Filter by
System of Measurement
Maximum Temperature
Minimum Temperature
Material
Electrical Connection
Enclosure Rating
Maximum Distance
Thermometer Type
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
DFARS Specialty Metals
Export Control Classification Number (ECCN)
RoHS
Output Analog Signal
Housing Thread Pitch
Housing Thread Size
Maximum Temperature Measurement
Minimum Temperature Measurement
About Temperature Sensors
Choose between RTDs and thermocouples based on your application's maximum temperature, duration, and environment.
Noncontact Temperature Sensors for Tanks
For Tank | M12 Male Electrical Connection | Mounting Holes | Mounting Slots | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wall Thk. | Min. Dia., ft. | Temp. Measurement Range, ° F | Accuracy | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Operating Temp. Range, ° F | Mounting Fasteners Included | No. of | Dia. | No. of | Wd. | Enclosure Rating | Electrical Connection Gender | Each | |||
4 mA to 20 mA Output Signal | ||||||||||||||||||||||
| 1/8" | 2 | -4 to 212 | ±0.9° F | 5 | 4 3/8" | 2 5/8" | 1 5/8" | 8 | A | Nylon | 32 to 100 | Yes | 1 | 5/16" | 1 | 5/16" | IP67 | Male | 5753N11 | 0000000 | ||
Pocket Infrared Thermometers
Batteries | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Thermometer Features | Enclosure Rating | Certification | Included | Size | No. of | Each | |||
For Dark, Light, and Shiny Surfaces | ||||||||||||||||||||
Adjustable Emissivity | ||||||||||||||||||||
| E | 32° F to 932° F/0° C to 500° C | 1° F/1° C | ±3.6° F/±2° C | 15 | 0.7 to 0.95 | 1 | 6 5/16" | 1 11/16" | 1 11/16" | Plastic | Automatic Shutoff, Laser Sight | IP67 | CE Marked | Yes | 9V | 1 | 6614T31 | 0000000 | ||
Clamp-On Noncontact Temperature Sensors for Pipe
For Pipe | M12 Male Electrical Connection | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Schedule | Temp. Measurement Range, ° F | Accuracy | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Operating Temp. Range, ° F | Enclosure Rating | Electrical Connection Gender | Each | |||
4 mA to 20 mA Output Signal | |||||||||||||||||
For Metal Pipes | |||||||||||||||||
| 1 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N11 | 0000000 | ||
| 2 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N13 | 000000 | ||
| 2 1/2 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N15 | 000000 | ||
| 3 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N16 | 000000 | ||
| 4 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N17 | 000000 | ||
For Plastic Pipes | |||||||||||||||||
| 1 | 40 | -4 to 212 | ±2.7° F | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N12 | 000000 | ||
| 2 | 40 | -4 to 212 | ±2.7° F | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N14 | 000000 | ||