McMaster-Carr logo
    Filter by
    Draft Direction
    Electrical Phase
    Drive Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Blade Material
    Number of Speeds
    Power Source
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    226 Products

    Roof-Mount Louvers

    These louvers are gravity operated. The blades open when your roof-mounted exhaust fan goes on and close when it's off, preventing backdrafts. The felt seal on the face of the blades ensures quiet closing and better protection from the weather.
    Also Available: Additional louver sizes. Please select 8061T999 and specify louver dimensions.
    Surface Mount
    Image of Product. Front orientation. Louvers. Roof-Mount Louvers.
    Image of Specification. Side1 orientation. Surface Mount.
    Image of Product. Front orientation. Exhaust Fan Mounts.
    Image of Attribute. Front orientation. CrossSection view. Contains Annotated.

    Surface

    Mount

    Exhaust Fan Mounts

    Exhaust Fan Mounts—Exhaust fan mounts are sold separately. Louvers fit the bottom of the mount and must be secured to the lip of the mount's base with sheet metal screws (not included).
    Louvers
    8" High Exhaust
    Fan Mounts
    12" High Exhaust
    Fan Mounts
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Lg.
    Blade
    Thk.
    No. of
    Panels
    For Max. Air
    Velocity, fpm
    Temp. Range,
    ° F
    Mounting Fasteners
    Included
    Each
    Inside
    Wd.
    Each
    Inside
    Wd.
    Each
    Galvanized Steel Frame and Aluminum Blades
    13 3/4"13 3/4"13 3/4"13 3/4"0.016"12,000-40 to 180No8061T300000014 1/2"2230K11000000014 1/2"2230K640000000
    15 3/4"15 3/4"15 3/4"15 3/4"0.016"12,000-40 to 180No8061T50000016 1/2"2230K1300000016 1/2"2230K31000000
    17 3/4"17 3/4"17 3/4"17 3/4"0.016"12,000-40 to 180No8061T900000———019 1/2"2230K33000000
    19 3/4"19 3/4"19 3/4"19 3/4"0.016"12,000-40 to 180No8061T140000021 1/2"2230K16000000———0
    21 3/4"21 3/4"21 3/4"21 3/4"0.016"12,000-40 to 180No8061T1600000———023 1/2"2230K35000000
    23 3/4"23 3/4"23 3/4"23 3/4"0.016"12,000-40 to 180No8061T1900000———025 1/2"2230K36000000
    27 3/4"27 3/4"27 3/4"27 3/4"0.016"12,000-40 to 180No8061T26000000———028 1/2"2230K39000000
    34 3/4"34 3/4"34 3/4"34 3/4"0.016"12,000-40 to 180No8061T2800000035 1/2"2230K6300000035 1/2"2230K94000000
    36 3/4"36 3/4"36 3/4"36 3/4"0.016"12,000-40 to 180No8061T29000000———037 1/2"2230K45000000
     
    Motor Kits for Louvers with Galvanized Steel Frames

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 2.

    Style 1

    Style 2

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 3.

    Style 3

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient Temp.,
    ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    19"100 ft³/min @ 1/2 in. H₂O
    400 ft³/min @ 0 in. H₂O
    50 dBA @ 5 ft.1,2501/3220 3/4"14 1/2"19"40120Aluminum
    AMCA Certified, ETL Listed
    2011K2100000002230K110000000
    111"600 ft³/min @ 1/2 in. H₂O
    800 ft³/min @ 0 in. H₂O
    57 dBA @ 5 ft.1,6253/1623 3/4"16 1/4"19"37Not RatedAluminum
    AMCA Certified, ETL Listed
    2011K540000002230K11000000
    112"950 ft³/min @ 1/2 in. H₂O
    1,250 ft³/min @ 0 in. H₂O
    62 dBA @ 5 ft.1,6251/426 1/4"19 1/8"21"53Not RatedAluminum
    AMCA Certified, ETL Listed
    2011K650000002230K13000000
    114"1,800 ft³/min @ 1/2 in. H₂O
    2,100 ft³/min @ 0 in. H₂O
    66 dBA @ 5 ft.1,6251/229 3/4"21 3/4"21"56Not RatedAluminum
    AMCA Certified, ETL Listed
    2011K570000002230K13000000
    116"2,600 ft³/min @ 1/2 in. H₂O
    3,100 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,4503/433 1/4"23 3/8"24"77120Aluminum
    AMCA Certified, ETL Listed
    2011K220000002230K34000000
     
