The traditional pressure switch. These power equipment, activate controls or alarms, or kick-off other actions when they reach a set pressure. Larger than compact pressure switches, they're easier to wire. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
NEMA 1 rated switches should only be used indoors. NEMA 4 and NEMA 4X rated switches can be used in dirty and wet areas exposed to washdowns and the weather. NEMA 4X also has increased protection against corrosion, similar to 304 stainless steel. IP65 rated switches can be lightly rinsed. IP66 switches withstand washdowns.
Styles H and L have internal and external threads, so you can attach these switches to a male or female pipe connection.
Styles A-C, E-J, and L meet at least one safety standard.
Switches with a cover protect against impact and keep dust off the switch.


Style | Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp., °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Male Pipe Connection | ||||||||||||
A | 3-30 | 0.95 | 50 | 230 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | 0° to 200° | Aluminum | Air, Hydraulic Fluid (Petroleum Based), Oil, Water | __ | 0000000 | 0000000 |
A | 10-100 | 1.5 | 200 | 300 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | 0° to 200° | Aluminum | Air, Hydraulic Fluid (Petroleum Based), Oil, Water | __ | 0000000 | 000000 |
A | 30-300 | 2.5 | 400 | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | 0° to 200° | Aluminum | Air, Hydraulic Fluid (Petroleum Based), Oil, Water | __ | 0000000 | 000000 |
A | 50-500 | 3.5 | 600 | 700 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | 0° to 200° | Aluminum | Air, Hydraulic Fluid (Petroleum Based), Oil, Water | __ | 0000000 | 000000 |
1/2 NPT Male Pipe Connection | ||||||||||||
B | 0.6-14.2 | 0.65 | 15 | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Brass | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 1 | 00000000 | 000000 |
B | 3.5-82 | 4 | 90 | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Brass | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 1 | 00000000 | 000000 |
B | 29-472 | 16 | 500 | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Aluminum | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 1 | 00000000 | 000000 |








Style | Setpoint | Approximate Difference Between Setpoint and Reset Point | Max. Continuous Pressure | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp., °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Female Pipe Connection | ||||||||||||
C | 4.5-30 in. of H2O | 2.5 in. of H2O | 30 in. of H2O | 20 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 00000000 | 0000000 |
1/4 NPT Male Pipe Connection | ||||||||||||
E | 3-30 psi | 0.85 psi | 50 psi | 230 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | 0° to 200° | Aluminum | Air, Hydraulic Fluid (Petroleum Based), Oil, Water | NEMA 1 | 0000000 | 000000 |
1/2 NPT Female Pipe Connection | ||||||||||||
F | 1-20 psi | 0.55 psi | 500 psi | 1,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 1 A @ 30 V DC 30 mA @ 125 V DC | -70° to 300° | 316L Stainless Steel | Air, Hydraulic Fluid, Oil, Water | NEMA 4X | 0000000 | 000000 |
1/2 NPT Male Pipe Connection | ||||||||||||
G | 0.6-14.2 psi | 0.65 psi | 15 psi | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Brass | Air, Hydraulic Fluid, Nitrogen, Oil, Water | IP65; NEMA 4 | 00000000 | 000000 |
G | 3.5-82 psi | 4 psi | 90 psi | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Brass | Air, Hydraulic Fluid, Nitrogen, Oil, Water | IP65; NEMA 4 | 00000000 | 000000 |
G | 11-230 psi | 10 psi | 250 psi | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Brass | Air, Hydraulic Fluid, Nitrogen, Oil, Water | IP65; NEMA 4 | 0000000 | 000000 |
G | 29-472 psi | 16 psi | 500 psi | 1,000 | ±2% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -20° to 165° | Aluminum | Air, Hydraulic Fluid, Nitrogen, Oil, Water | IP65; NEMA 4 | 0000000 | 000000 |
1/4 NPT Female Pipe Connection and 1/2 NPT Male Pipe Connection | ||||||||||||
H | 450-3,000 psi | 220 psi | 3,000 psi | 12,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
Wire Leads | ||||||||||||
1/4 NPT Female Pipe Connection | ||||||||||||
J | 4.5-30 psi | 1 psi | 30 psi | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
J | 9-60 psi | 3 psi | 60 psi | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
J | 15-100 psi | 4.5 psi | 100 psi | 1,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
J | 30-200 psi | 12 psi | 200 psi | 1,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
J | 60-400 psi | 20 psi | 400 psi | 2,400 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
K | 0.068-1.6 psi | 0.04 psi | 1.7 psi | 3 | ±0.5% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -65° to 165° | 304 Stainless Steel | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 4 | 0000000 | 000000 |
K | 0.18-2.8 psi | 0.11 psi | 3 psi | 10 | ±0.5% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -65° to 165° | 304 Stainless Steel | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 4 | 0000000 | 000000 |
K | 0.66-17 psi | 0.19 psi | 18 psi | 60 | ±0.5% | 10 A @ 125 V AC 10 A @ 250 V AC 3 A @ 480 V AC | -65° to 165° | 304 Stainless Steel | Air, Hydraulic Fluid, Nitrogen, Oil, Water | NEMA 4 | 0000000 | 000000 |
1/4 NPT Female Pipe Connection and 1/2 NPT Male Pipe Connection | ||||||||||||
L | 150-1,000 psi | 98 psi | 1,000 psi | 12,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
L | 450-3,000 psi | 220 psi | 3,000 psi | 12,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, Water | IP66; NEMA 4X | 0000000 | 000000 |
Dual-Setpoint Pressure Switches

