About Sound Levels
To choose an alarm or speaker that’s loud enough, first determine the decibel (dB) rating of background noise.
More
About Selecting Temperature Sensors
More
About Relative Visibility of Signal Lights
More
About Battery Disposal
More
Solar-Powered Flashing Lights
Place these lights in full sun and their batteries charge during daylight hours. Lights automatically switch on at dusk and off at dawn. They have an LED bulb for years of maintenance-free operation.
Portable lights meet IP67 and have a magnetic base for quick positioning. They can be switched on or off with the press of a button.
For technical drawings and 3-D models, click on a part number.
Continuous/Flashing/Revolving Lights
These lights can switch between continuous, flashing, or revolving. Place them wherever needed—they don't need to be wired or plugged in. The LED bulb provides years of maintenance-free operation.
Lights with a tapered handle base are good for use in traffic cones.
Lights with a magnetic base can be quickly positioned on metal surfaces.
For technical drawings and 3-D models, click on a part number.
Ht. | Dia. | Material | Environment | Batteries Included | Battery Size | No. of Batteries Required | Environmental Rating | Choose a Light Color | Each | |
LED | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Tapered Handle Base | ||||||||||
9 1/2" | 4" | Plastic | Corrosive, Damp, Dusty, Outdoor | No | D | 2 | IP62, NEMA 3 | 000000 | 000000 | |
Magnetic Base | ||||||||||
5 1/4" | 4" | Plastic | Corrosive, Damp, Dusty, Outdoor | No | D | 2 | IP62, NEMA 3 | 000000 | 00000 | |
5 1/4" | 4" | Plastic | Corrosive, Damp, Dusty, Outdoor | No | D | 2 | IP62, NEMA 3 | 000000 | 00000 |
Pocket-Size Flashing Lights
Carry these lights around with you and place them wherever needed. The LED bulb provides years of maintenance-free operation.
For technical drawings and 3-D models, click on a part number.
Ht. | Dia. | Mount Type | Material | Environment | Batteries Included | Battery Size | No. of Batteries Required | Environmental Rating | Features | Choose a Light Color | Each | |
LED | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 3/4" | 3 1/2" | Magnetic Base, Portable | Plastic | Corrosive, Damp, Dusty, Outdoor, Washdown | No | AA | 2 | IP65, NEMA 3R | Belt Clip with Strap | 000000 | 000000 |
Battery-Operated Tripod Strobe Lights
Mounted on a tripod, these lights stand higher for greater visibility than other strobe lights. Set them wherever you need a signal light—they are portable and don't need to be wired or plugged in.
For technical drawings and 3-D models, click on a part number.
Battery-Operated Strobe Lights
Set these portable lights wherever you need a signal light—they don't need to be wired or plugged in.
For technical drawings and 3-D models, click on a part number.
Electronic-Alert Stack Lights with Buzzer
Get notified about equipment issues even when you aren't around your machines. These lights connect to your computer via Ethernet, allowing you to set up email alerts when there is a problem with a machine, server, or conveyor. The buzzer can emit both continuous and pulse tones—pulse tones alternate on/off to draw greater attention than continuous tones. Lights have an LED bulb for years of maintenance-free operation.
No. of Lights | Light Color | Light Pattern | Ht. | Dia. | Volume | Volume Control | Current | Electrical Connection | Cord Lg., ft. | Material | Each | |
LED | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | Amber/Green/Red | Continuous, Flashing | 10 5/8" | 2 3/8" | 70-80 dBA @ 3.3 ft. | Adjustable | 0.23 A @ 24 V DC | Two-Prong Plug | 5 | Plastic | 0000000 | 0000000 |
Verbal Alarms
This alarm plays a recorded message when it detects someone passing within 6 1/2 feet.
O'all | Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Max. Recorded Message Lg., sec. | Material | Color | Volume Control | Control Type | Sensor Type | For Use Outdoors | Included | No. Required | Size | Mount Type | Each | |
2 1/2" | 3 3/4" | 1 1/4" | 6 | Plastic | Black | Fixed | On/Off Switch | Light Beam | No | Yes | 3 | AA | Portable | 000000 | 000000 |
Rechargeable Air Horns
When this horn runs out of air, recharge it with the included pump.
Volume | Sound Pattern | Power Source | No. of Uses | Dia. | Lg. | Ht. | Includes | Each | |
120 dBA @ 1 m 115 dBA @ 2 m 107 dBA @ 5 m 103 dBA @ 10 m | Continuous | Air | 30 | 2" | 6 1/2" | 9 1/2" | Recharge Pump | 0000000 | 000000 |
Wi-Fi Enabled Water Overflow and Freeze Detectors
Keep an eye on leaks, overflow, and temperature changes near your equipment, even when you’re offsite. These detectors connect to your Wi-Fi to send alerts about moisture, temperature, and humidity to your smartphone or tablet. Place them near tanks and tubs to watch for overflow, or near sump pumps and pipe lines to monitor temperatures and prevent frozen pipes. When water touches one of the sensors on the detector, a buzzer also goes off, alerting anyone nearby. Rated IP44, these detectors are protected from objects larger than 1mm, such as wires, and from water splashing in any direction.
Download an app onto your smart device to program temperature and humidity ranges and set up alerts. You can also create reports that show changes in temperature and humidity over time.
To extend the area they monitor, these detectors come with a detachable cable sensor that senses moisture along its entire surface. Swap in replacement cable sensors for worn sensors, or link several together to wrap around large equipment or trace the path of a pipe. Extend them up to 500 feet from detectors.
