 cords without crushing them. A protective layer of stainless steel makes these the most crush- and abrasion-resistant M12 cords we offer. It also prevents damage from pests that chew through cords. The stainless steel and PVC outer layer keep moisture from corroding the cord, so they can be used outdoors and near chemicals as well. Despite the stainless steel covering, these cords are still flexible enough to route around equipment. Threaded ends create a tight connection that seals out contaminants and won’t shake loose from the vibration of automated machines.
These cords have a standardized code layout to reduce the chances of accidentally mis-mating them. All are A-coded to send signal and power to AC and DC devices. A-coded cords are often used with sensors, actuators, and motors in automated systems. They also connect devices to IO Link controllers and within fieldbus systems, such as Profibus and DeviceNet.
When mated or capped, these cords meet IP ratings. IP67 cords withstand temporary submersion. IP69 cords are protected from dust and high-pressure, high-temperature washdowns.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: Sockets may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.




No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | Cord OD | Cord Insulation Material | Cord Outer Insulation Material | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 0000000 |
5 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
Mini Cords
With a higher maximum current than nano M8 and micro M12 cords, these mini cords are often used with automated systems, motors, and pumps. A threaded housing securely mates with other mini connections and won’t shake loose from vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors. These cords are unshielded, so they’re best for use where signal interference is not a concern.
When mated, these cords meet IP ratings for protection from dust and temporary submersion.
Thread adapters connect plugs and sockets that both have internal threads.
Caps protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.




Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||
3 | 0.563" | 6 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 000000 |
4 | 0.563" | 6 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.563" | 6 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||
3 | 0.563" | 6 1/2 | 12 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
4 | 0.563" | 6 1/2 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |
5 | 0.563" | 6 1/2 | 9 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | PVC Plastic | -10° to 175° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 0000000 | 00000 |

Thread Size | Material | Each | |
External Thread | |||
---|---|---|---|
7/8"-16 | Aluminum | 00000000 | 00000 |
For Face Dia. | Thread Size | Material | Includes | Each | |
External Thread | |||||
---|---|---|---|---|---|
0.55" | 7/8"-16 | Epoxy-Coated Zinc | Lanyard | 00000000 | 000000 |
Nano M8 Cords






Also known as pico cords, these cords are often used with low-current 8 mm proximity and photoelectric switches.
Cords with polyurethane insulation bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil.
Cords with 90° elbow plugs and sockets fit flush against equipment, so they fit in tight spaces.
All are rated IP67 for protection from dust and temporary submersion. Cords rated IP66K also protect against washdowns.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Color | Shielding | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
3 | A | 0.2" | 6 1/2 | 4 | 60V AC/75V DC | M8 | 24 | 0.17" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
4 | A | 0.2" | 6 1/2 | 4 | 60V AC/75V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
5 | B | 0.2" | 6 1/2 | 3 | 60V AC/75V DC | M8 | 24 | 0.2" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
8 | A | 0.2" | 6 1/2 | 1.5 | 30V AC/30V DC | M8 | 14 | 0.22" | Polyurethane Rubber | Black | Unshielded | -20° to 175° | IP67 | C-UL Recognized Component, UL Recognized Component | 0000000 | 00000 |
Plug (External Thread) × 90° Elbow Socket (Internal Thread) | ||||||||||||||||
3 | A | 0.2" | 6 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
4 | A | 0.2" | 6 1/2 | 4 | 30V AC/30V DC | M8 | 24 | 0.19" | PVC Plastic | Yellow | Unshielded | -20° to 175° | IP66K, IP67 | UL Listed, C-UL Listed, CSA Certified, CSA-US Certified | 0000000 | 00000 |
Harsh Environment Nano M8 Cords



Send signal and power to low-current devices with M8 connections near welding, metal machining, and in spots where temperatures change. These cords stand up to chemicals, oil, weld slag, and other tough industrial stresses thanks to a layer of TPE. They’re flame rated FT4, so they meet requirements for preventing the spread of flames. Also known as pico cords, M8 cords are often used with 8 mm and smaller proximity switches and photoelectric switches. These cords are good for robotics and other jobs with continuous motion because TPE bends easily.
All are rated IP66K and IP67 when mated for protection against dust, temporary submersion, and high-pressure washdowns. UL and C-UL listed, they meet American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.
Housing Thread | Cord | 6 1/2 ft. Lg. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Current, A | Voltage | Size | Pitch, mm | Wire Gauge | OD | Insulation Material | Color | Temperature Range, ° F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||
3 | A | 4 | 30V AC/30V DC | M8 | 1 | 22 | 0.19" | TPE Rubber | Yellow | -10° to 185° | IP66K, IP67 | UL Listed, C-UL Listed, UL 2556 FT4 | 0000000 | 000000 |
4 | A | 4 | 30V AC/30V DC | M8 | 1 | 22 | 0.21" | TPE Rubber | Yellow | -10° to 185° | IP66K, IP67 | UL Listed, C-UL Listed, UL 2556 FT4 | 0000000 | 00000 |
Nano M8/Micro M12 Adapter Cords





