About Calculating the Airflow Required for Air Cleaning
More
Floor-Mount Fume Exhausters
Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Use open dripproof exhausters in relatively clean, dry, well-ventilated indoor locations.
Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
Single-duct kits (sold separately) maximize airflow at one fume collection point. They include a hose, a nozzle, and two clamps.
Dual-duct kits (sold separately) create two points for fume collection, although each will have lower airflow than the one collection point of a single-duct kit. These kits include two hoses, two nozzles, four clamps, and a wye connector.
Overall | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Power, hp | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Housing Material | Base Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Each | |
Open Dripproof | |||||||||||||||
120V AC,Single Phase—Hardwire | |||||||||||||||
800 cfm @ 1/2 in. of H₂O | 65 dBC @ 15 ft. | 1/3 | 6" | 6" | 15 1/8" | 16" | 20 3/8" | Galvanized Steel | Steel | No | 1/4" | 9/32" | 4 | 000000 | 0000000 |
Totally Enclosed | |||||||||||||||
120V AC,Single Phase—Plug | |||||||||||||||
755 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 3/4 | 6" | 6" | 20 1/4" | 17" | 15 3/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
230V AC,Single Phase—Hardwire | |||||||||||||||
1,135 cfm @ 1/2 in. of H₂O | 78 dBA @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 18 1/4" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
120/230V AC,Single Phase—Hardwire | |||||||||||||||
1,045 cfm @ 1/2 in. of H₂O | 75 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 16 3/8" | 12 1/4" | 18" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 5/8" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
230/460V AC,Three Phase—Hardwire | |||||||||||||||
450 cfm @ 1/2 in. of H₂O | 64 dBA @ 15 ft. | 1/4 | 6" | 6" | 16 3/8" | 12 1/4" | 15 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
855 cfm @ 1/2 in. of H₂O | 74 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 22 7/8" | 19 1/8" | 17 1/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,135 cfm @ 1/2 in. of H₂O | 78 dBA @ 15 ft. | 3 | 6" | 6" | 22 7/8" | 19 1/8" | 19 7/8" | Black Powder-Coated Steel | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
1,615 cfm @ 1/2 in. of H₂O | 72 dBA @ 15 ft. | 2 | 8" | 8" | 21 1/2" | 14 7/8" | 18 1/4" | Aluminum | Steel | No | 3/8" | 7/16" | 4 | 00000000 | 00000000 |
Portable Fume Exhausters
In addition to using the handle to carry these exhausters, you can mount them to a wall, bench, or floor. They remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They have a flexible hose with nozzle to capture fumes at the source and rubber pads on the base to reduce vibration.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Single-duct kits (sold separately) include a hose, a nozzle, and two clamps to replace existing components.
Double-duct kits (sold separately) create two points for fume collection, although each will have lower airflow than the one collection point of a single-duct kit. These kits include two hoses, two nozzles, four clamps, and a wye connector.
Overall | Nozzle | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Power, hp | Inlet Dia. | Outlet Dia. | Ht. | Wd. | Dp. | Ht. | Wd. | Housing Material | Fasteners Included | For Screw Size | Hole Dia. | Number of Holes | Each | |
120V AC, Single Phase—Plug | ||||||||||||||||
280 cfm @ 1 1/2 in. of H₂O 330 cfm @ 1/4 in. of H₂O 345 cfm @ 0 in. of H₂O | 62 dBA @ 15 ft. | 1/2 | 4" | 4" | 18 3/4" | 17 1/2" | 16" | 4" | 8" | Steel | No | 3/8" | 7/16" | 4 | 0000000 | 000000000 |
310 cfm @ 1/4 in. of H₂O 335 cfm @ 0 in. of H₂O | 59 dBA @ 15 ft. | 1/4 | 6" | 6" | 17 7/8" | 13 3/4" | 18 1/4" | 8" | 8" | Aluminum | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
575 cfm @ 1 1/2 in. of H₂O 655 cfm @ 1/4 in. of H₂O 670 cfm @ 0 in. of H₂O | 59 dBA @ 15 ft. | 1 | 6" | 6" | 17 7/8" | 13 3/4" | 18 1/4" | 8" | 8" | Aluminum | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
730 cfm @ 1 1/2 in. of H₂O 795 cfm @ 1/4 in. of H₂O 810 cfm @ 0 in. of H₂O | 73 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 21 3/8" | 21 1/2" | 16 1/2" | 8" | 8" | Steel | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
280 cfm @ 1 1/2 in. of H₂O 330 cfm @ 1/4 in. of H₂O 345 cfm @ 0 in. of H₂O | 62 dBA @ 15 ft. | 1/2 | 4" | 4" | 18 3/4" | 17 1/2" | 16" | 4" | 8" | Steel | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
575 cfm @ 1 1/2 in. of H₂O 655 cfm @ 1/4 in. of H₂O 670 cfm @ 0 in. of H₂O | 59 dBA @ 15 ft. | 1 | 6" | 6" | 17 7/8" | 13 3/4" | 18 1/4" | 8" | 8" | Aluminum | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
730 cfm @ 1 1/2 in. of H₂O 795 cfm @ 1/4 in. of H₂O 810 cfm @ 0 in. of H₂O | 73 dBA @ 15 ft. | 1 1/2 | 6" | 6" | 21 3/8" | 21 1/2" | 16 1/2" | 8" | 8" | Steel | No | 3/8" | 7/16" | 4 | 0000000 | 00000000 |
Floor-Mount Hazardous Location Fume Exhausters
This fume exhauster has a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G locations. Use it to remove fumes, vapors, and fine dust particles from your space. It is commonly used in welding, soldering, and other operations that create fumes.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
O'all | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Power, hp | Inlet Dia. | Outlet. Dia. | Ht. | Wd. | Dp. | Housing Material | Base Material | Wheel Material | Fasteners Included | Hole Dia. | Environmental Rating | Each | |
120V AC—Hardwire | |||||||||||||||
800 cfm @ 1/2 in. of H₂O | 65 dBC @ 15 ft. | 1/3 | 6" | 6" | 15 1/8" | 18 1/4" | 20 3/8" | Galvanized Steel | Steel | Aluminum | No | 9/32" | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | 000000 | 000000000 |