McMaster-Carr logo
    Filter by
    Fuse UL Class
    With Blown Fuse Indicator
    Cartridge Fuse Type
    Number of Elements
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Rejection-Style End
    Overall Diameter
    UL File Number
    Performance
    Indicator Type
    Width
    Depth
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    12 Products

    UL Class RK5 Fuses

    Image of Product. Front orientation. Fuses. UL Class RK5 Fuses , Knife-Blade Cartridge Fuse, With Blown Fuse Indicator.
    Image of Product. Front orientation. Fuses. UL Class RK5 Fuses , Knife-Blade Cartridge Fuse, Without Blown Fuse Indicator.

    Knife-Blade Cartridge

    Fuse, With Blown Fuse

    Indicator

    Knife-Blade Cartridge

    Fuse, Without Blown

    Fuse Indicator

    Also known as dual-element fuses, these time-delay fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK5 Fuses.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    UL File
    No.
    CSA File
    No.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: FLN-R, FRN-R, TR-R
     
    1 1/16" Overall Diameter
    90RK5250V AC200,000 amp @ 250V AC5 7/8"2Knife BladeTime DelayNoYesUL Listed, CSA Certified
    E4273053787_C_0000000000000000000000
     
    Manufacturer Equivalent Fuse: FLN-R-ID, FRN-R-ID, TR-R-ID
     
    1 1/16" Overall Diameter
    90RK5250V AC, 250V DC200,000 amp @ 250V AC
    20,000 amp @ 250V DC
    5 7/8"2Knife BladeTime DelayYesYesUL Listed, CSA Certified
    E2137012636_0_000000000000000000000
     
    Manufacturer Equivalent Fuse: FLS-R, FRS-R, TRS-R
     
    1 1/8" Overall Diameter
    90RK5600V AC, 300V DC200,000 amp @ 600V AC
    20,000 amp @ 300V DC
    7 7/8"2Knife BladeTime DelayNoYesUL Listed, CSA Certified
    E4273053787_C_000000000000000000000
     
    Manufacturer Equivalent Fuse: FRS-R-ID, IDSR, TRS-R-ID
     
    1 5/16" Overall Diameter
    90RK5600V AC, 600V DC200,000 amp @ 600V AC
    20,000 amp @ 600V DC
    7 7/8"2Knife BladeTime DelayYesYesUL Listed, CSA Certified
    E2137012636_0_000000000000000000000
     

    UL Class J Time-Delay Fuses for Tight Spaces

    Image of Product. Front orientation. Fuses. UL Class J Time-Delay Fuses for Tight Spaces , Knife-Blade Cartridge Fuse, With Blown Fuse Indicator.
    Image of Product. Front orientation. Fuses. UL Class J Time-Delay Fuses for Tight Spaces , Knife-Blade Cartridge Fuse, Without Blown Fuse Indicator.

    Knife-Blade

    Cartridge Fuse,

    With Blown Fuse

    Indicator

    Knife-Blade

    Cartridge Fuse,

    Without Blown Fuse

    Indicator

    Also known as dual-element fuses, these fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. More compact than UL Class RK1 or RK5 fuses, they are suitable for tight spaces. Use with Fuse Blocks for UL Class J Fuses.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: AJT, JTD, LPJ-SP
     
    1 1/8" Overall Diameter
    90J600V AC, 300V DC300,000 amp @ 600V AC
    100,000 amp @ 300V DC
    4 5/8"2Knife BladeTime DelayNoNoUL Listed, CSA Certified
    00000000000000000000000
     
    Manufacturer Equivalent Fuse: AJT, JTD-ID, LPJ-SPI
     
    1 1/16" Overall Diameter
    90J600V AC, 400V DC200,000 amp @ 600V AC
    100,000 amp @ 400V DC
    4 5/8"2Knife BladeTime DelayYesNoUL Listed, CSA Certified
    00000000000000000
     

    UL Class T Fuses for Extra-Tight Spaces

    Image of Product. Front orientation. Fuses. UL Class T Fuses for Extra-Tight Spaces , Knife-Blade Cartridge Fuse.

    Knife-Blade

    Cartridge Fuse

    Smaller than UL Class J fuses, these fast-acting fuses can be used in extra-tight spaces such as meters, uninterruptible power supplies, and variable-speed drives. They open circuits quickly when surges are detected. Use with Fuse Blocks for UL Class T Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A6T, JJS, JLLS
     
    3/4" Overall Diameter
    90T600200,000 amp @ 600V AC2 15/16"1Knife BladeFast ActingNoNoUL Listed, CSA Certified, CE Marked
    000000000000000000000
     

    UL Class RK1 Fast-Acting Fuses

    Image of Product. Front orientation. Fuses. UL Class RK1 Fast-Acting Fuses , Knife-Blade Cartridge Fuse.

    Knife-Blade Cartridge

    Fuse

    These fuses open circuits quickly when surges are detected. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK1 Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A6K-R, KLS-R, KTS-R
     
    1 5/16" Overall Diameter
    90RK1600V AC, 300V DC200,000 amp @ 600V AC
    20,000 amp @ 300V DC
    7 7/8"1Knife BladeFast ActingNoYesUL Listed, CSA Certified
    0000000000000000000000
     

    Touch-Safe Fuses

    Image of Product. Front orientation. Fuses. Touch-Safe Fuses .
    Prevent accidental contact with electrical circuits—these fuses have an enclosed design with recessed plug-in blades. Also known as dual-element fuses, they withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that turns red when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Fuses
    DIN-Rail Mount
    Fuse Blocks
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp.
    No. of
    Elements
    Fuse Protection Type
    With Blown Fuse
    Indicator
    Certification
    Specs. Met
    Each
    Each
    Manufacturer Equivalent Fuse: TCF
    90CF600V AC, 300V DC300,000 amp @ 600V AC
    100,000 amp @ 300V DC
    3.01"1"1.26"2Time Delay, Touch SafeYesUL Listed, CSA Certified
    EN 63000, IEC 63000000000000000000000000000000
     

    Fast-Acting Lift Truck Fuses

    Image of Product. Front orientation. Fuses. Fast-Acting Lift Truck Fuses .
    These fuses open circuits quickly when surges are detected. Use them on battery-operated lift trucks.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Fuses
    Fuse Holders
    Overall
    Current,
    amp
    Voltage
    Breakthrough Current @ Voltage
    Lg.
    Wd.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    Each
    Each
    Manufacturer Equivalent Fuse: ANN, CNN
    90125V AC, 80V DC2,500 amp @ 125V AC
    2,700 amp @ 80V DC
    3 3/16"7/8"1Fast ActingYesUL Recognized Component
    00000000000000000000000000000
     
    back to top