Trigger two different automated processes, each with their own set pressure. These switches could, for example, turn one pump on to empty a tank when the pressure gets too high and another to fill the tank when the pressure drops too low. Or use them to trigger an alarm before turning off a pump. These have two single pole, double throw (SPDT) switches and can switch each circuit from off to on (normally open) or on to off (normally closed).
NEMA 4X and IP66 rated, these switches seal out dust and water from washdowns and weather, and they resist corrosion. They are UL listed, CSA certified, and CE marked to meet American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Setpoint | Approximate Diff. Between Setpoint and Reset Point | Max. Continuous Pressure | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temperature Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Female Pipe Connection | |||||||||||
4.5 in. of H2O-30 in. of H2O | 4.5 in. of H2O | 30 in. of H2O | 20 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 00000000 | 0000000 |
1.4 psi-2.1 psi | 1.5 psi | 15 psi | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
1.4 psi-5 psi | 3 psi | 30 psi | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
3 psi-7 psi | 5 psi | 60 psi | 500 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
7 psi-12 psi | 9.5 psi | 100 psi | 1,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
10 psi-23 psi | 16 psi | 200 psi | 1,000 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
22 psi-42 psi | 32 psi | 400 psi | 2,400 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
22 psi-70 psi | 46 psi | 600 psi | 2,400 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 500 mA @ 125 V DC 250 mA @ 250 V DC | 0° to 150° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66; NEMA 4X | 0000000 | 000000 |
Compact Pressure Switches
With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces. They’re often built into pumps and hydraulic systems with limited space in order to turn equipment on and off, activate automated controls, or signal alarms when they reach a set pressure. These switches are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They also meet at least one American, Canadian, or European safety standard.
Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand. NEMA 1 rated switches protect against corrosion. NEMA 6 and IP67 rated switches seal out dust and water from washdowns and temporary submersion.
For technical drawings and 3-D models, click on a part number.

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
1/8 NPT Male Pipe Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
External Setpoint Adjustment | |||||||||||
100-800 | 60 | 5,000 | 6,000 | ±5% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 0000000 |
500-3,000 | 135 | 3,000 | 4,000 | ±6% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 000000 |
600-5,000 | 290 | 5,000 | 6,000 | ±6% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 000000 |
1/4 NPT Male Pipe Connection | |||||||||||
External Setpoint Adjustment | |||||||||||
250-450 | 90 | 600 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
430-1,450 | 220 | 1,700 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
1,650-3,900 | 425 | 4,400 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
4,000-6,700 | 600 | 7,500 | 12,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
1/8 NPT Male Pipe Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
External Setpoint Adjustment | |||||||||||
100-800 | 60 | 5,000 | 6,000 | ±5% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 0000000 |
500-3,000 | 135 | 3,000 | 4,000 | ±6% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 000000 |
600-5,000 | 290 | 5,000 | 6,000 | ±6% | 5 A @ 250 V AC 3 A @ 28 V DC | -65° to 255° | 316 Stainless Steel | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | NEMA 1 | 0000000 | 000000 |
1/4 NPT Male Pipe Connection | |||||||||||
External Setpoint Adjustment | |||||||||||
250-450 | 90 | 600 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
430-1,450 | 220 | 1,700 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
1,650-3,900 | 425 | 4,400 | 7,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |
4,000-6,700 | 600 | 7,500 | 12,000 | ±2% | 5 A @ 125 V AC 5 A @ 250 V AC | -40° to 165° | Brass | Air, Hydraulic Fluid, Oil, Water | NEMA 1 | 00000000 | 000000 |

