Panel-Mount Electrically Actuated Hour Meters













Display running time on a machine so you can schedule preventative maintenance.
Non-resettable counters prevent tampering and accidental loss of data.
Counters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
For Panel Cutout | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | Number of Digits | Dia. | Wd. | Ht. | Ht. | Wd. | Dp. | Dia. | Operating Voltage | Environmental Rating | Each | ||
Screw On | ||||||||||||||
Wire Leads | ||||||||||||||
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 24V AC | __ | 0000000 | 0000000 |
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 120V AC | __ | 0000000 | 00000 |
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 230V AC | __ | 0000000 | 000000 |
B | No | Up | 6 | __ | 2.3" | 2.3" | __ | __ | 2.5" | 3" | 120V AC | __ | 0000000 | 00000 |
B | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2.5" | 3.5" | 120V AC | __ | 0000000 | 00000 |
E | No | Up | 5 | __ | 1.5" | 1" | __ | __ | 1.9" | 2.9" | 120V AC | __ | 0000000 | 00000 |
F | No | Up | 5 | __ | 1.5" | 1" | 1.1" | 2.1" | 1.9" | __ | 120V AC | __ | 0000000 | 00000 |
Screw Terminals | ||||||||||||||
A | No | Up | 6 | 2.3" | __ | __ | __ | __ | 2" | 2.9" | 120V AC | __ | 0000000 | 00000 |
N | Yes | Up | 8 | __ | 1.8" | 0.9" | 1" | 1.9" | 2.1" | __ | 10-240V AC, 5-110V DC | __ | 00000000 | 00000 |
0.25" Quick-Disconnect Terminals | ||||||||||||||
C | No | Up | 6 | __ | 1.5" | 1" | 0.92" | 1.43" | 2.15" | __ | 10-80V DC | __ | 0000000 | 00000 |
C | No | Up | 6 | __ | 1.5" | 1" | 0.92" | 1.43" | 2.15" | __ | 115-230V AC | __ | 0000000 | 00000 |
E | No | Up | 5 | __ | 1.5" | 1" | __ | __ | 1.9" | 2.9" | 8-32V DC | __ | 0000000 | 00000 |
F | No | Up | 5 | __ | 1.5" | 1" | 1.1" | 2.1" | 1.9" | __ | 8-32V DC | __ | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 24V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 120V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.8" | 230V AC | IP65, NEMA 4X | 0000000 | 00000 |
G | No | Up | 6 | 2" | __ | __ | __ | __ | 2" | 2.8" | 10-80V DC | __ | 0000000 | 00000 |
L | No | Up | 6 | __ | 1.5" | 1" | 1.3" | 2.1" | 0.8" | __ | 15-75V AC, 9-60V DC | __ | 0000000 | 00000 |
L | No | Up | 6 | __ | 1.5" | 1" | 1.3" | 2.1" | 0.8" | __ | 75-270V AC, 36-185V DC | __ | 0000000 | 00000 |
Press On | ||||||||||||||
Screw Terminals | ||||||||||||||
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 24V AC | __ | 0000000 | 000000 |
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 120V AC | __ | 0000000 | 000000 |
D | No | Up | 7 | __ | 1.8" | 0.9" | 2.1" | 2.1" | 1.6" | __ | 230V AC | __ | 0000000 | 000000 |
0.25" Quick-Disconnect Terminals | ||||||||||||||
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 24V AC | __ | 0000000 | 00000 |
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 120V AC | __ | 0000000 | 00000 |
H | No | Up | 6 | 2" | __ | __ | __ | __ | 1.3" | 2.4" | 230V AC | __ | 0000000 | 00000 |
J | No | Up | 5 | 2" | __ | __ | __ | __ | 2" | 2.3" | 8-32V DC | __ | 0000000 | 00000 |
M | No | Up | 6 | 2.1" | __ | __ | __ | __ | 0.6" | 2.3" | 15-75V AC, 9-60V DC | __ | 0000000 | 00000 |
M | No | Up | 6 | 2.1" | __ | __ | __ | __ | 0.6" | 2.3" | 75-270V AC, 36-185V DC | __ | 0000000 | 00000 |
Clip | ||||||||||||||
0.25" Quick-Disconnect Terminals | ||||||||||||||
K | No | Up | 6 | 2" | __ | __ | __ | __ | 2" | 2.3" | 10-80V DC | __ | 0000000 | 00000 |
DIN-Rail-Mount Electrically Actuated Hour Meters

