Flow Pattern Flow Pattern |
---|
![]() | 3/2 |
Actuation Actuation |
---|
![]() | Manual |
For Use With For Use With |
---|
|
Actuator Style Actuator Style |
---|
![]() | Dial |
Inlet Thread Type Inlet Thread Type |
---|
|
Air Directional Control Valve Type Air DirectionalControl Valve Type |
---|
|
Return Actuation Return Actuation |
---|
|
For Air Cylinder Type For Air Cylinder Type |
---|
|
Exhaust Thread Type Exhaust Thread Type |
---|
|
Outlet Thread Type Outlet Thread Type |
---|
|
Valve Function Valve Function |
---|
|
Number of Flow Positions Number of Flow Positions |
---|
|
Valve Starting Position Valve Starting Position |
---|
|
Number of Flow Ports Number of Flow Ports |
---|
|
Outlet Connection Type Outlet Connection Type |
---|
![]() | Pipe |
Number of Outlet Ports Number of Outlet Ports |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Specifications Met Specifications Met | Show |
---|
Specifications Met Specifications Met | Hide |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Safety-Lockout Single-Action Air Directional Control Valves

To prevent accidental start-up, these valves can be locked in their off position with a padlock. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're normally closed to block airflow until actuated. Return actuation is by hand, so they stay actuated and return to their starting position only when you move the actuator again. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated. They help meet OSHA 29 CFR 1910.147 procedures for the control of energy sources that could injure workers.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Specifications Met | Lg. | Wd. | Ht. | Mounting Fasteners Included | Padlock Included | For Max. Padlock Shackle Dia. | Each | |
Threaded Female Inlet × Threaded Female Outlet | ||||||||||||||||
3 | 1/8 NPT | 1/8 NPT | Threaded | 5 | 0.65 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 1 5/8" | 1 3/4" | 2 5/8" | No | No | 25/64" | 00000000 | 000000 |
3 | 1/4 NPT | 1/4 NPT | Threaded | 113 | 2 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 2 3/4" | 2 1/2" | 4 1/4" | No | No | 25/64" | 00000000 | 00000 |
3 | 3/8 NPT | 3/8 NPT | Threaded | 116 | 3 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 2 3/4" | 2 1/2" | 4 1/4" | No | No | 25/64" | 00000000 | 00000 |
3 | 1/2 NPT | 1/2 NPT | Threaded | 215 | 3.8 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 2 3/4" | 2 1/2" | 4 1/4" | No | No | 25/64" | 00000000 | 00000 |
3 | 3/4 NPT | 3/4 NPT | Threaded | 361 | 6.4 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 3 5/8" | 3 1/4" | 5 3/8" | No | No | 25/64" | 00000000 | 00000 |
3 | 1 NPT | 1 NPT | Threaded | 481 | 8.6 | 15-145 | Not Rated | OSHA Compliant 29 CFR 1910.147 | 3 5/8" | 3 1/4" | 5 3/8" | No | No | 25/64" | 00000000 | 00000 |