McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    Wire Construction
    Industrial Info Compare
    Outer Jacket Material
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Inner Insulation Material
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    63 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Specs. Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    222/2
    0.11"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1100000000000000000000000000000
    22
    422/4
    0.13"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    UL Listed, C-UL Listed
    8280T1200000000000000000000000000
    22
    622/6
    0.16"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1300000000000000000000000000
    22
    822/8
    0.19"PVC
    WhitePVC
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T1400000000000000000000000000
    22
    1222/12
    0.23"PVC
    WhitePVC
    Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T1500000000000000000000000000
    18
    218/2
    0.14"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1600000000000000000000000000
    18
    318/3
    0.15"PVC
    WhitePVC
    Black, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T170000000000000000000000000
    18
    418/4
    0.17"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1800000000000000000000000000
    18
    618/6
    0.21"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1900000000000000000000000000
    16
    216/2
    0.16"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T2100000000000000000000000000
    16
    416/4
    0.2"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T22000000000000000000000000000
    14
    214/2
    0.21"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T2300000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    222/2
    0.14"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1100000000000000000000000000000
    22
    422/4
    0.15"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1200000000000000000000000000
    22
    822/8
    0.19"PVC
    WhitePVC
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1300000000000000000000000000
    18
    218/2
    0.16"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1400000000000000000000000000
    18
    318/3
    0.19"PVC
    WhitePVC
    Black, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1500000000000000000000000000
    18
    418/4
    0.2"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1600000000000000000000000000
    18
    618/6
    0.23"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T17000000000000000000000000000
    16
    216/2
    0.19"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1800000000000000000000000000
    16
    416/4
    0.22"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T19000000000000000000000000000
    14
    214/2
    0.22"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T2100000000000000000000000000
     

    Duct-Rated Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Ethernet Cable , Unshielded.
    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Ethernet Cable , Shielded.

    Unshielded

    Shielded

    Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Max. Temp.,
    ° F
    OD
    Cable
    Designation
    Outer Jacket
    Material
    Material
    Color
    Choose an Outer Jacket Color
    Choose a Length, ft.
    1-499
    500-Up
    Unshielded Solid Wire
    5e
    35024
    824/8
    1650.21"CMP
    PVC
    FEP/Polyolefin BlendBlue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Blue, White25, 50, 100, 500, 1,0007365K290000000000
    6
    35023
    823/8
    1650.23"CMP
    PVC
    FEP/Polyolefin BlendBlue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Black, Blue, Gray, Green, White, Yellow25, 50, 100, 500, 1,0008245K4100000000
     
    Shielded Solid Wire with Uninsulated Ground Wire
    6
    25023
    823/8
    1400.29"CMP
    PVC
    FEP
    Blue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Gray25, 50, 100, 500, 1,0004265T300000000
     

    Outdoor Lead Wire

    The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
    600V AC/600V DC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 600V AC, 600V DC.
    SC Cable—SC wire is a good choice for temporary setups powering outdoor lights, equipment, generators, and power distribution boxes, since its thick insulation makes it easy to move and reuse. Commonly found at outdoor events, it’s also known as stage cable.
    UL 2556 FT5—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT5 wire is suspended horizontally during testing.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Stranded Wire
    6
    273/30105 amp @ 86° F0.47"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T170000000000
    4
    429/30140 amp @ 86° F0.51"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1600000000
    2
    676/30190 amp @ 86° F0.58"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1500000000
    1/0
    1,042/30
    260 amp @ 86° F0.6"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1400000000
    2/0
    1,316/30
    300 amp @ 86° F0.65"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T13000000000
    4/0
    2,062/30
    405 amp @ 86° F0.77"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T110000000000
     
    2,000V AC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 2,000V AC.
    DLO Cable—DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An outer layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
    UL 2556 FT4—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
    AWG
    Current @
    Temp.
    OD
    Max. Temp.,
    ° F
    Outer Jacket
    Material
    Inner Insulation
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire
    12
    Not Rated0.21"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T24000000000000000000000000
    8
    55 amp @ 86° F0.33"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T260000000000000000000000
    6
    75 amp @ 86° F0.37"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T270000000000000000000000
    4
    95 amp @ 86° F0.44"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2800000000000000000000000
    2
    130 amp @ 86° F0.5"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2900000000000000000000000
    1/0
    170 amp @ 86° F0.65"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T31000000000000000000000000
    2/0
    195 amp @ 86° F0.69"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3200000000000000000000000000
    4/0
    260 amp @ 86° F0.82"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3300000000000000000000000000
     

    VFD Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power Wire— Stranded with PVC Outer Jacket
    Image of Product. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with PVC Outer Jacket.
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with PVC Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power wires sends electricity to run a motor.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    MSHA Accepted—MSHA-accepted cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
    Power
    Wire
    Inner
    Insulation
    Per Ft.
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    Double Shielded—1,000V AC/1,500V DC
    418
    18/4
    7 amp @ 86° F0.39"BlackNylon, PVC
    Black-40 to 220WTTC
    UL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T280000000000
    416
    16/4
    10 amp @ 86° F0.46"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    Uninsulated Ground WireUL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T2700000000
     

    Flame-Resistant Welding Cable

    Image of Product. Front orientation. Welding Cable. Flame-Resistant Welding Cable.
    Image of Specification. Front orientation. Contains Border. Welding Cable. Flame-Resistant Welding Cable, Flexible, Stranded Wire Class M.

    This cable meets Mine Safety and Health Administration (MSHA) standards for flame resistance. The insulation resists abrasion and chemicals.
    Stranded Wire Class M—Class M cable is more flexible and durable than Class K cable.
    Outer
    Jacket
    Per Ft.
    AWG
    Stranded
    Wire Class
    Wire Strand
    Count
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    600V AC/600V DC
     
    Flexible
    6
    M660/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A180000000000
    4
    M1,045/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A1100000000
    2
    M1,634/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A12000000000
    1/0
    M2,597/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A140000000000
    2/0
    M3,300/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A150000000000
    3/0
    M4,214/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A160000000000
    4/0
    M5,225/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A170000000000
     

    Access Control Cable

    Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Access Control Cable.
    Outer
    Jacket
    Inner
    Insulation
    Security Cable
    Use
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Flammability Rating
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    300V AC/300V DC
    Card Reader
    Door Contact
    Exit Sign
    Lock
    22
    22
    22
    18
    6
    2
    4
    4
    22/6
    22/2
    22/4
    18/4
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    4 amp @ 86° F
    0.46"PVC
    YellowPVC
    Blue, Gray, Orange, White32 to 165CMP
    CSA C22.2 No. 0.3 FT65846N150000000000000000000000000000
     

    Duct-Rated Ethernet Cords

    Also known as plenum-rated cords, these CMP ethernet cords have flame-resistant, low-smoke insulation and can be used without conduit in ductwork and above a drop ceiling. The RJ45 plugs on each end connect to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). Not only do these cords transmit data, but they also power devices that are Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems.
    Straight RJ45 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Duct-Rated Ethernet Cords.
    Lg.,
    ft.
    Transmission
    Freq., MHz
    AWG
    Cord
    OD
    Cable
    Designation
    Shielding
    Temp. Range,
    ° F
    Color
    Each
     
    Category 6 Ethernet Cable
    1555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N11000000
    2555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N1200000
     

    Duct-Rated Oil-Resistant Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Oil-Resistant Ethernet Cable , Unshielded.

    Unshielded

    Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Max. Temp.,
    ° F
    OD
    Cable
    Designation
    Material
    Color
    Material
    Color
    Choose a Length, ft.
    1-99
    100-Up
    Unshielded Solid Wire
    5e
    35024
    824/8
    3000.19"CMP
    FEP
    BlackFEP
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    25, 50, 100, 300, 5009284T50000000000
    6
    35023
    823/8
    3000.21"CMP
    FEP
    BlackFEP
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    25, 50, 100, 300, 5009284T900000000
     

    Duct-Rated HDMI Video Cords

    Image of Product. Front orientation. HDMI Cords. Duct-Rated HDMI Video Cords.
    Run high-definition signals through duct, above drop ceilings, and below raised floors without using conduit. These cords are plenum rated, so their insulation resists fire and doesn’t produce smoke. Connect these cords to monitors, TVs, and projectors. Each end has both a standard HDMI plug and a micro-HDMI socket, so you can connect multiple devices to the cord at once. The plugs are gold plated to resist corrosion and maintain signals over time.
    Note: These cords only transmit signals in one direction. Ends are labeled “Source” or “Display” to help you install the cord.
    Standard HDMI Male Plug and Micro HDMI Female Socket × Standard HDMI Male Plug and Micro HDMI Female Socket
    Lg.,
    ft.
    Cord
    OD
    Cable
    Designation
    Color
    Each
    Flexible
    200.21"CMP
    Black5593N110000000
    300.21"CMP
    Black5593N12000000
    600.21"CMP
    Black5593N13000000
    1000.21"CMP
    Black5593N14000000
     

    Fiber-Optic Cable

    Image of Product. Front orientation. Fiber-Optic Cable.
    Send data between data centers and workstations in fiber-optic networks. The plastic outer jacket on this cable is flame retardant for safe indoor use, and resists water and UV light for outdoor use. Because it works both indoors and outdoors, there’s no need for a transition splice when routing the cable into buildings. Each inner fiber also has a layer of plastic insulation to protect signals and add flexibility. This cable is non-conductive, so grounding or bonding is not required.
    OFNP Cable—ONFP cable is for use in horizontal shafts, such as in ducts and above drop ceilings.
    Multimode OM3 Cable—Multimode cable is often used to transmit data over short distances, such as within buildings and local area networks (LANs). It has a large core diameter, so it’s easier to terminate and install than single-mode cable. However, it has lower bandwidth.
    Single-Mode OS2 Cable—Single-mode cable is often used to send data between buildings. It has a small core diameter, which reduces signal loss. It transmits data over longer distances and has a higher bandwidth than multimode cable.
    Fiber Count—Fiber count refers to the number of optical fibers inside a cable. The higher the count, the more data you can send. You can branch each fiber into its own individual cable if your network demands grow in the future.
    Inner
    Insulation
    Fiber
    Count
    Core Dia.,
    μm
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    For Use
    Outdoors
    Flammability Rating
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    1,000 ft.
    Long
    Single Mode OS2, OFNP
    68.30.21"BlackPlasticBlue, Brown, Gray, Green, Orange, White-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N27000000000000000000000000000000000000
    128.30.25"BlackPlasticAqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N280000000000000000000000000000000
    248.30.31"BlackPlasticAqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Purple/Black, Red, Red/Black, White, White/Black, Yellow, Yellow/Black-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N290000000000000000000000000000000000
     
    Multimode OM3, OFNP
    6500.21"BlackPlasticBlue, Brown, Gray, Green, Orange, White-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N340000000000000000000000000000000000000000
    12500.25"BlackPlasticAqua, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N35000000000000000000000000000000000000000
    24500.31"BlackPlasticAqua, Aqua/Black, Black, Black/White, Blue, Blue/Black, Brown, Brown/Black, Gray, Gray/Black, Green, Green/Black, Orange, Orange/Black, Pink, Pink/Black, Purple, Purple/Black, Red, Red/Black, White, White/Black, Yellow, Yellow/Black-40 to 155YesNFPA 262, CSA C22.2 No. 0.3 FT65499N36000000000000000000000000000000000000000000
     
    back to top