Powered by the sun, these security lights function in areas that don’t have access to electricity. They’re often used to shine light on parking lots, landscaping, signs, entryways, and other outdoor spaces. They turn on when they detect motion. These lights use a built-in LED bulb that lasts longer, is more efficient, and generates less heat than alternatives.
Styles B and C are protected from low-pressure jets of liquid such as water from a garden hose.

Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Voltage | Brightness, lumens | Light Appearance | Wattage, W | Width | Height | Depth | Environmental Rating | Housing Color | Max. Sensing Distance, ft. | Batteries Included | Charging Time, hrs. | Run Time, hrs. | Mounting Hardware Included | Specifications Met | Each | |
Glass Lens | ||||||||||||||||
| 4V DC | 500 | Daylight (6000K) | 4 | 4 1/8" | 1 1/4" | 6 3/4" | IP65 | Black | 25 | Yes | 8 | 6 | Yes | CE Marked | 0000000 | 000000 |

Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Voltage | Brightness, lumens | Light Appearance | Wattage, W | Width | Height | Depth | Environmental Rating | Housing Color | Max. Sensing Distance, ft. | Batteries Included | Charging Time, hrs. | Run Time, hrs. | Mounting Hardware Included | Specifications Met | Each | |
Glass Lens | ||||||||||||||||
| 3V DC | 1,100 | Daylight (6000K) | 8.1 | 12" | 3 1/8" | 4 1/2" | IP65 | Silver | 30 | Yes | 6 | 8 | Yes | CE Marked | 0000000 | 000000 |
Add-On Heads for Emergency Backup Lights



Expand the reach of emergency backup lights. These add-on heads are often used to extend emergency lighting into stairwells, exits, and other remote areas. They’re an economical alternative to buying an additional full-sized backup light. To power them, run low-voltage wiring right from your backup light. They are adjustable, so you can angle them to direct light where it’s needed.
Select a head that matches your backup light’s output voltage. To meet UL 924, don't exceed the maximum wattage of add-on heads listed for your light. This ensures you won’t push your light's run time below 90 minutes.
Heads for use in damp locations withstand humidity and moisture. Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Overall | Head | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brightness, lumens | Max. Distance Between Lights, ft. | Wd. | Ht. | Voltage | Wattage | Material | Color | Mounting Hardware Included | Temp. Range, °F | Environment | Specifications Met | Each | ||
2 Heads | ||||||||||||||
| A | 140 | 25 | 8 5/8" | 3 3/8" | 3.6V DC | 2W | Plastic | White | Yes | 32° to 120° | Damp Location | UL 924, UL Listed, C-UL Listed | 00000000 | 000000 |
| B | 300 | 30 | 4 3/4" | 2 3/4" | 6-12V DC | 3.5W | Plastic | White | Yes | 32° to 100° | Damp Location | UL 924, UL Listed, C-UL Listed | 00000000 | 00000 |
1 Head | ||||||||||||||
| E | 150 | 15 | 4 1/2" | 2 3/4" | 6-12V DC | 1.7W | Plastic | White | Yes | 32° to 100° | Damp Location | UL 924, UL Listed, C-UL Listed | 00000000 | 00000 |
Plug-In Emergency Backup Lights

No hardwiring required—these backup lights plug into a standard outlet. They kick on when the power goes out to light the path toward exits. Their battery generates at least 90 minutes of power in compliance with UL 924 standards for backup lights. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained. Direct light where it’s needed by angling the adjustable heads.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Overall | Mounting Holes | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Plug Type | Cord Lg., ft. | Voltage | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Specifications Met | Each | |
| C | 1,100 | 125 | Manual, Automatic | 12 1/8" | 5 1/2" | 3 7/8" | Two Prong | 3 | 120V AC | 2 | Yes | 4 | 3/16" | 0° to 150° | UL 924, UL Listed | 00000000 | 0000000 |