    208/230V AC Three Phase—Hardwire
    219"4,500 ft³/min @ 1/2 in. H₂O
    5,000 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,300238 15/16"32 3/4"28"189120Aluminum
    AMCA Certified, ETL Listed
    2011K23000000002230K35000000
    221"6,200 ft³/min @ 1/2 in. H₂O
    6,700 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,400538 15/16"32 1/4"28"201120Aluminum
    AMCA Certified, ETL Listed
    2011K24000000002230K35000000
    224"8,100 ft³/min @ 1/2 in. H₂O
    9,000 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.925343 7/16"37 1/4"33"288120Aluminum
    AMCA Certified, ETL Listed
    2011K25000000002230K39000000
    230"10,400 ft³/min @ 1/2 in. H₂O
    11,500 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.700552 13/16"44"40"467120Aluminum
    AMCA Certified, ETL Listed
    2011K26000000002230K94000000
    236"11,000 ft³/min @ 1/2 in. H₂O
    13,500 ft³/min @ 0 in. H₂O
    64 dBA @ 5 ft.450563 5/16"49 1/2"44"532120Aluminum
    AMCA Certified, ETL Listed
    2011K27000000002230K57000000
     
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    310"60 ft³/min @ 1/2 in. H₂O
    500 ft³/min @ 0 in. H₂O
    Not Rated1,5001/3018 5/16"11 1/4"19"21Not RatedAluminum
    AMCA Certified, ETL Listed
    2050K210000002230K11000000
    312"430 ft³/min @ 1/2 in. H₂O
    830 ft³/min @ 0 in. H₂O
    Not Rated1,5001/1020 5/16"11 3/4"19"30Not RatedAluminum
    AMCA Certified, ETL Listed
    2050K220000002230K11000000
    314"520 ft³/min @ 1/2 in. H₂O
    1,100 ft³/min @ 0 in. H₂O
    Not Rated1,1001/627 5/16"14 5/8"21"39Not RatedAluminum
    AMCA Certified, ETL Listed
    2050K130000002230K13000000
    318"1,200 ft³/min @ 1/2 in. H₂O
    2,400 ft³/min @ 0 in. H₂O
    Not Rated1,1001/333 9/16"16 3/8"26"60Not RatedAluminum
    AMCA Certified, ETL Listed
    2050K160000002230K16000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    112"1,000 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    66 dBA @ 5 ft.1,5751/326 1/4"19 1/8"21"54120Aluminum
    AMCA Certified, ETL Listed
    2050K330000002230K31000000
    114"1,900 ft³/min @ 1/2 in. H₂O
    2,300 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,5251/229 3/4"21 3/4"21"61120Aluminum
    AMCA Certified, ETL Listed
    2050K34000000002230K31000000
    116"2,850 ft³/min @ 1/2 in. H₂O
    3,300 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,525133 1/4"23 3/8"24"74120Aluminum
    AMCA Certified, ETL Listed
    2050K35000000002230K34000000
     

    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor have advanced electronic controls that allow them to precisely operate at wide range of speeds, making them more efficient, quieter, and longer lasting than fans with a standard motor.
    Cannot Be Sold To—Fans that cannot be sold to the listed areas are restricted by energy efficiency requirements.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Cannot Be
    Sold To
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    19"300 ft³/min @ 1/2 in. H₂O
    400 ft³/min @ 0 in. H₂O
    54 dBA @ 5 ft.1,3001/3217 3/4"14 1/2"19"40120Aluminum
    AMCA Certified, ETL Listed
    2232K3100000002230K640000000
    111"400 ft³/min @ 1/2 in. H₂O
    710 ft³/min @ 0 in. H₂O
    60 dBA @ 5 ft.1,6253/1622"18"19"43300Aluminum
    AMCA Certified, ETL Listed
    2232K550000002230K64000000
    111 3/4"750 ft³/min @ 1/2 in. H₂O
    1,050 ft³/min @ 0 in. H₂O
    59 dBA @ 5 ft.1,3001/425 1/2"25 1/4"21"67300Aluminum
    AMCA Certified, ETL Listed
    2232K320000002230K31000000
    112"1,100 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,6251/325 1/2"25 1/4"21"50300Aluminum
    AMCA Certified, ETL Listed
    2232K230000002230K31000000
    113 3/4"1,500 ft³/min @ 1/2 in. H₂O
    1,950 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,4751/228 7/8"27 1/4"21"78300Aluminum
    AMCA Certified, ETL Listed
    2232K340000002230K31000000
    116"2,450 ft³/min @ 1/2 in. H₂O
    2,900 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,6253/431 7/8"30 1/2"24 3/4"80300Aluminum
    AMCA Certified, ETL Listed
    2232K24000000002230K34000000
     