These cords have an M8 connector on one end and an M12 connector on the other. With polyurethane insulation, they bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil. They’re rated IP65, IP68 and IP69K for protection from temporary submersion and high-pressure, high-temperature washdowns.
For technical drawings and 3-D models, click on a part number.
Plug | Socket | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing Thread Size | No. of Poles | Face Dia. | Housing Thread Size | No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Wire Gauge | OD | Insulation Material | Environmental Rating | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | |||||||||||||||
A-Coded—Unshielded | |||||||||||||||
M8 | 3 | 0.2" | M12 | 5 | 0.3" | 6 1/2 | 3 | 50V AC/60V DC | 22 | 0.19" | Polyurethane Rubber | IP65, IP68, IP69K | Black | 0000000 | 000000 |
M8 | 4 | 0.2" | M12 | 5 | 0.3" | 6 1/2 | 3 | 50V AC/60V DC | 22 | 0.19" | Polyurethane Rubber | IP65, IP68, IP69K | Black | 0000000 | 00000 |
M12 | 3 | 0.3" | M8 | 3 | 0.2" | 6 1/2 | 3 | 50V AC/60V DC | 22 | 0.19" | Polyurethane Rubber | IP65, IP68, IP69K | Black | 0000000 | 00000 |
M12 | 3 | 0.3" | M8 | 4 | 0.2" | 6 1/2 | 3 | 50V AC/60V DC | 22 | 0.19" | Polyurethane Rubber | IP65, IP68, IP69K | Black | 0000000 | 00000 |
M29 Power Cords


Often used in automation systems such as conveyors and sorters, these cords have plug and socket ends, so they quickly connect and disconnect for maintenance and do not need to be hardwired. Because these cords carry higher currents than micro and mini cords, they can power equipment such as motors, fans, pumps, and automated machine tools. They are shielded to block out interference from nearby equipment. These cords meet UL 2237 and UL 2238, so they can be used in motor branch circuits of industrial machinery. They also meet TC-ER crush and impact requirements for exposed runs in cable carriers. IP rated, they protect against dust, washdowns, and temporary submersion.
Connect these cords to control cabinets and equipment with M29 power receptacles (sold separately).
For technical drawings and 3-D models, click on a part number.
Housing Thread | Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Shielded Plug (External Thread) × Shielded Socket (Internal Thread) | |||||||||||||||
4 | 1" | 6 1/2 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 0000000 | 0000000 |
M35 Power Cords
Like a tree trunk connecting to branches, these cords supply power to a chain of devices. Send power to high-amperage motors, robotic arms, and other machines in motor controls, conveyors, and sorting and packaging systems. All quickly connect and disconnect for easy installation and maintenance.
UL and C-UL listed, these cords meet American and Canadian safety standards. They comply with TC-ER requirements, so they withstand being hit and crushed when exposed. Their inner and outer insulation resist oil and water as well, thanks to their STOOW rating. IP and NEMA rated when connected, these cords resist corrosion and seal out dust and water from weather and washdowns. You can even safely submerse them for brief periods of time.
Attach M35 connectors or M22 cords and connectors to extend your power line and reach more devices in your system. Connecting tees link multiple pieces of equipment with M35 connections. Reducing tees join equipment with M35 connections to equipment with M22 connections.
Add a cap to protect these cords from dust when they’re not in use.
Optional locking clips stop your cord from coming loose when powering equipment that carries high amperage.
For technical drawings and 3-D models, click on a part number.