Quickly install these meters onto a DIN rail instead of on a surface or into panels. Use them to display running time on a machine so you can schedule preventative maintenance. They are non-resettable to prevent tampering and accidental loss of data.
Electrically Actuated Hour Meters with Output Relay

Display running time on a machine so you can schedule preventative maintenance. These counters have two displays. One display shows the total running time and cannot be reset; the other shows the time elapsed since the last maintenance and can be wired for remote reset. The output relay turns on an indicator light and sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | No. of Set Points | For Panel Cutout Dia. | Dp. | Dia. | Operating Voltage | Output Relay Current | Environmental Rating | Each | |
Press On | |||||||||||
Wire Leads | |||||||||||
No | Up | 6 | 1 | 2" | 1.7" | 2.3" | 85-265V AC, 90-360V DC | 0.2 A @ 265 V AC, 0.2 A @ 40 V DC | IP67, NEMA 12, NEMA 4X | 00000000 | 0000000 |
No | Up | 6 | 1 | 2" | 1.7" | 2.3" | 10-40V DC | 0.2 A @ 265 V AC, 0.2 A @ 40 V DC | IP67, NEMA 12, NEMA 4X | 00000000 | 000000 |
Switch-Contact-Actuated Hour Meters

This meter does not require voltage to register a count. It is protected from dust, water, and splashing oil and coolant (meets IP65, NEMA 4X, NEMA 12). Use it to display running time on a machine so you can schedule preventative maintenance.
For Panel Cutout | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | Number of Digits | Ht. | Wd. | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Screw On | |||||||||||
Screw Terminals | |||||||||||
Yes | Up | 8 | 0.9" | 1.8" | 1" | 1.9" | 2.1" | IP65, NEMA 4X, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CE Marked | 00000000 | 000000 |
Electric-Motor-Actuated Hour Meters

With a sensor that’s activated by your electric motor’s magnetic field, these meters show the motor’s running time. To mount the meter sensor to your motor, use the adhesive back.
Non-resettable counter prevents tampering and accidental loss of data.
Resettable counter alerts the user when the count reaches a set point.
Vibration-Actuated Hour Meters



Record the running time of machines and vehicles that vibrate while operating. They are protected from dust and water (meets IP67). Counters are non-resettable to prevent tampering and accidental loss of data.
Electrically Actuated Minute Meters


Display running time on a machine so you can schedule preventative maintenance.
Non-resettable counter prevents tampering and accidental loss of data.
Preventative Maintenance and Inspection Indicators


Mount these indicators to your equipment, and their bright LED will catch your attention when it’s time for maintenance or inspection. They’re commonly used to keep track of maintenance on production lines and HVAC systems, or paired with inspection tags on fire extinguishers and eye wash stations.
When first set, these indicators flash a dark green and then a light green color every two minutes. As a scheduled inspection approaches, they flash a yellow light every 10 seconds. And when an inspection is past due, they blink red every two seconds. Reset indicators to start the countdown again. They meet IP65, so they seal out dust and low-pressure washdowns.
Timing Cycle | Resettable | Dia. | Ht. | Thick. | Batteries Included | Mounting Fasteners Included | Environmental Rating | Each | |
Screw On, Hang On, Tie On | |||||||||
---|---|---|---|---|---|---|---|---|---|
7 Day | Yes | 2 1/2" | 3 5/8" | 7/8" | Yes | Yes | IP65 | 000000 | 000000 |
30 Day | Yes | 2 1/2" | 3 5/8" | 7/8" | Yes | Yes | IP65 | 000000 | 00000 |
180 Day | Yes | 2 1/2" | 3 5/8" | 7/8" | Yes | Yes | IP65 | 000000 | 00000 |
365 Day | Yes | 2 1/2" | 3 5/8" | 7/8" | Yes | Yes | IP65 | 000000 | 00000 |
Counters/Hour Meters

Keep track of time while counting events. Units have two displays: one that receives input from a sensor, encoder, or switch and another that counts hours.
For technical drawings and 3-D models, click on a part number.