    208 to 230V AC, Three Phase—Hardwire
    118 3/4"3,750 ft³/min @ 1/2 in. H₂O
    4,100 ft³/min @ 0 in. H₂O
    68 dB @ 5 ft.1,150237 3/8"33 3/4"28"184300Aluminum
    AMCA Certified, ETL Listed
    2232K25000000002230K35000000
    120 3/4"5,900 ft³/min @ 1/2 in. H₂O
    6,450 ft³/min @ 0 in. H₂O
    85 dBA @ 5 ft.1,425537 3/8"33 1/4"28"221300Aluminum
    AMCA Certified, ETL Listed
    2232K37000000002230K35000000
    124"7,000 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.900341 7/8"37 1/2"33"312300Aluminum
    AMCA Certified, ETL Listed
    2232K38000000002230K39000000
    130"9,500 ft³/min @ 1/2 in. H₂O
    10,500 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.725551 1/4"44"40"497300Aluminum
    AMCA Certified, ETL Listed
    2232K39000000002230K94000000
     
    Totally Enclosed Motor Enclosure
     
    460V AC, Three Phase—Hardwire
    212"1,150 ft³/min @ 1/2 in. H₂O
    1,800 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.3,4501/318"26 3/4"22"44120Steel2081K25000000002230K115000000
    216"3,050 ft³/min @ 0 in. H₂O70 dBA @ 5 ft.1,7501/322"26 3/4"26"51120Steel2081K26000000002230K125000000
    218"3,900 ft³/min @ 0 in. H₂O69 dBA @ 5 ft.1,7503/424"34 3/4"28"77120Steel2081K27000000002230K135000000
    224"7,400 ft³/min @ 0 in. H₂O66 dBA @ 5 ft.1,7503/430"20 3/4"36"208120Steel2081K19000000002230K66000000
    230"7,300 ft³/min @ 1/2 in. H₂O
    11,700 ft³/min @ 0 in. H₂O
    66 dBA @ 5 ft.1,150236"23 1/2"42"340120SteelCalifornia2081K13000000002230K45000000
    236"14,800 ft³/min @ 0 in. H₂O68 dBA @ 5 ft.1,150144"26 3/4"48"370120Steel2081K21000000002230K48000000
    242"17,000 ft³/min @ 1/2 in. H₂O
    24,700 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,150350"29 1/2"54"471120Steel2081K15000000002230K49000000
    248"25,500 ft³/min @ 1/2 in. H₂O
    34,300 ft³/min @ 0 in. H₂O
    76 dBA @ 5 ft.1,150556"38 3/4"60"650120Steel2081K17000000002230K26000000
    254"34,150 ft³/min @ 1/2 in. H₂O
    44,700 ft³/min @ 0 in. H₂O
    88 dBA @ 5 ft.1,1257 1/262"63 1/2"64 1/4"628120Steel2081K28000000002230K145000000
    260"40,500 ft³/min @ 1/2 in. H₂O
    57,000 ft³/min @ 0 in. H₂O
    97 dBA @ 5 ft.1,1251068"63 1/2"70 1/4"640120Steel2081K29000000002230K155000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    111 3/4"1,050 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,5751/325 1/2"25 1/4"21"64300Aluminum
    AMCA Certified, ETL Listed
    2232K330000002230K31000000
    113 3/4"1,550 ft³/min @ 1/2 in. H₂O
    2,000 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,5001/228 7/8"27 1/4"21"71300Aluminum
    AMCA Certified, ETL Listed
    2232K35000000002230K31000000
    115 3/4"2,850 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.1,550131 7/8"30 1/2"24 3/4"87300Aluminum
    AMCA Certified, ETL Listed
    2232K36000000002230K34000000
     

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    12"1,250 ft³/min @ 1/2 in. H₂O
    1,500 ft³/min @ 0 in. H₂O
    64 dB @ 5 ft.Direct1,725Variable151 1/8"29 1/2"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N11000000000
    14"2,100 ft³/min @ 1/2 in. H₂O
    2,500 ft³/min @ 0 in. H₂O
    66 dB @ 5 ft.Direct1,650Variable155 3/8"31"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1200000000
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    16"3,000 ft³/min @ 1/2 in. H₂O
    3,500 ft³/min @ 0 in. H₂O
    71 dB @ 5 ft.Direct1,650Variable1 1/259 3/4"32 5/8"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N13000000000
    19"3,800 ft³/min @ 1/2 in. H₂O
    4,500 ft³/min @ 0 in. H₂O
    76 dB @ 5 ft.Direct1,175Variable1 1/266 1/8"37 1/2"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1400000000
    21"5,000 ft³/min @ 1/2 in. H₂O
    5,500 ft³/min @ 0 in. H₂O
    77 dB @ 5 ft.Direct1,275Variable371 7/8"38 1/4"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1500000000
    25"5,500 ft³/min @ 1/2 in. H₂O
    6,500 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct900Variable380 3/8"49 1/4"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1600000000
    31"7,000 ft³/min @ 1/2 in. H₂O
    8,500 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct675Variable585 7/8"52 1/4"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1700000000
    37"12,000 ft³/min @ 1/2 in. H₂O
    14,000 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct575Variable7 1/293 1/4"59"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1800000000

