    35 Products

    Thermocouple Probes for Liquids and Gases

    Made of stainless steel, these probes measure the temperature of liquids and gases without corroding. They’re also safe to use with solids, such as molds and dies, because the stainless steel acts as a shield if they’re hit or bumped. If space is tight, bend them up to 90°. They have a protective layer of magnesium oxide to keep the wiring inside the probe from kinking when they’re bent. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    316 Stainless Steel Probes without Cable
    Image of Product. Front orientation. Thermocouples. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.
    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes.

    Flat-Pin Mini

    Connector

    Round-Pin Connector

    Probes without a cable have a connector already attached, so they’re ready to plug into a portable thermometer for temperature-monitoring on the go. You can also connect these probes to remote devices using thermocouple extension wire with connectors.
    Probe
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K62000000
    18"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K47600000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K4200000
    18"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K95100000
    18"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K5200000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded39095K6500000
    18"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3871K51400000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K8400000
    18"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K95200000
    18"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGrounded3856K8700000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded39095K6800000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K4800000
    18"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K95300000
    18"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGrounded3856K5800000
     
    316 Stainless Steel Probes with Cable
    Image of Product. Probe with Cable and Connector. Front orientation. Probes with Cable. Thermocouple Probes for Liquids and Gases .

    Probe with Cable and

    Connector

    Image of Specification. Flat-Pin Mini Connector. Front orientation. ZoomedIn view. Contains Border. Flat-Pin Mini Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes with Cable.

    Flat-Pin Mini

    Connector

    Image of Specification. Round-Pin Connector. Front orientation. ZoomedIn view. Contains Border. Round-Pin Thermocouple Connector. Thermocouple Probes for Liquids and Gases , Probes with Cable.

    Round-Pin Connector

    Probes with a cable have either a connector or wire leads to connect to devices installed nearby. Those with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
    Probe
    Cable
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Each
    Type J
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass90039095K52000000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.6970±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K5200000
    18"3/16"0.91,150±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K25100000
    18"1/4"1.31,330±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K6200000
     
    Type K
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass90039095K5500000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.61,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K9200000
    18"3/16"0.91,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K25200000
    18"1/4"1.31,700Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedGroundedStraight3Fiberglass9003857K9500000
     
    Type T
     
    Flat-Pin Mini Thermocouple Connector
    18"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass90039095K5800000
     
    Round-Pin Thermocouple Connector
    18"1/8"0.6700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K5800000
    18"3/16"0.9700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K25300000
    18"1/4"1.3700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    InsulatedGroundedStraight3Fiberglass9003857K6800000
     

    High-Temperature Thermocouple Probes for Air and Surfaces

    Thick wire with ceramic insulation stands up to extreme temperatures in forging, die casting, and heat treating. These probes have an exposed tip that's quick to respond to air and surface temperature changes but can't be used in liquids. Pick the thermocouple type that best covers the temperature range you expect the air or surface to be. You should also make sure the thermocouple type you choose is compatible with the device you plan to connect it to. They're often used with temperature controllers, thermometers, and other temperature-reading devices.
    These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    Probes
    Image of Product. Front orientation. Thermocouples. High-Temperature Thermocouple Probes for Air and Surfaces .
    Probe
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time, sec.
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    18"1/4"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K42000000
    18"1/2"51,400±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3200000
     
    Type K
     
    Wire Leads
    18"1/4"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"14
    3859K4500000
    18"1/2"52,300Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    InsulatedExposed1 1/2"8
    3859K3500000
     

    Noninsulated Thermocouple Probes for Liquids and Gases

    An economical alternative to insulated thermocouple probes, these probes measure the temperature of liquids and gases. Made of stainless steel, they resist corrosion. The stainless steel also shields the sensor from impact, so you can use them with solids, such as in molds and dies. Because there is no insulation to protect the internal wires, you should not bend these probes. They’re also known as tube-and-wire thermocouples.
    To view and store measurements, add a connector to the wire leads and connect these probes to a controller, thermometer, or other temperature-reading device. You can also attach thermocouple wire to the wire leads if you need to extend the probe’s reach. Pick the thermocouple type that best covers the temperature range you expect your liquid, gas, or solid to be. You should also make sure the thermocouple type you choose is compatible with the device you connect it to.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Note: When installing probes with wire leads, the red wire is negative.
    304 Stainless Steel Probes with Cable
    Image of Product. Front orientation. Thermocouples. Noninsulated Thermocouple Probes for Liquids and Gases .
    Probe
    Cable
    Wire
    Lead
    Lg.
    Dia.
    Response
    Time
    Max. Temp.,
    ° F
    Accuracy @ Temperature
    Insulation
    Sensor
    Type
    Style
    Lg.,
    ft.
    Material
    Max. Temp.,
    ° F
    Lg.
    AWG
    Each
    Type J
     
    Wire Leads
    18"3/16"Not Rated900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K117000000
    18"1/4"Not Rated900±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K11800000
     
    Type K
     
    Wire Leads
    18"3/16"Not Rated900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K12800000
    18"1/4"Not Rated900Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K12900000
     
    Type T
     
    Wire Leads
    18"1/4"Not Rated700Not Rated Below 32° F
    ±1.8° F Between 32° F to 240° F
    ±0.75% Above 240° F
    NoninsulatedGroundedStraight4Fiberglass9003"20
    3871K13800000
     