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
1/4 NPT Male Pipe Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
External Setpoint Adjustment | |||||||||||
6-30 | 3 | 800 | 1,000 | ±5% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 0000000 |
8-60 | 6 | 800 | 1,000 | ±5% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
10-100 | 9 | 800 | 1,000 | ±5% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
20-200 | 16 | 800 | 1,000 | ±5% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
50-500 | 60 | 5,000 | 8,000 | ±2% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
100-1,000 | 85 | 5,000 | 8,000 | ±2% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
200-2,000 | 165 | 5,000 | 8,000 | ±2% | 3 A @ 125 V AC 2 A @ 30 V DC | -40° to 212° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, Water | IP67; NEMA 6 | 00000000 | 000000 |
Adjustable-Reset Pressure Switches
Choose when these switches reset to control the pressure range between when they activate and deactivate, commonly referred to as deadband and differential. You can adjust their reset point anywhere along the setpoint range. When they reach the set pressure, these switches power equipment, signal controls, or trigger alarms. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). UL listed and CSA certified, all meet American and Canadian safety standards. Those that are CE marked meet European safety standards.
Switches with an on/off indicator tell you the status of your equipment, letting you monitor your equipment even when it’s out of sight.
All protect against some corrosion. NEMA 1 rated switches should only be used indoors.

Setpoint, psi | Approximate Difference Between Setpoint and Reset Point | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Specifications Met | Each | |
Screw Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Male Pipe Connection | ||||||||||||
1/8-15 | Adjustable | 15 | 15 | ±1% | 10 A @ 120 V AC 10 A @ 240 V AC | 35° to 180° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | NEMA 1 | UL Listed, CSA Certified | 0000000 | 0000000 |
2-60 | Adjustable | 60 | 60 | ±1% | 10 A @ 120 V AC 10 A @ 240 V AC | 35° to 180° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 |
Differential Pressure Switches for Air


Often used with ovens, dryers, and HVAC systems, these switches detect small differences in air pressure to indicate a filter is clogged or help you maintain a certain air pressure. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet at least one safety standard.
When measuring pressure in ductwork, pair them with a static pressure probe.
NEMA 13 rated switches can be used in dirty, damp, and oily areas. Switches rated IP54 protect against dust and splashing water.
Setpoint, in. of H2O | Approximate Difference Between Setpoint and Reset Point, in. of H2O | Max. Input Pressure | Accuracy | Max. Switching Current | Process Temp. Range, ° F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/4" Barbed Male Tube Connection | ||||||||||
0.08-1.2 | 0.05 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 000000 |
0.12-1.6 | 0.08 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 00000 |
0.2-2 | 0.09 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 00000 |
0.8-4 | 0.45 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 00000 |
2-10 | 0.7 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 00000 |
4-20 | 1.2 | 40 in. of H2O | ±1% | 1.5 A @ 120 V AC 400 mA @ 250 V AC | 0° to 185° | Nylon Plastic | Air | IP54, NEMA 13 | 0000000 | 00000 |
1/8 NPT Female Pipe Connection | ||||||||||
0.07-0.15 | 0.04 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
0.15-0.55 | 0.1 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
0.4-1.6 | 0.16 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
1.4-5.5 | 0.3 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
3-11.75 | 0.4 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
4-20 | 0.5 | 45 in. of H2O | ±3% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -30° to 180° | Aluminum | Air | __ | 00000000 | 00000 |
5-44 | 0.83 | 10 psi | ±2% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -20° to 180° | Steel | Air | __ | 00000000 | 000000 |
9-85 | 2.15 | 10 psi | ±2% | 15 A @ 120 V AC 15 A @ 240 V AC 15 A @ 480 V AC | -20° to 180° | Steel | Air | __ | 00000000 | 000000 |
Hazardous Location Differential Pressure Switches for Air