Housing Thread | Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
4 | 0.87" | 6 1/2 | 25 | 600V AC/600V DC | 1 3/8"-16 | UNS | 10 | 0.72" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 0000000 |

Housing Thread | ||||||
---|---|---|---|---|---|---|
Face Dia. | Size | Type | Housing Material | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) × Socket (Internal Thread) | ||||||
0.87" | 1 3/8"-16 | UNS | PVC Plastic | Black | 0000000 | 0000000 |


Face Dia. | Housing Thread Size | ||||||||
---|---|---|---|---|---|---|---|---|---|
(A) | (B) | (C) | (A) | (B) | (C) | Housing Material | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) × Socket (Internal Thread) | |||||||||
0.87" | 0.59" | 0.87" | 1 3/8"-16 UNS | 7/8"-16 UNS | 1 3/8"-16 UNS | PVC Plastic | Black | 0000000 | 000000 |

Material | Color | Each | |
PVC Plastic | Black | 0000000 | 00000 |
Solenoid Valve Cords
Use these cords with hydraulic and air-powered valves, motors, pumps, and pressure switches. They have a solenoid valve socket on one end and an M12 threaded plug on the other. The ground connection is not included in the number of poles. A power-indicating light on the socket illuminates when the cord has power. All are IP-rated for protection from washdowns and temporary submersion.
For technical drawings and 3-D models, click on a part number.

Socket | Plug | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DIN Type | Contact Distance | Housing Thread Size | Coding | No. of Poles | No. of Ground Connections | Lg., ft. | Wire Gauge | Current, A | Voltage | OD | Insulation Material | Environmental Rating | Specifications Met | Each | |
90° Elbow Socket × Plug (External Thread) | |||||||||||||||
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 000000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |

For Thread Size | Material | Includes | Each | |
For Plugs | ||||
---|---|---|---|---|
M12 | Anodized Aluminum | Lanyard | 0000000 | 000000 |
Quick-Connect Screw-Together Power Cords
A few turns is all it takes to join these cords, which have thick threads similar to a light bulb, for a secure connection in washdown and high-vibration areas. They detach just as fast for frequent maintenance. IP68 rated when mated, these cords block out dust and water if briefly submersed. They carry higher currents than mini cords, so they’re often used to power cameras, machine tools, HVAC equipment, and I/O modules, yet they’re compact to save space. Their housing resists UV rays for outdoor use. All have cables that are known as TC-ER, meaning they meet crush and impact requirements for exposed cable in cable carriers.
Connect these cords to mating quick-connect connectors.
Add caps to keep out dust and debris when these cords aren’t connected.
For technical drawings and 3-D models, click on a part number.


Housing Thread | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | No. of Poles | Face Dia. | Current, A | Voltage | Wire Gauge | Size | Pitch | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Each | |
IP68 Rated | ||||||||||||||
6 1/2 | 4 | 0.53" | 16 | 400V AC/400V DC | 14 | Rd 24-8 | 3.18mm | 0.39" | PVC Plastic | TC-ER | -40° to 210° | UL Listed | 00000000 | 000000 |
M22 Power Cords
Similar to branches extending from a tree, these cords disperse power from a main power line to run a chain of devices. Power high-amperage fans, pumps, and other machines in motor controls, conveyors, and sorting and packaging systems. All quickly connect and disconnect for easy installation and maintenance.
These cords are UL and C-UL listed, so they meet American and Canadian safety standards. They comply with TC-ER requirements, meaning they withstand being hit and crushed when exposed. An STOOW rating means their inner and outer insulation resist oil and water. IP and NEMA rated when connected, these cords resist corrosion and seal out dust and water from weather and washdowns. They can even be under water for brief periods of time.
Lengthen your power line and reach more devices in your system by adding M22 connectors or M35 cords and connectors. Reducing tees join equipment with M22 connections to equipment with M35 connections.
Add a cap to protect these cords from dust when they’re not in use.
Optional locking clips stop your cord from coming loose when used with equipment that carries high amperage.
For technical drawings and 3-D models, click on a part number.


Housing Thread | Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
4 | 0.59" | 6 1/2 | 15 | 600V AC/600V DC | 7/8"-16 | UNS | 14 | 0.57" | PVC Plastic | STOOW, TC-ER | -40° to 190° | NEMA 6P, IP67 | UL Listed, C-UL Listed, UL 2237 | Black | 0000000 | 000000 |


Face Dia. | Housing Thread Size | ||||||||
---|---|---|---|---|---|---|---|---|---|
(A) | (B) | (C) | (A) | (B) | (C) | Housing Material | Color | Each | |
Plug (External Thread) × Socket (Internal Thread) × Socket (Internal Thread) | |||||||||
0.87" | 0.59" | 0.87" | 1 3/8"-16 UNS | 7/8"-16 UNS | 1 3/8"-16 UNS | PVC Plastic | Black | 0000000 | 000000 |

Material | Color | Each | |
PVC Plastic | Black | 0000000 | 00000 |
Ethernet Cords with M12 and RJ45 Connectors
To send high-speed data in tough, rugged environments, these cords have an M12 connector on one end that threads onto switches, sensors, and other devices prone to vibration. The other end has a traditional RJ45 plug that connects to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). These cords can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems. With TPE insulation, they stand up to bending in robotics applications. It also means they resist abrasion and won’t pit or crack from chemicals, sunlight, and welding runoff.
Thanks to its threads and IP rating, the M12 end is water and dust tight when mated. Poles and keyways on its face adhere to standard coding layouts, which reduces the chance of mismatching connections.
When choosing an Ethernet cord, make sure you match or exceed your network’s ethernet cable category. These cords are backward compatible—for example, a Category 6 cord will work in a Category 5 network, but it’ll only run at the Category 5 speed.
A- and X-coded cords send data faster than D-coded cords, so they’re best for systems that run multi-step programs, such as robotics.
Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
Add caps to protect connectors and maintain their IP rating when not in use.
For technical drawings and 3-D models, click on a part number.




Lg., ft. | Number of Poles | Transmission Speed | Wire Gauge | Cord OD | Shielding | Shield Type | Temperature Range, °F | Cord Insulation Material | Color | Each | |
D-Coded—Ethernet Cable Category 5E | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 Mbps | 24 | 0.26" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |
A-Coded—Ethernet Cable Category 5E | |||||||||||
6 1/2 | 8 | 1 Gb/s | 24 | 0.3" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 00000 |
X-Coded—Ethernet Cable Category 6A | |||||||||||
6 1/2 | 8 | 10 Gb/s | 26 | 0.29" | Double Shielded | Braid, Foil | -40° to 175° | TPE Rubber | Blue | 00000000 | 000000 |


Lg., ft. | Number of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temperature Range, °F | Cord Insulation Material | Color | Each | |
D-Coded—Ethernet Cable Category 5E | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 | 24 | 0.26" | Double Shielded | Braid, Foil | -10° to 175° | TPE Rubber | Blue | 0000000 | 000000 |
Ethernet Cords with M12 Connectors
The M12 threaded ends on these cords seal out contaminants and resist coming loose from vibration better than the RJ45 ends on traditional Ethernet cords. Use them in tough, rugged environments to send high-speed data between sensors, switches, servers, computers, and PLCs not protected by control panels. These cords can power devices as they send data, as long as devices are Power over Ethernet (PoE) compatible. They are often used within Ethernet/IP, Profinet, and EtherCat systems. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connections.
All cords are backward compatible, so they work in networks that meet the same or lower ethernet cable category. For example, a Category 6 cord will work in a Category 5 network, but it will only run at the Category 5 speed.
A- and X-coded cords send data faster than D-coded cords, so they’re good for robotics and multi-step programs.
With either TPE or polyurethane insulation, all cords stand up to harsh factory conditions, chemicals, and UV rays. All are also highly flexible, so they’re good for jobs with continuous motion, such as robotics. TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff. Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, preventing impact to transmission speeds and data.
90° elbow cords sit flush against equipment, so they fit behind machinery in areas where space is tight.
When mated, all cords are IP67 rated to protect against dust and temporary submersion. IP65-rated cords stand up to washdowns. IP66K-rated cords stand up to high-pressure washdowns.
Add caps to protect cords and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Lg., ft. | No. of Poles | Transmission Speed | Wire Gauge | Cord OD | Specifications Met | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
A-Coded—5E Ethernet Cable Category | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 8 | 1 Gb/s | 24 | 0.3" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67 | TPE Rubber | Blue | 0000000 | 000000 |






Lg., ft. | No. of Poles | Transmission Speed | Wire Gauge | Cord OD | Specifications Met | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
D-Coded—5E Ethernet Cable Category | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 Mbps | 24 | 0.26" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 000000 |
A-Coded—5E Ethernet Cable Category | |||||||||||||
6 1/2 | 8 | 1 Gb/s | 24 | 0.3" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 00000 |
X-Coded—6A Ethernet Cable Category | |||||||||||||
6 1/2 | 8 | 10 Gb/s | 26 | 0.29" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | 0° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 000000 |




Lg., ft. | No. of Poles | Transmission Speed | Wire Gauge | Cord OD | Specifications Met | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
D-Coded—5E Ethernet Cable Category | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 Mbps | 24 | 0.26" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 000000 |
A-Coded—5E Ethernet Cable Category | |||||||||||||
6 1/2 | 8 | 1 Gb/s | 24 | 0.3" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 00000 |
X-Coded—6A Ethernet Cable Category | |||||||||||||
6 1/2 | 8 | 10 Gb/s | 26 | 0.29" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | 0° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 000000 |




Lg., ft. | No. of Poles | Transmission Speed | Wire Gauge | Cord OD | Specifications Met | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
D-Coded—5E Ethernet Cable Category | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 Mbps | 24 | 0.26" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 000000 |
A-Coded—5E Ethernet Cable Category | |||||||||||||
6 1/2 | 8 | 1 Gb/s | 24 | 0.3" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | -10° to 175° | IP65, IP67, IP66K | TPE Rubber | Blue | 0000000 | 00000 |
Ethernet Cords with M8 and RJ45 Connectors
Send high-speed data between sensors, switches, or I/O modules with an M8 connection and programmable logic controllers (PLCs) and computers with a traditional RJ45 connection. Braided and foil shielding blocks signal interference from nearby equipment. And with a polyurethane insulation that bends easily, these cords are ideal for applications that continuously flex such as robotics. They also resist oil. The M8 end is rated IP67 when mated, so it keeps out dust and water from temporary submersion.
For technical drawings and 3-D models, click on a part number.


Lg., ft. | Number of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temperature Range, °F | Cord Insulation Material | Color | Each | |
A-Coded—Ethernet Cable Category 5 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 | 26 | 0.193" | Double Shielded | Braid, Foil | 0° to 120° | Polyurethane Rubber | Green | 0000000 | 000000 |


Lg., ft. | Number of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temperature Range, °F | Cord Insulation Material | Color | Each | |
A-Coded—Ethernet Cable Category 5 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 100 | 26 | 0.193" | Double Shielded | Braid, Foil | 0° to 120° | Polyurethane Rubber | Green | 0000000 | 000000 |
Ethernet Cords with M8 Connectors




Unlike the RJ45 ends on traditional Ethernet cords, the threaded M8 ends on these cords keep contaminants out and resist coming loose from vibration. They are often used with sensors, switches, I/O modules, and computers. Braided shielding protects against signal interference. Insulated with polyurethane, these cords bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil. When mated, they are IP67 rated for protection from dust and temporary submersion.
A-coded cords work with EtherCAT connections that have the same pole configuration.
D-coded cords are Power over Ethernet (POE) enabled to carry data and power within one cord.
For technical drawings and 3-D models, click on a part number.
Lg., ft. | No. of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Specifications Met | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
M8 Plug × M8 Plug | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A-Coded—Ethernet Cable Category 5 | |||||||||||||
6 1/2 | 4 | 100 | 26 | 0.2" | UL Listed, C-UL Listed | Double Shielded | Braid, Foil | 0° to 120° | IP67 | Polyurethane Rubber | Green | 0000000 | 000000 |
D-Coded—Ethernet Cable Category 5 | |||||||||||||
6 1/2 | 4 | 100 | 22 | 0.2" | __ | Shielded | Braid | -20° to 175° | IP67 | Polyurethane Rubber | Green | 0000000 | 00000 |
USB Cords
Connect devices such as computers, printers, and mobile devices. The higher the USB standard, the faster cords can transmit data. These cords are backward compatible, so they work with cords and connectors that meet the same or lower USB standard.

Lg., ft. | Shielding | Color | Each | |
USB 3.2 Gen 1—5Gb/s Transmission Speed | ||||
---|---|---|---|---|
6 1/2 | Unshielded | Black | 00000000 | 000000 |
USB Adapter Cords
Adapt your USB port to connect to a variety of other devices. These USB cords are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Double-shielded cords have insulation, so they reduce signal interference from nearby equipment and devices.
For technical drawings and 3-D models, click on a part number.

Length, ft. | Application | Apple Compatible Connection Type | Shielding | Shield Type | Color | Specifications Met | Each | |
USB 2.0—480Mbps Transmission Speed | ||||||||
---|---|---|---|---|---|---|---|---|
6 1/2 | Data/Power | 8-Pin Lightning | Double Shielded | Foil | Black | MFi Certified | 0000000 | 000000 |
Wet-Location USB Cords
Rated IP67, these cords withstand wet and dusty locations, such as enclosures on CNC machines. These cords have braided and foil shielding, so they reduce signal interference from nearby equipment and devices. All are backward compatible, so they work with cords and connectors that meet the same or lower USB standard.
Cords with a socket mount onto a panel.
Caps (sold separately) maintain the IP rating when not in use.
For technical drawings and 3-D models, click on a part number.

