Heat Stress Monitors
Measure temperature, humidity, and radiant heat in your work area to keep your team safe from heat-related hazards. These monitors help you avoid dangerous conditions and comply with OSHA standards for a safe work environment. They use a variety of measurements from your surroundings to calculate the heat stress index and the wet bulb globe temperature (WBGT), which tell you how hot it feels. Set a maximum wet bulb globe temperature, and an alarm will go off when heat reaches the safety limit.
These monitors have two sensors. One measures temperature, humidity, dew point, and wet globe temperature. The other measures black globe temperature, which is the effect of direct solar radiation on an exposed surface. Carry monitors with you to measure different areas, or mount to your tripod to measure conditions over time.
To maintain their accuracy, monitors should be calibrated once a year. You can calibrate the monitor yourself using humidity standards. These standards contain a known humidity, so you can adjust your monitor until it reads the humidity correctly.
Monitors that come with a calibration certificate traceable to NIST have passed a test for accuracy.
Power these monitors with the included batteries, or add a power adapter to plug them in.
Add a memory card to store your readings and export them to a computer.


Heat Stress
Monitor
Air Temp. | Black Globe Temp. | Wet Bulb Globe Temp. | Barometric Pressure | Relative Humidity | Mounting | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, °F | Accuracy, °F | Range, °F | Accuracy, °F | Range, °F | Accuracy, °F | Range | Accuracy | Range | Accuracy | Fasteners Included | No. of Holes | Hole Thread Size | Data Connection Type | Each | |
Heat Stress Monitors | |||||||||||||||
Monitors | |||||||||||||||
32° to 122° | ±1.1° | 32° to 176° | ±1.8° | 59° to 132° | ±3.6° | 8.9in. of Hg to 32.5in. of Hg | ±0.044" Hg | 0% to 100% | ±5% | No | 1 | 1/4"-20 | __ | 0000000 | 0000000 |
Monitors With NIST Certificate | |||||||||||||||
32° to 122° | ±1.1° | 32° to 176° | ±1.8° | 59° to 132° | ±3.6° | 8.9in. of Hg to 32.5in. of Hg | ±0.044" Hg | 0% to 100% | ±5% | No | 1 | 1/4"-20 | __ | 0000000 | 000000 |
Data Logging Heat Stress Monitors | |||||||||||||||
Monitors | |||||||||||||||
32° to 122° | ±1.5° | 32° to 176° | ±1.1° | 32° to 132° | ±3.6° | __ | __ | 5% to 95% | ±3% | No | 1 | 1/4"-20 | Standard SD Card | 0000000 | 000000 |
Monitors With NIST Certificate | |||||||||||||||
32° to 122° | ±1.5° | 32° to 176° | ±1.1° | 32° to 132° | ±3.6° | __ | __ | 5% to 95% | ±3% | No | 1 | 1/4"-20 | Standard SD Card | 0000000 | 000000 |

Relative Humidity | Relative Humidity Accuracy | Each | |
33%, 75% | ±1% | 0000000 | 0000000 |

Inside | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Height | Width | Depth | Weight, lbs. | Color | Material | Lock Type | Foam Type | Each | |
5 3/4" | 13" | 12" | 5 1/2" | 12" | 9 1/2" | 4 1/2 | Black | Plastic | Padlockable | Cubed | 0000000 | 000000 |

Memory Card Type | Capacity | Includes | Each | |
Standard SD, microSDHC | 16GB | Adapter | 0000000 | 000000 |
Oxygen Detectors

When your work area has too much or too little oxygen, these detectors alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the high and low alarm trigger points to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check can be performed with the press of a button.
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, % Vol. | Volume | Ht. | Wd. | Dp. | Temperature Range, °F | Batteries Included | Battery Chemistry | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | ||||||||||
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA | 00000000 | 000000 |
Batteries (Pkg. of 1) | 0000000 | Pkg. | 000000 |
Propane Detectors

An audible alarm and warning light alert you to the presence of propane. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
4,200 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Surface-Mount Multi-Gas Detectors

An audible alarm and warning light alert you to the presence of propane, methane, hydrogen, and carbon monoxide. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Detects (Trigger Point) , ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
Propane (420); Methane (5,000); Hydrogen (200); Carbon Monoxide (150) | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Early-Warning Surface-Mount Hydrogen Detectors

This detector triggers a “caution” alert when a small amount of hydrogen is detected and a second “danger” alert if levels continue to rise. When hydrogen concentration reaches 1% by volume, a yellow warning light illuminates and the first relay closes to trigger a remote exhaust fan and/or alarm. When hydrogen reaches 2%, a red warning light illuminates, an alarm sounds, and the second relay closes to activate another remote exhaust fan and/or alarm.
Use the optional remote and cable to keep an eye on the detector’s alert status from a distance. Remote has a buzzer and the same yellow and red warning lights as the detector.
Trigger Point, % Vol. | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Electrical Connection | Voltage | Fasteners Included | Mounting Hole Dia. | Each | |
1; 2 | 60 dB @ 10 ft. | 14° to 104° | 7" | 4 3/4" | 2 1/2" | Screw Terminals | 120V AC, 240V AC | No | 3/16" | 00000000 | 000000000 |
Methane Detectors

An audible alarm and warning light alert you to the presence of methane. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
10,000 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Surface-Mount Hydrogen Detectors

An audible alarm and warning light alert you to the presence of hydrogen. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
8,000 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Hydrogen Sulfide Detectors

When these detectors sense high levels of hydrogen sulfide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-100 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-200 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |
Portable Carbon Monoxide Detectors

When these detectors sense high levels of carbon monoxide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-2,000 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |
Stick-On Carbon Monoxide Indicators

Place this indicator anywhere you need to detect and warn about the presence of carbon monoxide. The circle in the center darkens when carbon monoxide is detected and returns to its normal color when exposed to fresh air. Replace indicator every 12 months. An unopened indicator has a shelf life of three years.
Trigger Point, ppm | Ht. | Wd. | Backing Type | Each | |
100 | 2 1/4" | 2 1/4" | Adhesive | 0000000 | 00000 |
Carbon Dioxide Meters

Measure and display real-time indoor ventilation quality. These meters operate with the included universal AC adapter or six AAA batteries. They have automatic baseline calibration. Transfer and view data on your computer using their USB cable and software.
Measuring Range, ppm | Temperature Range, ° F | Mount Type | Ht. | Wd. | Dp. | Power Source | Batteries Included | Number of Batteries Required | Battery Size | Electrical Connection | Voltage | Cord Lg., ft. | Each | |
0-9,999 | 32° to 122° | Portable | 8 1/4" | 2 1/2" | 1 1/2" | Battery, Electric | Yes | 6 | AAA | Plug In | 240V AC | 3 | 000000000 | 0000000 |
Portable Multi-Gas Detectors with Probe

Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL); Oxygen (0-30% Vol.); Carbon Monoxide (0-1,999 ppm); Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Portable Multi-Gas Detectors

When this detector senses high levels of combustible and toxic gases, it alerts you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL); Oxygen (0-30% Vol.); Carbon Monoxide (0-1,999 ppm); Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |