McMaster-Carr logo
    Filter by
    System of Measurement
    Key Included
    Key Entry
    Wire Connection
    Number of Terminals
    Switch Action
    Industrial Info Compare
    Conduit Thread Type
    Industrial Info Compare
    Input Voltage
    Industrial Info Snippet
    Number of Circuits Controlled
    Housing Material
    Conduit Connection Gender
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    85 Products

    Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Frame-Mounted Safety Switches.

    Key Shown Actuating from the Side

    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style A.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style B.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style C.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style D.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style E.

    Style A

    Style

    B

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style F.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style G.
    Image of Product. Front orientation. Safety Switches. Frame-Mounted Safety Switches, Style H.
    Image of Product. Front orientation. Contains Inset. Safety Switches. Frame-Mounted Safety Switches, Style J.

    Style F

    Style G

    Style H

    Style J

    Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
    Styles A-G—Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
    Style J—Style J switches have extra safety controls to prevent you from getting trapped next to running machinery. They actuate with the turn of a portable key. Bring the key when you enter an enclosure to ensure machinery won’t start while you’re inside, even if the door closes behind you. As an added fail-safe, a rear release button lets you cut power from inside of enclosures if needed. These switches have light-up indicators that show when they're properly installed and whether they're actuated.
    IP67 Enclosure Rating—IP67 rated switches protect against temporary submersion.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches protect against washdowns.
    NEMA 6 Enclosure Rating—NEMA 6 rated switches protect against both temporary submersion and washdowns.
    Key Included—All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Size
    Thread
    Type
    Key
    Included
    Enclosure
    Rating
    Each
    Wire Lead Connection with Positive-Force Normally Closed Contacts
    A21 Off and 1 On
    Maintained
    2DPST-1NO/1NC
    8 amp @ 120V AC, 4 amp @ 24V DC250V AC
    24V DC
    3.3"1.2"1.2"M16
    Metric
    YesIP67
    65665K250000000
     
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    B21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    3"1"1.1"1/2
    NPT
    YesIP67, NEMA 6
    65665K32000000
    C21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    10 amp @ 120V AC, 2 amp @ 24V DC250V AC
    24V DC
    3.6"2.1"1.3"1/2
    NPT
    YesIP65, NEMA 4
    65665K13000000
    C31 Off and 2 On
    Maintained
    33PST-1NO/2NC
    8 amp @ 120V AC, 4 amp @ 24V DC600V AC
    250V DC
    3.5"2.1"1.2"1/2
    NPT
    YesIP67
    65665K15000000
    C31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    4 amp @ 230V AC, 4 amp @ 24V DC500V AC
    24V DC
    3.5"2"1.2"M16
    Metric
    YesIP67
    65665K18000000
    D31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    6 amp @ 120V AC, 0.27 amp @ 24V DC240V AC
    250V DC
    3.8"1.2"1.2"1/2
    NPT
    YesIP67
    65665K1600000
    E21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    8 amp @ 230V AC, 5 amp @ 24V DC400V AC
    24V DC
    4.2"2"1.6"M20
    Metric
    NoIP67
    65665K4300000
    E22 On
    Maintained
    4DPST-NC
    8 amp @ 230V AC, 5 amp @ 24V DC400V AC
    24V DC
    4.2"2"1.6"M20
    Metric
    NoIP67
    65665K2200000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K112000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K111000000
    F21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K105000000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"M20
    Metric
    NoIP67
    65665K11300000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    BSPP
    NoIP67
    65665K10800000
    F22 On
    Maintained
    4DPST-NC
    2 amp @ 400V AC400V AC4.4"1.6"1.6"1/2
    NPT
    NoIP67
    65665K109000000
     
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts and Rotating Head
    C31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    5 amp @ 120V AC, 5 amp @ 24V DC400V AC
    400V DC
    3.5"2"1.3"1/2
    NPT
    YesIP65
    65665K51000000
    D31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    10 amp @ 120V AC, 2.5 amp @ 125V DC240V AC
    250V DC
    3.8"1.2"1.2"M20
    Metric
    NoIP67
    65665K2900000
    G31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    10 amp @ 230V AC, 4 amp @ 24V DC250V AC
    24V DC
    4.3"1.6"1.4"M20
    Metric
    NoIP67
    65665K19000000
     
    Screw-Terminal Wire Connection with Rotating Head
    H42 Off and 2 On
    Maintained
    84PST-2NO/2NC
    2.5 amp @ 120V AC, 1 amp @ 125V DC120V AC
    125V DC
    7.1"1.5"1.5"1/2
    NPT
    NoIP67
    65665K31000000
     
    Screw-Terminal Wire Connection with Rear Release Button, Portable Key, and LED Status Indicator
    J62 Off and 4 OnMaintained
    126PST-2NO/4NC3 amp @ 240V AC, 2.5 amp @ 250V DC240V AC
    250V DC
    5.2"4.6"2.2"M20
    Metric
    YesIP67
    65665K101000000
     
    Actuator Keys

    Access-Delay Frame-Mounted Safety Switches

    Image of ProductInUse. Key Shown Actuating from the Side. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches.

    Key Shown Actuating from the Side

    Image of Product. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches, Style A.
    Image of Product. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches, Style B.

    Style A

    Style B

    Image of Product. Front orientation. Safety Switches. Access-Delay Frame-Mounted Safety Switches, Style C.

    Style C

    Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
    Styles A and B—Style A and B have a key entry on the top and side of the switch.
    Style C—Style C has a key entry on two opposite sides of the switch.
    Housing
    Conduit
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Input Voltage
    Holding
    Force, lbf
    Ht.
    Wd.
    Dp.
    Trade
    Size
    Thread
    Type
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts
    A31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    24V AC, 24V DC2254.7"2.3"1.4"1/2
    NPT
    IP67, NEMA 6
    7787K610000000
    A31 Off and 2 On
    Maintained
    63PST-1NO/2NC
    5 amp @ 120V AC, 2 amp @ 24V DC500V AC
    250V DC
    110V AC2254.7"2.3"1.4"1/2
    NPT
    IP67, NEMA 6
    7787K62000000
    B31 Off and 2 On
    Maintained
    143PST-1NO/2NC
    3 amp @ 120V AC, 2.5 amp @ 24V DC240V AC
    250V DC
    24V DC2253.7"3.5"1.4"1/2
    NPT
    IP67
    7787K64000000
     
    Screw-Terminal Wire Connection with Positive-Force Normally Closed Contacts and Rotating Head
    C42 Off and 2 On
    Maintained
    84PST-2NO/2NC
    4 amp @ 120V AC, 4 amp @ 24V DC240V AC
    24V DC
    24V AC, 24V DC2257.6"1.2"1.6"1/2
    NPT
    IP67
    7787K12000000
     
    Keys

    30 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. 30 mm Panel-Mount Key Switches.
    These switches require a key to turn circuits on or off, limiting access to sensitive equipment. Rated NEMA 6, 13, and IP66, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key. They include enough contact blocks to control the number of circuits listed.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure Rating
    Each
    2 Positions with Metal Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    11 Off
    Maintained
    2SPST-NO
    6 amp @ 120V AC, 2.5 amp @ 24V DC600V AC
    600V DC
    1 5/16"1 5/8"42LeftNEMA 6, NEMA 13, IP66
    9235K510000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    6 amp @ 120V AC, 2.5 amp @ 24V DC600V AC
    600V DC
    1 5/16"1 5/8"42LeftNEMA 6, NEMA 13, IP66
    9235K52000000
     
    Accessories and Replacements for Key Switches

    22 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. 22 mm Panel-Mount Key Switches.
    Limit access to sensitive equipment—these switches require a key to actuate. They're rated IP66, IP69K, NEMA 3S, NEMA 4X, and NEMA 13, and are UL and C-UL Recognized Components. Switches include enough contact blocks to control the number of circuits listed. Contact blocks are rated IP20 and are UL and C-UL Listed. Use BACO legend plates (not included) to label switches.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure Rating
    Mfr.
    Each
    2 Positions with Plastic Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    11 Off
    Maintained
    2SPST-NO
    Black6 amp @ 120V AC, 2.5 amp @ 24V DC600V AC
    600V DC
    1 3/16"1 11/16"62LeftNEMA 3S, NEMA 4X, NEMA 13, IP20, IP66, IP69K, IK05
    BACO Controls6749K3000000
     
    Accessories and Replacements for Key Switches

    30 mm Panel-Mount Build-Your-Own Metal Push-Button Switches

    Choose an actuator and contact block to make your own switch. All switches are rated for protection from washdowns and oil/coolant spraying. NEMA 4X rated switches are also protected from corrosion. Use legend plates (not included) to label switches.
    Key Actuators
    Image of Product. Front orientation. Key Actuators. 30 mm Panel-Mount Build-Your-Own Metal Push-Button Switches.
    Key actuators are keyed alike, so they will all open with the same key.
    Switch
    Action
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Key
    No.
    Enclosure
    Rating
    Certification
    Each
     
    2 Positions
    Momentary
    6 amp @ 120V AC, 5 amp @ 24V DC600V AC
    600V DC
    1 1/8"42Left501CHNEMA 4, NEMA 13
    CSA Certified, UL Listed
    65575K250000000
    Maintained
    6 amp @ 120V AC, 5 amp @ 24V DC600V AC
    600V DC
    1 1/8"42Left, Right501CHNEMA 4, NEMA 13
    CSA Certified, UL Listed
    65575K27000000
     
    3 Positions
    Momentary
    6 amp @ 120V AC, 5 amp @ 24V DC600V AC
    600V DC
    1 1/8"42Center501CHNEMA 4, NEMA 13
    CSA Certified, UL Listed
    65575K29000000
    Maintained
    6 amp @ 120V AC, 5 amp @ 24V DC600V AC
    600V DC
    1 1/8"42Center, Left, Right501CHNEMA 4, NEMA 13
    CSA Certified, UL Listed
    65575K28000000
     
    Replacement Keys

    16 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. 16 mm Panel-Mount Key Switches.
    Limit access to sensitive equipment—these switches require a key to actuate. Rated NEMA 4, 13, and IP65, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Quick-Disconnect
    Tab Wd.
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure Rating
    Each
    2 Positions with Plastic Actuator Base
     
    Keyed Alike with Quick-Disconnect-Terminal Wire Connection
    11 Off
    Momentary
    4SPST-NO
    Black2.5 amp @ 125V AC, 6 amp @ 24V DC250V AC
    250V DC
    11/16"1 11/16"30.11"2CenterNEMA 4, NEMA 13, IP65
    65645K41000000
    11 Off
    Maintained
    4SPST-NO
    Black2.5 amp @ 125V AC, 6 amp @ 24V DC250V AC
    250V DC
    11/16"1 11/16"30.11"2Center, RightNEMA 4, NEMA 13, IP65
    65645K4200000
    22 Off
    Maintained
    6DPST-NO
    Black2.5 amp @ 125V AC, 6 amp @ 24V DC250V AC
    250V DC
    11/16"1 11/16"30.11"2Center, RightNEMA 4, NEMA 13, IP65
    65645K4300000
     
    3 Positions with Plastic Actuator Base
     
    Keyed Alike with Quick-Disconnect-Terminal Wire Connection
    22 Off
    Momentary
    6DPST-NO
    Black2.5 amp @ 125V AC, 6 amp @ 24V DC250V AC
    250V DC
    11/16"1 11/16"20.11"2CenterNEMA 4, NEMA 13, IP65
    65645K4400000
    22 Off
    Maintained
    6DPST-NO
    Black2.5 amp @ 125V AC, 6 amp @ 24V DC250V AC
    250V DC
    11/16"1 11/16"20.11"2Center, Left, RightNEMA 4, NEMA 13, IP65
    65645K4500000
     
    Accessories and Replacements for Key Switches

    22 mm Panel-Mount Build-Your-Own Metal Push-Button Switches

    Choose an actuator and contact block to make your own switch. All switches are IP and NEMA rated for protection from dust, washdown, and chemicals. For an easy way to tell switches apart without labels, choose them based on their actuator color.
    Key Actuators
    Image of Product. Front orientation. Key Actuators. 22 mm Panel-Mount Build-Your-Own Metal Push-Button Switches.
    Key actuators prevent accidental activation because they require a key to turn on and off. They are keyed alike, so they will all open with the same key.
    Switch Action
    Dia.
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Key
    No.
    Enclosure Rating
    Certification
    Specs.
    Met
    Actuator
    Color
    Each
     
    2 Positions
    Momentary
    1 3/16"62Right3825IP66, NEMA 4, NEMA 13
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    UL 508Black9209K61000000
    Maintained
    1 3/16"62Left3825IP66, NEMA 4, NEMA 13
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    UL 508Black9209K6300000
     
    3 Positions
    Momentary, Maintained
    1 3/16"62Left3825IP66, NEMA 4, NEMA 13
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    UL 508Black9209K6200000
    Maintained
    1 3/16"62Left3825IP66, NEMA 4, NEMA 13
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    UL 508Black9209K6400000
     
    Accessories and Replacements for Key Actuators

    Vibration-Resistant 22 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. Vibration-Resistant 22 mm Panel-Mount Key Switches.
    To prevent accidental actuation and limit access to sensitive equipment, these switches require a key to turn circuits on or off. The contact block and actuator are all one piece, so they won’t separate in high-vibration applications. Install them in a standard panel cutout. They’re keyed alike, so they will all open with the same key.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Actuator
    Color
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure Rating
    Each
    2 Positions with Plastic Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    11 Off
    Maintained
    2SPST-NO
    Black0.6 amp @ 120V AC, 0.22 amp @ 125V DC240V AC
    250V DC
    1 1/8"1 11/16"2LeftNEMA 3, NEMA 12, IP65
    6961N11000000
     
    3 Positions with Plastic Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    22 Off
    Maintained
    4DPST-NO
    Black0.6 amp @ 120V AC, 0.22 amp @ 125V DC240V AC
    250V DC
    1 1/8"1 11/16"2CenterNEMA 3, NEMA 12, IP65
    6961N1200000
     

    Washdown 3/4" Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. Washdown 3/4" Panel-Mount Key Switches, Screw-Terminal Wire Connection.

    Screw-Terminal Wire

    Connection

    Rated NEMA 4 or IP66, these switches are protected from washdowns. They require a key to turn circuits on or off, limiting access to sensitive equipment. All fit into a standard panel cutout.
    Keyed Alike—Keyed alike switches all open with the same key.
    Key Switches
    Replacement Keys
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Dia.
    Dp. Behind
    Panel
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure
    Rating
    Each
    Each
    2 Positions with Metal Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    20 amp @ 240V AC6907/8"2 5/8"2Center, RightIP66
    7182K1010000007182K200000
     

    Battery Disconnect Switches

    Stop battery drain and prevent the theft or unauthorized use of equipment by disconnecting batteries when not in use.
    Key Actuator for Remote Mounting with Water-Resistant Cover
    Image of Product. Front orientation. Disconnect Switches. Battery Disconnect Switches, Key Actuator for Remote Mounting with Water-Resistant Cover.
    Knob, key, and T-handle actuators can be removed to limit access to the switch.
    Use remote-mount switches to cut power to your battery from a distance. Run a battery cable from the battery to the switch.
    Max. Continuous Current
    @ Voltage
    Key Removal
    Position
    Material
    Ht.
    Dia.
    No. of Mounting
    Holes
    Mounting
    Hole Dia.
    Includes
    Each
    100 amp @ 12V DCOffBrass/Copper2 1/2"2 1/4"20.19"Two Keys7110K42000000

    Hazardous Location 30 mm Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. Hazardous Location 30 mm Panel-Mount Key Switches.
    Designed for use near ignitable gases, fibers, and dust, these switches have a housing that seals in anything that could ignite flammable material. You’ll know they’re safe because they’re NEC Class 1, Division 2 Groups A-D and NEC Zone 1 Groups IIC-IIA certified for hazardous locations. These switches require a key to turn circuits on or off, preventing accidental actuation and limiting access to sensitive equipment. Since they’re keyed alike, all open with the same key. Install them in a standard panel cutout.
    2 Circuits Controlled—Switches that control two circuits come with a contact block for each circuit.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Enclosure
    Rating
    Each
    2 Positions with Plastic Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    11 Off
    Momentary
    2SPST-NO
    6 amp @ 120V AC, 4 amp @ 24V DC500V AC
    500V DC
    1 9/16"2 5/8"32LeftIP20
    6914N130000000
    11 Off
    Maintained
    2SPST-NO
    6 amp @ 120V AC, 4 amp @ 24V DC500V AC
    500V DC
    1 9/16"2 5/8"32Left, RightIP20
    6914N11000000
    11 On
    Maintained
    2SPST-NC
    6 amp @ 120V AC, 4 amp @ 24V DC500V AC
    500V DC
    1 9/16"2 5/8"32Left, RightIP20
    6914N12000000
    21 Off and 1 On
    Maintained
    4DPST-1NO/1NC
    6 amp @ 120V AC, 4 amp @ 24V DC500V AC
    500V DC
    1 9/16"2 5/8"32Left, RightIP20
    6914N14000000
     
    3 Positions with Plastic Actuator Base
     
    Keyed Alike with Screw-Terminal Wire Connection
    22 Off
    Maintained
    4DPST-NO
    6 amp @ 120V AC, 4 amp @ 24V DC500V AC
    500V DC
    1 9/16"2 5/8"32Center, Left, RightIP20
    6914N15000000
     
    Accessories and Replacements for Key Switches

    22 mm Panel-Mount Build-Your-Own Plastic Push-Button Switches

    Choose an actuator and contact block to make your own switch. Actuators are rated NEMA 3S, 4X and 13 for protection from dust, outdoor environments, corrosion, oil, and washdowns. They mount into standard panel cutouts. Use legend plates (not included) to label switches. BACO Controls switches are only compatible with BACO manufactured legend plates.
    Key Actuators
    Image of Product. Front orientation. Key Actuators. 22 mm Panel-Mount Build-Your-Own Plastic Push-Button Switches.
    Key actuators prevent accidental activation because they require a key to turn on and off. They are keyed alike, so they will all open with the same key.
    Switch Mounting Tools—Mounting tools make it easier to install switches in crowded panels.
    Key Actuators
    Switch
    Mounting Tools
    Switch Action
    Dia.
    For Max. No. of
    Contact Blocks
    No. of Keys
    Included
    Key Removal
    Position
    Key
    No.
    Enclosure Rating
    Certification
    Specs.
    Met
    Mfr.
    Actuator
    Color
    Each
    Each
     
    2 Positions
    Momentary
    1 3/16"62Left455IK05, IP66, IP69K, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsBlack7556K720000007550K95000000
    Maintained
    1 3/16"62Left455IK05, IP66, IP69K, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsBlack7556K71000007550K9500000
     
    3 Positions
    Momentary, Maintained
    1 3/16"62Center455IK05, IP66, IP69K, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsBlack7556K82000007550K9500000
    Momentary
    1 3/16"62Center455IK05, IP66, IP69K, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsBlack7556K83000007550K9500000
    Maintained
    1 3/16"62Center455IK05, IP66, IP69K, NEMA 3S, NEMA 4X, NEMA 13
    C-UL Recognized Component, UL Recognized Component
    UL 508BACO ControlsBlack7556K81000007550K9500000
     
    Replacement Keys
    back to top