Volume | Sound Pattern | Wd. | Ht. | Dp. | Cord Lg., ft. | Material | Batteries Included | Sensor Location | Operating System Compatibility | Includes | Each | |
100 dBA @ 1 ft. | Continuous | 3" | 2" | 1 1/16" | 5 | Plastic | Yes | Bottom | Android 9.0 or Later, iOS 14 or Later | Detachable Cable Sensor, Mounting Screws | 0000000 | 000000 |
Lg., ft. | Each | |
5 | 0000000 | 000000 |
Disposable Air Horns
Toss this pocket-size air horn when it runs out of air.
Volume | Sound Pattern | Power Source | No. of Uses | Dia. | Lg. | Ht. | Each | |
115 dBA @ 3.3 ft. | Continuous | Air | 150 | 1 3/8" | 4 1/4" | 5 3/8" | 0000000 | 000000 |
Air Horns
This horn has a disposable canister that can be replaced when the propellant is gone.
Air horn storage cabinet includes a tamperproof safety-lock rod.These horns have disposable canisters that can be replaced when the propellant is gone.
Traffic-Directing Flashlights
Light the way for vehicles; the entire cone illuminates for excellent visibility. Flashlight has color filters that store inside the handle.
High-Temperature Thermocouple Probes for Air
Thick wire with ceramic insulation stands up to extreme air temperatures in forging, die casting, and heat treating.
Note: when installing probes with wire leads, the red wire is negative.
Probe | Wire | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Sensor Type | Lead Lg. | Gauge | Each | |
Iron/Nickel Probe | ||||||||||
Type J | ||||||||||
32° to 1400° | 12" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 00000 |
32° to 1400° | 12" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
32° to 1400° | 18" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 00000 |
32° to 1400° | 18" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
32° to 1400° | 24" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 00000 |
32° to 1400° | 24" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
Nickel Probe | ||||||||||
Type K | ||||||||||
32° to 2300° | 12" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 0000 |
32° to 2300° | 12" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
32° to 2300° | 18" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 00000 |
32° to 2300° | 18" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
32° to 2300° | 24" | 1/4" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 14 | 0000000 | 00000 |
32° to 2300° | 24" | 1/2" | ±0.75% | 5 | Wire Leads | Exposed | 1 1/2" | 8 | 0000000 | 00000 |
Sound Level Monitors
Continuously measure ambient sound levels. The display alerts you when levels either exceed or fall below your programmed thresholds. When operating the monitor with the included 120V AC adapter, four warning lights will also flash when a threshold is reached. Monitors have a microphone that rotates 180°. They can be surface mounted or propped up using the attached folding stand. These monitors cannot be sold to Canada due to import regulations.
You can select the frequency weighting—an electronic filter that adjusts the way the monitor measures sound. The A weighting is similar to the response of the human ear and is used by OSHA. The C weighting is suitable for measuring the sound level of machinery.
Use the calibrator (sold separately) to calibrate the monitor on a regular basis and verify that it is working properly. Remote microphone cable (sold separately) allows you to use the monitor’s microphone up to 15 ft. from the display.
Measuring Range, dB | Sound Frequency Weighting | Fasteners Included | Mounting Hole Dia. | Power Source | Electrical Connection | Batteries Included | Number of Batteries Required | Battery Size | Specifications Met | Cannot Be Sold To | Each | |
Monitors | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
30-130 | A, C | No | 1/2" | Battery, Electric | Plug In | No | 8 | AA | ANSI S1.4 | Canada | 0000000 | 0000000 |
Monitors With NIST Certificate | ||||||||||||
30-130 | A, C | No | 1/2" | Battery, Electric | Plug In | No | 8 | AA | ANSI S1.4 | Canada | 0000000 | 000000 |
Sound Level Testers
Take readings of ambient sound levels. Testers have a selectable frequency weighting—an electronic filter that adjusts the way the tester measures sound. The A weighting is similar to the response of the human ear and is used by OSHA. The C weighting is suitable for measuring the sound level of machinery.
Use the calibrator (sold separately) to calibrate the tester before each use and verify that it is working properly.
Testers that cannot be sold to Canada are restricted by import regulations.
Measuring Range, dBA | Sound Frequency Weighting | Mount Type | Ht. | Wd. | Dp. | Batteries Included | Includes | Specifications Met | Cannot Be Sold To | Each | |
Testers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
40-130 | A, C | Portable | 9" | 2 1/4" | 1 3/4" | Yes | __ | __ | Canada | 00000000 | 0000000 |
35-130 | A, C | Portable | 10" | 3" | 1 1/2" | Yes | Storage Case | ANSI S1.4 Type 2 | __ | 00000000 | 000000 |
Testers with NIST Certificate | |||||||||||
40-130 | A, C | Portable | 9" | 2 1/4" | 1 3/4" | Yes | __ | __ | Canada | 00000000 | 000000 |
35-130 | A, C | Portable | 10" | 3" | 1 1/2" | Yes | Storage Case | ANSI S1.4 Type 2 | Canada | 0000000 | 000000 |
Calibrators | 00000000 | Each | 0000000 |
Hydrogen Sulfide Detectors
When these detectors sense high levels of hydrogen sulfide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-100 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-200 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |
Oxygen Detectors
When your work area has too much or too little oxygen, these detectors alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the high and low alarm trigger points to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check can be performed with the press of a button.
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, % Vol. | Volume | Ht. | Wd. | Dp. | Temperature Range, °F | Batteries Included | Battery Chemistry | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | ||||||||||
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA | 00000000 | 000000 |
Batteries (Pkg. of 1) | 0000000 | Pkg. | 000000 |
Portable Carbon Monoxide Detectors
When these detectors sense high levels of carbon monoxide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-2,000 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |
Portable Multi-Gas Detectors
When this detector senses high levels of combustible and toxic gases, it alerts you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Portable Multi-Gas Detectors with Probe
Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |