McMaster-Carr logo
    Filter by
    Connection Location
    Dial Type
    System of Measurement
    Pipe Size
    Industrial Info Compare
    Dial Diameter
    Pressure Numeric Increments
    Scale Type
    Thread Type
    Industrial Info Compare
    Measurement Unit
    Graduations
    Display Type
    Measures
    Maximum Continuous Pressure
    Accuracy Scale
    Connection Material
    Liquid Type
    Minimum Pressure
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    44 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    High-Clarity Vibration-Resistant Pressure Gauges

    These gauges have a unique case design that eliminates the air bubble on the dial face, which can distort readings. The liquid in the dial reduces needle flutter for precise readings in high-vibration applications. Use them in pumps, filters, regulators, and in process lines to measure and display pressure. Mount gauges with the dial face upright.
    Nylon Case with Brass Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. High-Clarity Vibration-Resistant Pressure Gauges, Single Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure Gauges. High-Clarity Vibration-Resistant Pressure Gauges, Single Scale, Center-Back Connection.

    Bottom Connection

    Center-Back Connection

    Image of Attribute. Bottom Connection. Front orientation. High-Clarity Vibration-Resistant Pressure Gauges, Bottom Connection.

    Bottom

    Connection

    Image of Attribute. Center-Back Connection. Front orientation. High-Clarity Vibration-Resistant Pressure Gauges, Center-Back Connection.

    Center-Back

    Connection

    Internal Seal—Gauges with an internal seal resist clogging and corrosion.
    Temp.
    Range, ° F
    Bottom
    Connection
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Liquid
    Type
    Features
    For Use With
    Accuracy
    Pressure
    Range
    Each
    Each
    Upright Mount
     
    NPT Male
    2 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3708K210000003708K51000000
    2 1/2"1/4
    Black-40 to 150-40 to 150GlycerinInternal SealAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3715K21000003715K5100000
    3 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3708K310000003708K61000000
    3 1/2"1/4
    Black-40 to 150-40 to 150GlycerinInternal SealAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3715K310000003715K61000000
    4 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi———03708K71000000
    4 1/2"1/4
    Black-40 to 150-40 to 150GlycerinInternal SealAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi———03715K71000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3543K21000003543K5100000
    3 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3543K310000003543K61000000
    4 1/2"1/4
    Black-40 to 150-40 to 150GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi———03543K71000000
     
    Nylon Case with 316 Stainless Steel Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. High-Clarity Vibration-Resistant Pressure Gauges, Single Scale, Bottom Connection.
    Image of Attribute. Bottom Connection. Front orientation. High-Clarity Vibration-Resistant Pressure Gauges, Bottom Connection.

    Bottom Connection

    Bottom

    Connection

    Internal Seal—Gauges with an internal seal resist clogging and corrosion.
    Temp.
    Range, ° F
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Environment
    Process
    Liquid
    Type
    Features
    For Use With
    Accuracy
    Pressure
    Range
    Each
    Upright Mount
     
    NPT Male
    4 1/2"1/4
    Black-40 to 150-40 to 225GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3708K50000000
    4 1/2"1/4
    Black-40 to 150-40 to 225GlycerinInternal SealAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3715K7000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    4 1/2"1/4
    Black-40 to 150-40 to 225GlycerinAir
    Hydraulic Fluid
    Water
    ±1% Full Scale (Grade 1A)0 to 7,500 psi3543K5000000
     

    Maximum-Indicating Vibration-Resistant Pressure Gauges

    These gauges have a red needle that indicates the highest pressure reached since the last setting. They have a glycerin-filled dial that reduces needle flutter for precise readings in high-vibration applications. Use them with pumps, filters, regulators, and in process lines to measure and display pressure. Mount gauges with the dial face upright.
    Brass Case with Brass Connection—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Pressure Gauges. Maximum-Indicating Vibration-Resistant Pressure Gauges, Single Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure Gauges. Maximum-Indicating Vibration-Resistant Pressure Gauges, Single Scale, Center-Back Connection.
    Image of Product. Front orientation. Pressure Gauges. Maximum-Indicating Vibration-Resistant Pressure Gauges, Single Scale, Center-Back Connection (Panel Mount).
    Image of Attribute. Bottom Connection. Front orientation. Maximum-Indicating Vibration-Resistant Pressure Gauges, Bottom Connection.
    Image of Attribute. Center-Back Connection. Front orientation. Maximum-Indicating Vibration-Resistant Pressure Gauges, Center-Back Connection.
    Image of Attribute. Center-Back Connection (Panel Mount). Front orientation. Maximum-Indicating Vibration-Resistant Pressure Gauges, Center-Back Connection (Panel Mount).

    Bottom Connection

    Center-Back

    Connection

    Center-Back Connection

    (Panel Mount)

    Bottom

    Connection

    Center-Back

    Connection

    Center-Back

    Connection

    (Panel Mount)

    Temp.
    Range, ° F
    Bottom
    Connection
    Center-Back
    Connection
    Center-Back
    Connection (Panel Mount)
    Dial
    Dia.
    Pipe
    Size
    Environment
    Process
    Liquid
    Type
    Features
    For Use With
    Accuracy
    Pressure
    Range
    Each
    Each
    For Panel
    Cutout Dia.
    Each
    Upright Mount
     
    NPT Male
    2 1/2"1/4
    0 to 1400 to 140GlycerinRed Pressure Spike NeedleAir
    Carbon Dioxide
    Ethanol
    Hydraulic Fluid
    Natural Gas
    Water
    ±1.5% Full Scale (Not Rated)0 to 7,500 psi3842K1100000003842K2100000002 1/2"3842K810000000
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    0 to 1400 to 140GlycerinRed Pressure Spike NeedleAir
    Carbon Dioxide
    Ethanol
    Hydraulic Fluid
    Natural Gas
    Water
    ±1.5% Full Scale (Not Rated)0 to 7,500 psi3842K310000003842K410000002 1/2"3842K83000000
     

    Pressure Transmitters

    Remotely monitor pressure in general purpose applications such as pumping and compressing systems. These transmitters, also known as transducers, convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Transmitters are rated NEMA 4X and IP65 or IP67 and are good for washdown and corrosive environments.
    4 mA to 20 mA Output Signal—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 4 mA to 20 mA Output Signal—Wire Lead Connection.
    Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 361 15/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K5710000000
     
    4 mA to 20 mA Output Signal—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 4 mA to 20 mA Output Signal—4-Pole M12 Plug Connection.
    Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Transmitters with a M12 plug connection are compatible with M12 connectors.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 361 11/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K1320000000
     
    4 mA to 20 mA Output Signal—DIN C Wire Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 4 mA to 20 mA Output Signal—DIN C Wire Connection.
    Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Pressure Transmitters with Calibration Certificate Traceable to NIST—Transmitters with calibration certificate traceable to NIST include documentation that states they've passed a test for accuracy.
    Pressure
    Transmitters
    Pressure Transmitters with Calibration
    Certificate Traceable to NIST
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
    Each
     
    1/8 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 36PG-7
    2 5/8"1 3/8"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K3880000000———0
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 36PG-7
    2 5/8"1 3/8"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K8510000003196K8710000000
     
    4 mA to 20 mA Output Signal—Aptiv MP 150 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 4 mA to 20 mA Output Signal—Aptiv MP 150 Plug Connection.
    Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 362 1/16"1 1/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K4520000000
     
    4 mA to 20 mA Output Signal—3-Pole DT Deutsch Style Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 4 mA to 20 mA Output Signal—3-Pole DT Deutsch Style Plug Connection.
    Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 362 1/16"1 1/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K4650000000
     
    0V DC to 5V DC Output Signal—4-Pole Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 0V DC to 5V DC Output Signal—4-Pole Wire Lead Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 361 15/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K5270000000
     
    1V DC to 5V DC Output Signal—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 1V DC to 5V DC Output Signal—Wire Lead Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 361 15/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K5420000000
     
    1V DC to 5V DC Output Signal—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 1V DC to 5V DC Output Signal—4-Pole M12 Plug Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Transmitters with a M12 plug connection are compatible with M12 connectors.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 361 11/16"7/8"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K5130000000
     
    1V DC to 5V DC Output Signal—DIN C Wire Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 1V DC to 5V DC Output Signal—DIN C Wire Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,5009 to 36PG-7
    2 5/8"1 3/8"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K3480000000
     
    0V DC to 10V DC Output Signal—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 0V DC to 10V DC Output Signal—Wire Lead Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,50014 to 361 15/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K5560000000
     
    0V DC to 10V DC Output Signal—4-Pole M12 Plug Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 0V DC to 10V DC Output Signal—4-Pole M12 Plug Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Transmitters with a M12 plug connection are compatible with M12 connectors.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,50014 to 361 11/16"15/16"IP67, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K3350000000
     
    0V DC to 10V DC Output Signal—DIN C Wire Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Pressure Transmitters, 0V DC to 10V DC Output Signal—DIN C Wire Connection.
    Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Pressure Transmitters with Calibration Certificate Traceable to NIST—Transmitters with calibration certificate traceable to NIST include documentation that states they've passed a test for accuracy.
    Pressure
    Transmitters
    Pressure Transmitters with Calibration
    Certificate Traceable to NIST
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Electrical Connection
    Thread Size
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,50014 to 36PG-7
    2 5/8"1 3/8"IP65, NEMA 4X
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.0%Glass-Filled Nylon304 Stainless Steel-40 to 2553196K86100000003196K8810000000
     

    Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas

    Often used for pressure-vessel testing and other high-pressure applications, these valves can handle at least seven times the outlet pressure of standard tank-mount pressure-regulating valves. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    For Argon, Helium, and Nitrogen
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    For Tube
    OD
    Location
    Pressure Range,
    psi
    Pressure Adjustment
    Method
    Shape
    Body
    Seal
    Temp. Range,
    ° F
    Each
    NGO Female Inlet × Swagelok® Female Outlet
    677
    SideLeft Hand
    0 to 7,500Single1/4"Bottom300 to 4,500T-Handle90° ElbowBrassPCTFE-20 to 1206677A14000000000
     

    High-Accuracy Pressure Transmitters

    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. High-Accuracy Pressure Transmitters.
    At least four times as accurate as standard pressure transmitters, these transmitters are ideal for use in laboratories and analytical testing applications. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Also known as transducers, pressure transmitters convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range.
    These transmitters connect using two wires to send a 4-20mA output current. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    All transmitters are CE marked, meaning they meet European safety standards. NEMA 4X rated transmitters are for use in washdown and corrosive environments. IP67 rated transmitters are protected from temporary submersion during washdowns.
    Transmitters with Calibration
    Certificate Traceable to NIST
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Ht.
    Wd.
    Temp. Range,
    ° F
    Enclosure
    Rating
    For Use With
    Pipe
    Connection
    Housing Material
    Connection Material
    Each
    4 mA to 20 mA Output Signal—Wire Lead Connection
     
    ±0.25% Accuracy
    0 to 5,0005,0007,5009 to 301/4
    2 1/8"1"-40 to 255IP67, NEMA 4X
    Air
    Argon
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Nitrogen
    Water
    NPT Male304 Stainless Steel
    17-4 PH Stainless Steel
    3920N190000000
     

    Economy Pressure Transmitters

    Choose these transmitters when you need reliable pressure monitoring but not high accuracy. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Rated IP65, all seal out dust and water from light rinses. They’re CE marked, so they meet European safety standards.
    These transmitters connect using two wires to send a 4-20mA output current. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    4 mA to 20 mA Output Signal—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Pressure Transmitters. Economy Pressure Transmitters.
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    For Use With
    Accuracy
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
     
    1/4 NPT Male Pipe Connection
    0 to 5,0005,0007,50012 to 361 13/16"15/16"IP65
    CE Marked
    Air
    Argon
    Diesel Fuel
    Hydraulic Fluid
    Nitrogen
    Water
    ±1.5%304 Stainless Steel
    304 Stainless Steel-20 to 2206017N220000000
     

    Adjustable-Range Pressure Transmitters

    Image of Product. Top orientation. Pressure Transmitters. Adjustable-Range Pressure Transmitters.
    Fine-tune the pressure range on these transmitters to account for changes in pressure readings over time. With an adjustable range, also known as adjustable zero and adjustable span, the top and bottom of the pressure range can be changed by up to 5%. This saves you from having to make corrections on receiving devices, such as programmable logic controllers (PLCs), remote displays, and motor speed controls. These transmitters, often called transducers, convert pressure to an electrical signal that is interpreted by receiving devices to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Rated NEMA 4X, these transmitters stand up to washdowns and corrosion.
    4 mA to 20 mA Output Signal—Transmitters with output current connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    1V DC to 5V DC Output Signal—Transmitters with output voltage connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    ±1% Accuracy
    Pressure Range,
    psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Pipe
    Connection
    Housing Material
    Connection
    Material
    Temp. Range,
    ° F
    Each
    4 mA to 20 mA Output Signal—Wire Lead Connection
    0 to 5,0005,0007,50010 to 361/4
    3"7/8"NEMA 4X
    Air
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Water
    NPT Male304 Stainless Steel
    304 Stainless Steel-20 to 18031685K6330000000
     
    1V DC to 5V DC Output Signal—Wire Lead Connection
    0 to 5,0005,0007,50010 to 361/4
    3"7/8"NEMA 4X
    Air
    Diesel Fuel
    Gasoline
    Hydraulic Fluid
    Water
    NPT Male304 Stainless Steel
    304 Stainless Steel-20 to 18031685K621000000
     