Solid State Screw Terminal Relays



Covered Terminals
and LED Indicator



With no moving parts, these solid-state relays are fast switching and require less maintenance, last longer, and are quieter than mechanical switches.
IP20 rated relays prevent fingers and other objects from touching live circuits.
Heat sinks disperse heat to increase the relay’s current rating. Mount them to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces. Before mounting one-circuit relays, silicone compound should be applied between the heat sink and relay. Silicone is sold separately for 75A and 90A one-circuit relays. Two-circuit relays don’t require silicone for mounting.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current | Heat Sinks | Silicone Compounds | |||||||||||||
Number of Terminals | Input Voltage | Without Heat Sink | With Heat Sink | Switching Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Environmental Rating | Each | Each | Each | |||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
Relays | |||||||||||||||
4 | 5V DC, 6V DC, 12V DC, 24V DC, 48V DC, 60V DC | 2A | 3A | 60V DC | 60V DC | 2.3" | 1.8" | 0.8" | __ | 0000000 | 000000 | 0000000 | 0000000 | 000000 | 00 |
4 | 5V DC, 6V DC, 12V DC, 24V DC, 48V DC, 60V DC | 2A | 5A | 60V DC | 60V DC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
Relays with High-Starting-Current Protection | |||||||||||||||
4 | 70V AC, 120V AC, 140V AC | 7.5A | 25A | 300V AC | 300V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
4 | 85V AC, 120V AC, 240V AC, 280V AC | 7A | 25A | 120V AC | 140V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 85V AC, 120V AC, 240V AC, 280V AC | 7A | 25A | 240V AC | 280V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 85V AC, 120V AC, 240V AC, 280V AC | 11A | 45A | 240V AC | 280V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 12V AC, 24V AC, 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7.5A | 25A | 300V AC | 300V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7A | 25A | 120V AC | 140V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7A | 25A | 240V AC | 280V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 11A | 45A | 120V AC | 140V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 11A | 45A | 240V AC | 280V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
Relays with High-Starting-Current Protection and Covered Terminals | |||||||||||||||
4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 2.5A | 25A | 240V AC | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC | 2.5A | 50A | 240V AC | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 2.5A | 25A | 240V AC | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 2.5A | 50A | 240V AC | 265V AC | 2.3" | 1.8" | 1.1" | IP20 | 0000000 | 00000 | 0000000 | 00000 | 000000 | 00 |
Relays with High-Starting-Current Protection and Covered Terminals and LED Indicator | |||||||||||||||
4 | 120V AC, 240V AC | 7A | 75A | 240V AC | 240V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 00000000 | 000000 |
4 | 120V AC, 240V AC | 7A | 90A | 240V AC | 240V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 00000000 | 00000 |
Relays with High-Starting-Current Protection and LED Indicator | |||||||||||||||
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7A | 25A | 240V AC | 280V AC | 2.3" | 1.8" | 1" | __ | 0000000 | 00000 | 0000000 | 000000 | 000000 | 00 |
1 Circuit Controlled with 1 On (Normally Closed)—SPST-NC | |||||||||||||||
Relays with High-Starting-Current Protection | |||||||||||||||
4 | 70V AC, 120V AC, 140V AC | 7.5A | 25A | 300V AC | 300V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
4 | 12V AC, 24V AC, 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7.5A | 25A | 300V AC | 300V AC | 2.3" | 1.8" | 1.1" | __ | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
2 Circuit Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||||||
Relays with High-Starting-Current Protection and Covered Terminals and LED Indicator | |||||||||||||||
6 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 5A | 50A | 600V AC | 660V AC | 2.3" | 1.8" | 1.3" | IP20 | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
6 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 7.5A | 75A | 600V AC | 660V AC | 2.3" | 1.8" | 1.3" | IP20 | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
2 Circuit Controlled with 2 Off (Normally Open)—SPST-NO | |||||||||||||||
Relays with High-Starting-Current Protection and Covered Terminals and LED Indicator | |||||||||||||||
8 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 5A | 50A | 600V AC | 660V AC | 2.3" | 1.8" | 1.3" | IP20 | 0000000 | 000000 | 0000000 | 000000 | 000000 | 00 |
Open-Style Relays



Use these relays with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Optional covers protect contacts from dust and dirt.
Relays | Optional Covers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
4 | 24V AC | 396 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 000000 | 0000000 | 000000 |
4 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
4 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
5 | 24V AC | 396 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
5 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
6 | 24V AC | 396 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
6 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 2.5" | 2.5" | 2.2" | 0000000 | 00000 | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 24V AC | 396 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 120V AC | 79 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 240V AC | 40 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 12V DC | 167 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
8 | 24V DC | 83 | 30 A @ 120 V AC/24 V DC | 132V AC/26V DC | 1 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.3" | 2.5" | 2.4" | 0000000 | 00000 | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open) or 4 On (Normally Closed)—4PDT | ||||||||||||
14 | 120V AC | 116 | 35 A @ 120 V AC 20 A @ 24 V DC | 120V AC | 1 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3.4" | 2.7" | 2.7" | 0000000 | 000000 | 0000000 | 00000 |
DIN-Rail Mount Solid State Relays


Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, switch faster, and are quieter. They mount on 35 mm DIN rail (also known as DIN 3) for fast installation. IP20 rated, their terminals are recessed, so they prevent fingers and other objects from touching live circuits.
Relays with an integrated heat sink disperse heat to increase the relay’s current rating.
Relays with an integrated fan are best for applications that generate more heat. The fan automatically turns on to provide additional cooling. When the temperature exceeds 176° F, an alarm sends a signal to an external device, such as a controller or indicating light.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Single Phase | |||||||||||
4 | 90V AC, 120V AC, 240V AC, 280V AC | 12 | 4.5 A @ 24 V AC (Full Load) 8 A @ 24 V AC (Resistive Load) 10 A @ 24 V AC | 600V AC | __ | 3.5" | 0.7" | 2.6" | Integrated Heat Sink, LED Indicator | 0000000 | 0000000 |
4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 13 | 20 A @ 240 V AC (Full Load) | 264V AC | 1/3 hp @ 115 V AC 1 hp @ 230 V AC | 4.3" | 0.7" | 4.1" | Integrated Heat Sink, LED Indicator | 0000000 | 00000 |
4 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 13 | 30 A @ 230 V AC (Full Load) | 264V AC | 3/4 hp @ 115 V AC 2 hp @ 230 V AC | 4.2" | 0.9" | 5.4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 11 | 20 A @ 240 V AC (Full Load) | 264V AC | 1/3 hp @ 115 V AC 1 hp @ 230 V AC | 4.3" | 0.7" | 4.1" | Integrated Heat Sink, LED Indicator | 0000000 | 00000 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 11 | 30 A @ 230 V AC (Full Load) | 264V AC | 3/4 hp @ 115 V AC 2 hp @ 230.000 V AC | 4.2" | 0.9" | 5.4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
4 | 3V DC, 6V DC, 12V DC, 24V DC, 30V DC | 30 | 4.5 A @ 24 V AC (Full Load) 8 A @ 24 V AC (Resistive Load) 10 A @ 24 V AC | 600V AC | __ | 3.5" | 0.7" | 2.6" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
4 | 4V DC, 6V DC, 12V DC, 24V DC, 30V DC | 12 | 4.5 A @ 24 V AC (Full Load) 8 A @ 24 V AC (Resistive Load) 8 A @ 3 V DC | 150V DC | __ | 3.5" | 0.7" | 2.6" | Integrated Heat Sink, LED Indicator | 0000000 | 00000 |
4 | 24V DC | 18 | 15 A @ 24 V DC (Resistive Load) | 32V DC | __ | 3.5" | 0.7" | 2.4" | LED Indicator | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
Two Phase | |||||||||||
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.3" | 2.1" | 4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 24V AC, 120V AC, 208V AC, 240V AC, 277V AC, 24V DC, 48V DC, 60V DC, 120V DC | 2 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.3" | 2.1" | 4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 220 V AC (Full Load) | 242V AC | 1 1/2 hp @ 115 V AC 3 hp @ 230 V AC | 4.3" | 2.1" | 4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
6 | 5V DC, 6V DC, 12V DC, 24V DC, 30V DC | 10 | 25 A @ 600 V AC (Full Load) | 660V AC | 5 hp @ 230 V AC 10 hp @ 480 V AC | 4.3" | 2.1" | 4" | Integrated Heat Sink, LED Indicator | 0000000 | 000000 |
Spade-Terminal Relays

Using a low-current signal, these relays are often used to control small motors and heaters. These relays attach to quick-disconnect terminals.
Surface-mount relays have a slot on the flange for mounting them to flat surfaces.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Maximum Switching Voltage | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Surface Mount | ||||||||||
4 | 24V AC | 71 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 000000 |
4 | 120V AC | 20 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
4 | 240V AC | 10 | 30 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||
Surface Mount | ||||||||||
6 | 24V AC | 71 | 25 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 120V AC | 20 | 25 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 240V AC | 10 | 25 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 12V DC | 158 | 25 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
6 | 24V DC | 79 | 25 A @ 240 V AC | 250V AC | 1.3" | 2.7" | 1.9" | 0.25" | 0000000 | 00000 |
Screw Terminal Relays

Use the screw terminals to hardwire these relays. The built-in enclosure protects contacts from dust and dirt. These relays accept voltage drops up to 50% of the rated voltage without switching. They’re often used with industrial automation systems, security and emergency lighting, and small motors. Also known as power relays.
Switching Current @ Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
4 Circuits Controlled with 2 Off (Normally Open) and 2 On (Normally Closed)—4PST-2NO/2NC | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 000000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
4 Circuits Controlled with 3 Off (Normally Open) and 1 On (Normally Closed)—4PST-3NO/1NC | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | 8 A @ 240 V AC/24 V DC | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||
10 | 120V AC | 22 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 240V AC | 11 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |
10 | 24V DC | 83 | 25 A @ 240 V AC/24 V DC | __ | 250V AC | 1 1/2 hp @ 120 V AC 3 hp @ 240 V AC 3 hp @ 277 V AC | 1.4" | 2" | 2.5" | 0000000 | 00000 |