With an explosionproof enclosure that meets NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL and CSA for use where explosive gas or dust may be present. Often used with ovens, dryers, and HVAC systems, they can indicate a filter is clogged or help maintain a certain air pressure. These switches turn equipment on and off, activate automated controls, or signal alarms when the differential pressure reaches your setpoint. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
In addition to being UL listed and CSA certified, these switches are CE marked and FM approved, so they also meet European safety standards. They also are IP and NEMA rated for use outdoors and protect against dust and splashing water.
When measuring pressure in ductwork, pair them with a static pressure probe.
For technical drawings and 3-D models, click on a part number.
Setpoint Range | Approximate Difference Between Setpoint and Reset Point | Max. Input Pressure | Accuracy | Max. Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1/8 NPT Female Pipe Connection | ||||||||||
0.07-0.15 in. of H2O | 0.13 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 0000000 |
0.15-0.5 in. of H2O | 0.05 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
0.4-1.6 in. of H2O | 0.18 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
1.4-5.5 in. of H2O | 0.35 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
3-11 in. of H2O | 0.45 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
4-20 in. of H2O | 0.5 in. of H2O | 45 in. of H2O | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
0.5-2 psi | 0.3 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | -40° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
1.5-8 psi | 1 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
3-15 psi | 0.9 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
4-25 psi | 0.7 psi | 35 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
15-50 psi | 1.25 psi | 70 psi | ±2% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 0° to 140° | Aluminum | Air | IP54; NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Division 1 Groups E, F ,G; NEMA 3; NEMA 7; NEMA 9 | 0000000 | 000000 |
Pressure and Vacuum Switches

Because these switches work with both positive and negative (vacuum) pressures, you can use them in applications that span both. For example, these switches can turn on a light when they reach the setpoint to indicate which pressure is flowing. They’re also often used to trigger automated controls and activate alarms. These switches are single pole, double throw (SPDT) and can either turn one circuit from off to on (normally open) or from on to off (normally closed).
NEMA 4X and IP66 rated, they’re dust tight and protected from washdowns and corrosion. All are UL and C-UL listed, CSA and CSA-US certified, and CE marked, so they meet U.S., Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Setpoint | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Vacuum, in. of Hg | Approximate Difference Between Setpoint and Reset Point, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Accuracy | Maximum Switching Current | Process Temp. Range, °F | Connection Material | For Use With | Environmental Rating | Each | |
Screw Terminals | ||||||||||||
1/4 NPT Female Pipe Connection | ||||||||||||
0-15 | 30-0 | 1.5 | 15 | 250 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 0000000 | 0000000 |
0-30 | 30-0 | 2.25 | 30 | 250 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 0000000 | 000000 |
0-60 | 30-0 | 4 | 60 | 250 | ±1% | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC 6 A @ 30 V DC 500 mA @ 125 V DC 250 mA @ 250 V DC | 20° to 300° | 316 Stainless Steel | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water | IP66, NEMA 4X | 0000000 | 000000 |
Air-Pressure-Actuated HVAC Switches

Often used to detect clogged air filters and iced air conditioner coils, these switches sense small changes in pressure between two points in your duct.
Setpoint, in. of H2O | Accuracy, in. of H2O | Temperature Range, °F | Current | Electrical Connection Type | Switch Type | Max. Pressure, psi | Low Pressure Side Connection | High Pressure Side Inside Connection | High Pressure Side Outside Connection | Each | |
Diaphragm Sensor | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
0.05-5 | 0.025 | -40° to 165° | 2.9 A @ 240 V AC 5.8 A @ 120 V AC | Hardwire | SPDT | 1 | 1/8 NPT Female | 1/8 NPT Female | 1/2 NPSM | 000000 | 0000000 |
0.05-5 | 0.04 | -40° to 165° | 4.9 A @ 240 V AC 9.8 A @ 120 V AC | Hardwire | SPDT | 1 | 1/8 NPT Female | 1/8 NPT Female | 1/2 NPSM | 000000 | 000000 |