Lg., ft. | USB Standard | Transmission Speed, Mbps | Shielding | Shield Type | Environment | Environmental Rating | Color | Each | |
6 1/2 | 2.0 | 480 | Double Shielded | Braid, Foil | Submersible, Dusty | IP67 | Black | 0000000 | 000000 |
Coiled USB Cords
Stretch these cords out when you need extra length and their coiled design springs back when it’s not needed to make them smaller. Their coil resists tangling. They are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Double-shielded cords have braided and foil insulation, so they reduce signal interference from nearby equipment and devices.
For technical drawings and 3-D models, click on a part number.

Length, ft. | Retracted Length, ft. | USB Standard | Transmission Speed, Mbps | Shielding | Shield Type | Color | Each | |
6 1/2 | 1 5/8 | 2.0 | 480 | Double Shielded | Braid, Foil | Black | 0000000 | 000000 |
Profibus Cords
Often used in assembly line networks and Fieldbus connections, these cords have B-coded M12 connections. The ends are threaded to withstand the vibration and shaking of an automated assembly line. Shielded with both braid and foil, these cords block interference from nearby devices, maintaining their signal integrity. PVC insulation protects these cords and resists abrasion, though it contains halogen. When mated or capped, these cords are IP67 rated, so they withstand dust and temporary submersion.
The socket end has an extra hole on the face that is not wired.
Add caps to protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Lg., ft. | Number of Poles | Transmission Speed, kbps | Wire Ga. (No. of Wires) | Cord OD | Specifications Met | Shield Type | Temperature Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
B-Coded M12 Plug × B-Coded M12 Socket | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
6 1/2 | 4 | 20 | 22 (2) | 0.31" | UL Listed | Braid, Foil | -20° to 175° | IP67 | PVC Plastic | Purple | 000000 | 000000 |
Screw-Together Wet-Location RJ45 Connectors and Cords
Use these connectors and cords to make Ethernet connections.
IP67 rated connectors and cords are protected against dust and temporary submersion when mated.
For connectors and cords that are rated both IP67 and IP20, the screw-together plug is rated IP67, and the other plug is rated IP20 for protection against objects larger than 12.5 mm, such as fingers, when mated.
For technical drawings and 3-D models, click on a part number.

6 1/2 ft. Lg. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Cord OD | Flexibility | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||||
26 | 0.29" | Flexible | Category 5E | 100 MHz | 4 | Black | Plastic | IP67 | 0° to 175° | 0000000 | 000000 |

6 1/2 ft. Lg. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Cord OD | Flexibility | For Cable Industry Designation | Transmission Frequency | Number of Wires | Color | Housing Material | Environmental Rating | Temp. Range, °F | Each | |
Unshielded | |||||||||||
24 | 0.25" | Flexible | Category 5E | 100 MHz | 4 | Black | Plastic | IP20, IP67 | 0° to 175° | 0000000 | 000000 |
Screw-Together Wet-Location HDMI Connectors and Cords
Audio/video HDMI connectors and cords are rated IP67 when mated.
UL 94 V-0 rating applies to HDMI housing.
Caps (sold separately) protect sockets and maintain the IP67 rating when not in use.
For technical drawings and 3-D models, click on a part number.

6 1/2 ft. Lg. | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Panel Cutout Dia. | Wire Gauge | Cord OD | Color | Housing Material | Environmental Rating | Specifications Met | Temp. Range, °F | Each | |
0.82" | 28 | 0.287" | Black | Plastic | IP67 | UL 94 V-0 | 0° to 175° | 0000000 | 000000 |
Cords for Programmable Logic Controllers

Use these cords to connect PLC expansion modules and keep everything configured on one processor. Rated IP20, they prevent accidental shocks by keeping internal circuits fully enclosed. They’re also UL and C-UL listed, CE marked, and CSA certified to meet various domestic and international safety standards. Total cord length for your entire system should not exceed 39 ft.
For technical drawings and 3-D models, click on a part number.
Lg., ft. | Cord OD | Color | Temperature Range | Each | |
For Omron CJ1, CJ2, NJ Series | |||||
---|---|---|---|---|---|
Straight Multi-Pin PLC Male Plug × Straight Multi-Pin PLC Male Plug | |||||
6 1/2 | 0.31" | Black | 0° to 130° F | 0000000 | 0000000 |