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC/208 to 230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    16"2,800 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.Belt1,14513/433 11/16"29 1/4"26"Aluminum
    Aluminum
    Bird Screen2207K310000000002230K340000000
    20"4,900 ft³/min @ 1/2 in. H₂O
    5,400 ft³/min @ 0 in. H₂O
    74 dBA @ 5 ft.Belt1,08011 1/238 1/4"31 3/4"30"Aluminum
    Aluminum
    Bird Screen2207K32000000002230K36000000
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    24"6,900 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.Belt8751244 1/4"39 11/16"33"Aluminum
    Aluminum
    Bird Screen2207K330000000002230K390000000

    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Direct Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,900 ft³/min @ 1/2 in. H₂O
    6,900 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,1503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N110000000002230K660000000
    30"5,900 ft³/min @ 1/2 in. H₂O
    9,350 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.1,150139"28"42"370100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N12000000002230K45000000
     
    240/460V AC, Three Phase—Hardwire
    36"15,700 ft³/min @ 1/2 in. H₂O
    21,000 ft³/min @ 0 in. H₂O
    79 dBA @ 5 ft.1,150345"31"48"480100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N13000000002230K48000000
    42"19,400 ft³/min @ 1/2 in. H₂O
    25,300 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,150351"34"54"520100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N14000000002230K49000000
    48"31,600 ft³/min @ 1/2 in. H₂O
    36,200 ft³/min @ 0 in. H₂O
    89 dBA @ 5 ft.1,1507 1/257"37"60"670100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N15000000002230K26000000
     
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,530 ft³/min @ 1/2 in. H₂O
    6,150 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,7503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N210000000002230K660000000
    30"2,950 ft³/min @ 1/2 in. H₂O
    9,800 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,7503/439"28"42"410100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N22000000002230K45000000
     
    240/460V AC, Three Phase—Hardwire
    36"20,200 ft³/min @ 1/2 in. H₂O
    24,100 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,750545"31"48"590100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N23000000002230K48000000
    42"22,400 ft³/min @ 1/2 in. H₂O
    27,800 ft³/min @ 0 in. H₂O
    78 dBA @ 5 ft.1,750551"34"54"720100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N24000000002230K49000000
    48"28,600 ft³/min @ 1/2 in. H₂O
    36,700 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,750557"37"60"840100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N25000000002230K26000000
     

    Wind-Driven Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Contains Annotated. Exhaust Fans. Wind-Driven Roof-Mount Exhaust Fans .
    Designed to spin freely with the slightest breeze, these fans create a vacuum that draws air out from buildings and ventilation systems—no electricity required. They are also known as turbine ventilators. Mount fans on your roof away from wind obstructions.
    Base
    Dia.
    Overall
    Ht.
    Airflow @ Wind Speed
    Thk.
    Max. Temp.,
    ° F
    Each
    Galvanized Steel
    6"14 1/2"145 ft³/min @ 4 mph0.018"1501992K120000000
    8"15 1/2"255 ft³/min @ 4 mph0.018"1501992K14000000
    10"16 3/4"425 ft³/min @ 4 mph0.018"1501992K16000000
    12"17 1/4"630 ft³/min @ 4 mph0.024"1501992K17000000
    14"20"700 ft³/min @ 4 mph0.024"1501992K18000000
    16"22 1/2"950 ft³/min @ 4 mph0.024"1501992K21000000
    18"24"1,200 ft³/min @ 4 mph0.024"1501992K22000000
    20"24 1/2"1,700 ft³/min @ 4 mph0.024"1501992K23000000
    24"29 1/2"2,350 ft³/min @ 4 mph0.024"1501992K24000000
    30"32"2,700 ft³/min @ 4 mph0.03"1501992K25000000
    36"38"4,000 ft³/min @ 4 mph0.03"1501992K27000000
     
    Stainless Steel
    6"14 1/2"110 ft³/min @ 4 mph0.018"1501992K43000000
    8"15 1/2"195 ft³/min @ 4 mph0.018"1501992K45000000
    10"16 3/4"305 ft³/min @ 4 mph0.018"1501992K47000000
    12"17 1/4"440 ft³/min @ 4 mph0.024"1501992K48000000
    14"20"600 ft³/min @ 4 mph0.024"1501992K49000000
    16"22 1/2"790 ft³/min @ 4 mph0.024"1501992K52000000
    18"24"1,000 ft³/min @ 4 mph0.024"1501992K53000000
    20"24 1/2"1,200 ft³/min @ 4 mph0.024"1501992K54000000
    24"29 1/2"1,700 ft³/min @ 4 mph0.024"1501992K55000000
     
    Mounting Bases
    back to top